High sensitivity cardiac troponin assays in the clinical laboratories
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Immunoassays measuring cardiac troponins I or T have become firmly established as critical tools for diagnosing acute myocardial infarction. While most contemporary assays provide adequate diagnostic performance, the increased sensitivity and precision of the new, high sensitivity assays that have already been introduced into clinical practice, provide the potential to further shorten intervals between blood draws or the time needed to detect the first significant troponin elevation. In addition to the relatively modest benefits at the diagnostic end, the high sensitivity assays and the investigational ultrasensitive cardiac troponin assays offer improvements for predicting major adverse cardiovascular events, development of heart failure or transition to end-stage kidney disease. These novel high sensitivity assays can measure troponin concentrations in 50%–100% of healthy individuals and therefore allow for the distribution of troponin values within a healthy cohort to be measured, patient’s baseline troponin levels to be monitored, and clinicians to be alerted of deteriorating cardiorenal conditions. We envisage that the high sensitivity assays will become important tools for predicting each patient’s risk of future adverse events and for guiding and monitoring corresponding adjustments of preventative therapeutic interventions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Evidence for Cardiomyocyte Renewal in Humans
Bergmann, O., Bhardwaj, R. D., Bernard, S., Zdunek, S., Barnabé-Heider, F., Walsh, S., Zupicich, J., Alkass, K., Buchholz, B. A., Druid, H., et al. (2009) · Science · doi:10.1126/science.1164680 · Cited by 3,130 · cited 1×
“Recent data suggest that this process is rather slow, leading to a renewal of only approximately 40% of cardiac myocytes during one’s lifetime [16].”
Rissin, D. M., Kan, C. W., Campbell, T. G., Howes, S. C., Fournier, D. R., Song, L., Piech, T., Patel, P. P., Chang, L., Rivnak, A. J., et al. (2010) · Nature Biotechnology · doi:10.1038/nbt.1641 · Cited by 2,119 · cited 1×
“Quanterix introduced the term digital ELISA to describe this type of assay [35, 36].”
A trial of darbepoetin alfa in type 2 diabetes and chronic kidney disease
Pfeffer, M. A., Burdmann, E. A., Chen, C.-Y., Cooper, M. E., de Zeeuw, D., Eckardt, K.-U., Feyzi, J. M., Ivanovich, P., Kewalramani, R., Levey, A. S., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0907845 · Cited by 2,096
Antman, E. M., Tanasijevic, M. J., Thompson, B., Schactman, M., McCabe, C. H., Cannon, C. P., Fischer, G. A., Fung, A. Y., Thompson, C., Wybenga, D., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199610313351802 · Cited by 1,749
Analytical Characteristics of High-Sensitivity Cardiac Troponin Assays
Apple, F. S., Collinson, P. O., & for the IFCC Task Force on Clinical Applications of Cardiac Biomarkers (2012) · Clinical Chemistry · doi:10.1373/clinchem.2011.165795 · Cited by 861 · cited 1×
“The IFCC task force suggested in 2012 that in order to label a cTn assay as highly sensitive, cTn should be measurable in more than 50% of healthy subjects, and preferably in more than 95% [29].”
Fraser, C. G. (2012) · Clinical Chemistry and Laboratory Medicine · doi:10.1515/cclm.2011.733 · Cited by 286 · cited 3×
“An objective tool for the assessment of the significance of differences in serial results from an individual is provided by the reference change value (RCV) [53, 54].”
InfluentialDegradation of cardiac troponin I: implication for reliable immunodetection
Katrukha, A. G., Bereznikova, A. V., Filatov, V. L., Esakova, T. V., Kolosova, O. V., Pettersson, K., Lövgren, T., Bulargina, T. V., Trifonov, I. R., Gratsiansky, N. A., et al. (1998) · Clinical Chemistry · doi:10.1093/clinchem/44.12.2433 · Cited by 232 · cited 2×
“This may be due to several mechanisms – different stability of cTnI and cTnT in the circulation [17], impact of kidney function on cTn clearance [20], and potentially different ratios of free cTnI and cTnT pools in the cytoplasm of the damaged myocytes, which is all further complicated by different performance charact…”
Unstable Angina: Is It Time for a Requiem?
Braunwald, E., & Morrow, D. A. (2013) · Circulation · doi:10.1161/circulationaha.113.001258 · Cited by 226 · cited 1×
“However, due to the ls of the assay with LOD of 200 ng/L, more than 10 times the 99th percentile of today’s cTnT assays, it appears that the positive results were rather diagnostic for AMI than for UA, which itself is a rapidly disappearing disease entity [80].”
Counterpoint: Standardization of Cardiac Troponin I Assays Will Not Occur in My Lifetime
Apple, F. S. (2012) · Clinical Chemistry · doi:10.1373/clinchem.2011.166165 · Cited by 80 · cited 1×
“Multiple reasons why this effort is bound to fail were discussed by Apple who concluded that standardization of various cTnI assays is unlikely to happen anytime soon [38].”
Cited by
ATUALIZAÇÃO DA DIRETRIZ BRASILEIRA DE DISLIPIDEMIAS E PREVENÇÃO DA ATEROSCLEROSE - 2017
Faludi, A., Izar, M., Saraiva, J., Chacra, A., Bianco, H., Afiune Neto, A., Bertolami, A., Pereira, A., Lottenberg, A., Sposito, A., et al. (2017) · Arquivos Brasileiros de Cardiologia · doi:10.5935/abc.20170121 · Cited by 633
Clinical Use of High-Sensitivity Cardiac Troponin in Patients With Suspected Myocardial Infarction
Twerenbold, R., Boeddinghaus, J., Nestelberger, T., Wildi, K., Rubini Gimenez, M., Badertscher, P., & Mueller, C. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.07.718 · Cited by 255
“AB BR E V I A T I O N S AND ACRONYM S ACS = acute coronary syndrome ADP = advanced diagnostic pathway CAD = coronary artery disease CCTA = coronary computed tomography angiography cTn = cardiac troponin ECG = electrocardiogram ED = emergency department ESC = European Society of Cardiology FDA = Food and Drug Administr…”
BackgroundInfluentialSmith, J. G., & Gerszten, R. E. (2017) · Circulation · doi:10.1161/circulationaha.116.025446 · Cited by 206
Diaz-Garzon, J., Fernandez-Calle, P., Sandberg, S., Özcürümez, M., Bartlett, W. A., Coskun, A., Carobene, A., Perich, C., Simon, M., Marques, F., et al. (2021) · Clinical Chemistry · doi:10.1093/clinchem/hvaa261 · Cited by 42
The continuing evolution of cardiac troponin I biomarker analysis: from protein to proteoform
Soetkamp, D., Raedschelders, K., Mastali, M., Sobhani, K., Bairey Merz, C. N., & Van Eyk, J. (2017) · Expert Review of Proteomics · doi:10.1080/14789450.2017.1387054 · Cited by 36
“Singulex achieved ultra-high-sensitivity by conjugating the capture antibodies to paramagnetic particles followed by cTnI analysis using quantitative single molecule flow cytometry [42].”
Method
Metadata
- Authors
- Jarolim, P.
- Venue
- Clinical Chemistry and Laboratory Medicine (CCLM)
- Publisher
- Walter de Gruyter GmbH
- Published
- 2015-01-01
- Volume
- 53
- Issue
- 5
- Pages
- 635-52
- ISSN
- 1434-6621 (ISSN-L)
- 1437-4331
- OpenAlex
- W2128949406
- Cited by
- 139
- References
- 9
- FWCI
- 9.27
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High sensitivity cardiac troponin assays in the clinical laboratories. https://app.cochat.ai/papers/10.1515/cclm-2014-0565
- The paper
- Jarolim, P. (2015). High sensitivity cardiac troponin assays in the clinical laboratories. Clinical Chemistry and Laboratory Medicine (CCLM). https://doi.org/10.1515/cclm-2014-0565
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.