CoChat

Immunoassay or LC-MS/MS for the measurement of salivary cortisol in children?

Bae, Yoon Ju, Gaudl, Alexander, Jaeger, Sonia, Stadelmann, Stephanie, Hiemisch, Andreas, Kiess, Wieland, Willenberg, Anja, Schaab, Michael, von Klitzing, Kai, Thiery, Joachim, Ceglarek, Uta, Döhnert, Mirko, Kratzsch, Juergen · 2016 · Clinical Chemistry and Laboratory Medicine (CCLM)
Cited by 62

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

Background: Dysregulation of the adrenal cortex has been assessed with measurement of salivary cortisol. So far salivary cortisol is routinely measured with immunoassay (IA). However, liquid chromatography-tandem mass spectrometry (MS) is known to offer better specificity. We compared the concentrations of salivary cortisol measured by MS and IA at basal and stress induced conditions and evaluated reasons for the difference in method-dependent cortisol results. Methods: Saliva samples (n=2703) were collected from 169 children (age range: 8–14 years; 81 healthy children; 55 with internalizing and 33 with externalizing disorders) under circadian conditions and during the Trier Social Stress Test for Children (TSST-C). Biochemical analyses were performed with MS for cortisol and cortisone, IA (IBL, RE62011) for cortisol, and enzyme kinetic assay for α-amylase. Results: MS and IA showed mostly comparable results for circadian activity and TSST-C response with similar statistical power. However, IA measured cortisol concentrations about 2.39-fold higher than MS. We found that this difference in measured values between MS and IA was mainly due to different standardization of IA compared to MS. In addition, at cortisol IA concentration below 5 nmol/L, cross-reactivity with cortisone was found to contribute to the lower concordance between MS and IA. Conclusions: Immunoassay and LC-MS/MS were largely comparable in the interpretation of salivary cortisol dynamics in stress research. But the IA method revealed a restricted accuracy in the measuring range below 5 nmol/L.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1515/cclm-2015-0412

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

See all 62

Metadata

Authors
Bae, Y. J., Gaudl, A., Jaeger, S., Stadelmann, S., Hiemisch, A., Kiess, W., Willenberg, A., Schaab, M., von Klitzing, K., Thiery, J., Ceglarek, U., Döhnert, M., & Kratzsch, J.
Venue
Clinical Chemistry and Laboratory Medicine (CCLM)
Published
2016-01-01
Volume
54
Issue
5
Pages
811-22
ISSN
  • 1434-6621 (ISSN-L)
  • 1437-4331
OpenAlex
W2337121016
Cited by
62
References
12
FWCI
2.13
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Immunoassay or LC-MS/MS for the measurement of salivary cortisol in children? https://app.cochat.ai/papers/10.1515/cclm-2015-0412
The paper
Bae, Y. J., Gaudl, A., Jaeger, S., Stadelmann, S., Hiemisch, A., Kiess, W., Willenberg, A., Schaab, M., von Klitzing, K., Thiery, J., Ceglarek, U., Döhnert, M., & Kratzsch, J. (2016). Immunoassay or LC-MS/MS for the measurement of salivary cortisol in children? Clinical Chemistry and Laboratory Medicine (CCLM). https://doi.org/10.1515/cclm-2015-0412

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.