CoChat

Reliability of biological variation data available in an online database: need for improvement

Open access
Carobene, Anna · 2015 · Clinical Chemistry and Laboratory Medicine (CCLM)

The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.

Abstract

Biological variation (BV) data enable assessment of the significance of changes in serial measurements observed within a subject and are used to set analytical quality specifications. This data is available in a database held in Westgard website ( The BV data currently hosted on the Westgard website was examined. Distribution of measurands stratified by the number of cited references upon which the database entry is based and the distribution of papers stratified by publication year, are shown. Moreover, BV data available in literature for glycated hemoglobin, C-reactive protein, glycated albumin, alanine aminotransferase, aspartate aminotransferase and γ-glutamyl transferase are evaluated. The results obtained show that most BV data come just from a few papers or only one paper and that a lot of publications are dated, therefore this data is too obsolete to be used. Furthermore critical review of the BV database highlights a number of factors that might impact on the reliability of the BV data entries and translation into current practice. A number of issues clearly undermine the value of the current database. These issues are being considered by the European Federation of Clinical Chemistry and Laboratory Medicine, biological variation working group, in collaboration with a Spanish group responsible for the database updating.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1515/cclm-2014-1133

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 25 references

Research works printed but not linked: 23

  1. Braga, 2012, Biological variability of reactive protein is the available information reliable, Clin Chim Acta, 413
  2. Montagnana, 2013, Evaluation of biological variation of glycated albumin and fructosamine in healthy subjects, Clin Chim Acta, 423
  3. Schumann, 2002, IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at degrees International Federation of Clinical Chemistry and Laboratory Part Reference procedure for the measurement of catalytic concentration of, Medicine Clin Chem Lab Med, 37
  4. Carobene A, Braga F, Roraas T, Sandberg S, Bartlett WA. A systematic review of data on biological variation for alanine aminotransferase, aspartate aminotransferase and γ-glutamyl transferase. Clin Chem Lab Med 2013;51:1997-2007. · DOI · Paper page
  5. Braga F, Panteghini M. Biological variability of C-reactive protein: is the available information reliable? Clin Chim Acta 2012;413:1179-83.
  6. Miller GW, Bruns DE, Hortin GL, Sandberg S, Aakre KM, McQueen MJ, et al. Current issues in measurement and reporting of urinary albumin excretion. Clin Chem 2009;55:24-38. · DOI · Paper page
  7. Schumann G, Bonora R, Ceriotti F, Férard G, Ferrero CA, Frank PF, et al. IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C. International Federation of Clinical Chemistry and Laboratory Medicine. Part 6. Reference procedure for the measurement of catalytic concentration of γ-glutamyltransferase. Clin Chem Lab Med 2002;40:734-8.
  8. Bartlett, checklist for critical appraisal of studies of biological variation, Clin Chem Lab Med, 2015
  9. Schumann G, Bonora R, Ceriotti F, Férard G, Ferrero CA, Frank PF, et al. IFCC primary reference procedures for the measurement of catalytic activity concentrations of enzymes at 37 degrees C. International Federation of Clinical Chemistry and Laboratory Medicine. Part 5. Reference procedure for the measurement of catalytic concentration of aspartate aminotransferase. Clin Chem Lab Med 2002;40:725-33.
  10. Lenters-Westra E, Roraas T, Schindhelm RK, Slingerland RJ, Sandberg S. Biological variation of hemoglobin A1c: con- sequences for diagnosing diabetes mellitus. Clin Chem 2014;60:1570-2. · DOI
  11. Pagani F, Panteghini M. Biological variation in serum activities of three hepatic enzymes. Clin Chem 2001;47:355-6. · DOI
  12. Fraser CG. Biological variation in clinical chemistry. Arch Pathol Lab Med 1992;116:916-23.
  13. Ricos, 1999, Current databases on biological variation pros cons progress, Clin Lab Invest, 59
  14. Fraser, 1989, Generation and application of data on biological variation in clinical chemistry, Crit Rev Clin Lab Sci, 27, 409, 10.3109/10408368909106595 · DOI · Paper page
  15. Roraas T, Hyltoft Petersen P, Sandberg S. CIs and power calculations for within-person biological variation: effect of analytical imprecision, number of replicates, number of samples, and number of individuals. Clin Chem 2012;58: 1306-13.
  16. Perich, Biological variation database : structure and criteria used for generation and update, Clin Chem Lab Med, 2015
  17. Plebani, Biological variation back to basics, Clin Chem Lab Med, 2015
  18. Davie SJ, Whiting KL, Gould BJ. Biological variation in glycated proteins. Ann Clin Biochem 1993;30:260-4. · DOI
  19. Fraser, 1992, Biological variation in clinical chemistry, Arch Pathol Lab Med, 23, 116
  20. Cooper, 2010, Collective opinion paper on finding of the convocation of experts on laboratory quality, Clin Chem Lab Med, 49
  21. Simundic, Biological variation a still evolving facet of laboratory pt, AM medicine Ann Clin Biochem, 2015
  22. Fraser, 2009, Reference change values the way forward in monitoring, Ann Clin Biochem, 264, 10.1258/acb.2009.009006 · DOI
  23. Aasne, Biological variation reliable data is essential, Clin Chem Lab Med, 2015

Cited by

Metadata

Authors
Carobene, A.
Affiliations
IRCCS Ospedale San Raffaele (IT)
Corresponding author
Carobene, Anna
Venue
Clinical Chemistry and Laboratory Medicine (CCLM)
Published
2015-01-01
Volume
53
Issue
6
Pages
871-7
ISSN
  • 1434-6621 (ISSN-L)
  • 1437-4331
OpenAlex
W2034565110
Cited by
76
References
25
Citations by year
2026: 3 · 2025: 2 · 2024: 4 · 2023: 4 · 2022: 7 · 2021: 9 · 2020: 10 · 2019: 7 · 2018: 14 · 2017: 9 · 2016: 4 · 2015: 3
FWCI
7.36
Type
journal article
Language
en
Open access
Locations
  • Clinical Chemistry and Laboratory Medicine (CCLM) (publishedVersion)
  • PubMed (publishedVersion)
  • INFM-OAR (INFN Catania) (submittedVersion, other-oa)
Topics
  • Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
  • Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
  • Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
Keywords
biological variation, within-person variability, HbA1c, C-reactive protein, glycated albumin, alanine aminotransferase, aspartate aminotransferase, gamma-glutamyl transferase
MeSH terms
Glycated Serum Albumin, Alanine Transaminase, Aspartate Aminotransferases, Biological Assay, C-Reactive Protein, gamma-Glutamyltransferase, Glycated Hemoglobin, Humans, Reference Values, Serum Albumin, Observer Variation, Databases, Factual, Glycation End Products, Advanced, Internet

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.