Order of blood draw: Opinion Paper by the European Federation for Clinical Chemistry and Laboratory Medicine (EFLM) Working Group for the Preanalytical Phase (WG-PRE)
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
It has been well reported over recent years that most errors within the total testing process occur in the pre-analytical phase (46%–68.2%), an area that is usually outside of the direct control of the laboratory and which includes sample collection (phlebotomy). National and international (WHO, CLSI) guidelines recommend that the order of draw of blood during phlebotomy should be blood culture/sterile tubes, then plain tubes/gel tubes, then tubes containing additives. This prevents contamination of sample tubes with additives from previous tubes that could cause erroneous results. There have been a number of studies recently looking at whether order of draw remains a problem with modern phlebotomy techniques and materials, or it is an outdated practice followed simply because of historical reasons. In the following article, the European Federation of Clinical Chemistry and Laboratory Medicine Working Group for the Preanalytical Phase (EFLM WG-PRE) provides an overview and summary of the literature with regards to order of draw in venous blood collection. Given the evidence presented in this article, the EFLM WG-PRE herein concludes that a significant frequency of sample contamination does occur if order of draw is not followed during blood collection and when performing venipuncture under less than ideal circumstances, thus putting patient safety at risk. Moreover, given that order of draw is not difficult to follow and knowing that ideal phlebotomy conditions and protocols are not always followed or possible, EFLM WG-PRE supports the continued recommendation of ensuring a correct order of draw for venous blood collection.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The text we found for this paper looks like another document, so the self-check wasn’t run.
Citations
Cites
Errors in a Stat Laboratory: Types and Frequencies 10 Years Later
Carraro, P., & Plebani, M. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2007.088344 · Cited by 670
Mistakes in a stat laboratory: types and frequency
Plebani, M., & Carraro, P. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.8.1348 · Cited by 572
The Brain-to-Brain Loop Concept for Laboratory Testing 40 Years After Its Introduction
Plebani, M., Laposata, M., & Lundberg, G. D. (2011) · American Journal of Clinical Pathology · doi:10.1309/ajcpr28hwhssdnon · Cited by 212
Medical errors: impact on clinical laboratories and other critical areas
Kalra, J. (2004) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2004.08.009 · Cited by 168
Quantitative Chemical Analysis
Li, N., Hefferren, J. J., & Li, K. (2013) · WORLD SCIENTIFIC eBooks · doi:10.1142/8727 · Cited by 100
Simundic, A.-M., Church, S., Cornes, M. P., Grankvist, K., Lippi, G., Nybo, M., Nikolac, N., van Dongen-Lases, E., Eker, P., Kovalevskaya, S., et al. (2015) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2014-1053 · Cited by 95
Self-citationSpurious hyperkalaemia due to EDTA contamination: common and not always easy to identify
Cornes, M. P., Ford, C., & Gama, R. (2008) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1258/acb.2008.007241 · Cited by 69 · cited 1×
“The first measured EDTA levels in all hyperkalaemic samples and the second measured EDTA in all hypomagnesaemic, hypocalcaemic and hypozincaenic samples over a 1 month period [21, 22].”
BackgroundSelf-citationSharratt, C. L., Gilbert, C. J., Cornes, M. C., Ford, C., & Gama, R. (2009) · International Journal of Clinical Practice · doi:10.1111/j.1742-1241.2008.01981.x · Cited by 66 · cited 1×
“The first measured EDTA levels in all hyperkalaemic samples and the second measured EDTA in all hypomagnesaemic, hypocalcaemic and hypozincaenic samples over a 1 month period [21, 22].”
BackgroundSelf-citationRecommended "order of draw" for collecting blood specimens into additive-containing tubes.
Calam, R. R., & Cooper, M. H. (1982) · Clinical Chemistry · doi:10.1093/clinchem/28.6.1399 · Cited by 47
The order of draw: myth or science?
Salvagno, G., Lima-Oliveira, G., Brocco, G., Danese, E., Guidi, G. C., & Lippi, G. (2013) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2013-0412 · Cited by 42
Self-citation
Cited by
Joint EFLM-COLABIOCLI Recommendation for venous blood sampling
Simundic, A.-M., Bölenius, K., Cadamuro, J., Church, S., Cornes, M. P., van Dongen-Lases, E. C., Eker, P., Erdeljanovic, T., Grankvist, K., Guimaraes, J. T., et al. (2018) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2018-0602 · Cited by 240
Self-citationPre-analytical issues in the haemostasis laboratory: guidance for the clinical laboratories
Magnette, A., Chatelain, M., Chatelain, B., Ten Cate, H., & Mullier, F. (2016) · Thrombosis Journal · doi:10.1186/s12959-016-0123-z · Cited by 166
Lippi, G., von Meyer, A., Cadamuro, J., & Simundic, A.-M. (2019) · Diagnosis · doi:10.1515/dx-2018-0018 · Cited by 135
Self-citationLima-Oliveira, G., Volanski, W., Lippi, G., Picheth, G., & Guidi, G. C. (2017) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2017.1295317 · Cited by 117
Self-citationBlood venous sample collection: Recommendations overview and a checklist to improve quality
Giavarina, D., & Lippi, G. (2017) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2017.02.021 · Cited by 136
Self-citationKitchen, S., Adcock, D. M., Dauer, R., Kristoffersen, A., Lippi, G., Mackie, I. J., Marlar, R. A., & Nair, S. C. (2021) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.13702 · Cited by 104
Self-citationThe EFLM strategy for harmonization of the preanalytical phase
Lippi, G., & Šimundić, A.-M. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2017-0277 · Cited by 90
Self-citationKitchen, S., Adcock, D. M., Dauer, R., Kristoffersen, A., Lippi, G., Mackie, I. J., Marlar, R. A., & Nair, S. C. (2021) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.13584 · Cited by 58
Self-citationHarmonization in laboratory medicine: more than clinical chemistry?
Plebani, M. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2017-0865 · Cited by 55
Lippi, G., Baird, G. S., Banfi, G., Bölenius, K., Cadamuro, J., Church, S., Cornes, M. P., Dacey, A., Guillon, A., HOFFMANN, G. E., et al. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2017-0107 · Cited by 53
Self-citationNUMBER: standardized reference intervals in the Netherlands using a ‘big data’ approach
den Elzen, W. P. J., Brouwer, N., Thelen, M., le Cessie, S., Haagen, I.-A., & Cobbaert, C. M. (2018) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2018-0462 · Cited by 41
Joint EFLM-COLABIOCLI recommendation for venous blood sampling
Šimundić, A.-M., Bölenius, K., Cadamuro, J., Church, S., Cornes, M. P., van Dongen-Lases, E. C., Eker, P., Erdeljanovic, T., Grankvist, K., Guimarães, J. T., et al. (2019) · Annales de biologie clinique · doi:10.1684/abc.2019.1419 · Cited by 40
Self-citationBlood sampling guidelines with focus on patient safety and identification – a review
Cornes, M. P., Ibarz, M., Ivanov, H., & Grankvist, K. (2018) · Diagnosis · doi:10.1515/dx-2018-0042 · Cited by 42
Self-citationThe preanalytical phase – from an instrument-centred to a patient-centred laboratory medicine
Cadamuro, J., & Šimundić, A.-M. (2022) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2022-1036 · Cited by 36
Zimmerman, F. S., Karameh, H., Ben‐Chetrit, E., Zalut, T., Assous, M. V., & Levin, P. D. (2019) · Clinical Infectious Diseases · doi:10.1093/cid/ciz971 · Cited by 28
The preanalytical phase – Past, present and future
Cornes, M. P. (2019) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/0004563219867989 · Cited by 28
Self-citationRundgren, I. M., Bruserud, Ø., Ryningen, A., & Ersvær, E. (2018) · Journal of Immunological Methods · doi:10.1016/j.jim.2018.06.003 · Cited by 23
Chang, J., Choi, S., Cho, H., Kim, S., Chung, J., Yoo, S. J., Song, E. Y., & Chun, S. (2025) · Annals of Laboratory Medicine · doi:10.3343/alm.2025.0022 · Cited by 20
Quality in laboratory medicine and the Journal: walking together
Plebani, M. (2022) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2022-0755 · Cited by 20
The Order of Draw during Blood Collection: A Systematic Literature Review
Bazzano, G., Galazzi, A., Giusti, G. D., Panigada, M., & Laquintana, D. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph18041568 · Cited by 24
Exogenous sample contamination. Sources and interference
Cornes, M. P. (2016) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2016.09.014 · Cited by 20
Self-citationIntroduction to Comparative Clinical Pathology
Stacy, N. I., Hollinger, C., & Hooijberg, E. H. (2018) · Elsevier eBooks · doi:10.1016/b978-0-443-18437-6.00033-x · Cited by 15
Cai, Q., Zhou, Y., & Yang, D. (2017) · Biochemia Medica · doi:10.11613/bm.2018.010703 · Cited by 14
Ercan, Ş., Ramadan, B., & Gerenli, O. (2021) · Biochemia Medica · doi:10.11613/bm.2021.020704 · Cited by 13
Indirect determination of biochemistry reference intervals using outpatient data
Martínez-Sánchez, L. M., Cobbaert, C. M., Noordam, R., Brouwer, N., Blanco‐Grau, A., Villena-Ortiz, Y., Thelen, M., Ferrer, R., Casís, E., Rodríguez‐Frias, F., et al. (2022) · PLoS ONE · doi:10.1371/journal.pone.0268522 · Cited by 13
Saračević, A., Dukić, L., Juričić, G., Kopčinović, L. M., Mirošević, G., & Šimundić, A.-M. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2017-0279 · Cited by 13
A national survey of specimen contamination in the UK
Logie, J. J., & Chaloner, C. (2018) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/0004563218812500 · Cited by 11
Standard-Arbeitsanleitung zur peripher venösen Blutentnahme für die labormedizinische Diagnostik
Meyer, A., Cadamuro, J., Streichert, T., Gurr, E., Fiedler, M., Leichtle, A. B., Petersmann, A., Pick, K.-H., Orth, M., Risch, L., et al. (2017) · Journal of Laboratory Medicine · doi:10.1515/labmed-2017-0127 · Cited by 21
An overview of EFLM harmonization activities in Europe
Kilpatrick, E. S., & Sandberg, S. (2018) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2018-0098 · Cited by 11
Kulkarni, K. K., Bhandari, A. P., & Unni, A. K. (2020) · Journal of Laboratory Physicians · doi:10.1055/s-0040-1720945 · Cited by 12
Jacobsen, K. K., Brandt, I., Christensen, A. V., Rimsø, B. A., Krøier, C. J., Sørensen, M., Smith, J. S., Jensen, K. O. F., & Larsen, J. M. (2018) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2018.04.020 · Cited by 9
Heparin and citrate additive carryover during blood collection
Keppel, M. H., Auer, S., Lippi, G., Meyer, A., Cornes, M. P., Felder, T. K., Oberkofler, H., Mrazek, C., Haschke‐Becher, E., & Cadamuro, J. (2019) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2019-0433 · Cited by 10
Self-citationCase report of unexplained hypocalcaemia in a slightly haemolysed sample
Cornes, M. (2017) · Biochemia Medica · doi:10.11613/bm.2017.046 · Cited by 7
Self-citationPre-analytical errors in coagulation testing: a case series
Mahto, M., Kumar, V., Banerjee, A., Kumar, S., & Kumar, A. (2023) · Diagnosis · doi:10.1515/dx-2023-0110 · Cited by 7
Unveiling the hidden clinical and economic impact of preanalytical errors
Lippi, G. (2025) · Turkish Journal of Biochemistry · doi:10.1515/tjb-2025-0196 · Cited by 8
Self-citationPreanalytical potassium EDTA sample contamination: open versus closed phlebotomy systems
Asif, U., Whitehead, S. J., Ford, C., & Gama, R. M. (2019) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/0004563219878463 · Cited by 9
Lopez, G. I., Serruya, R. A., Barchuk, M., Gaitán-Charry, D., Torres‐Leal, F. L., Moreno, L. A., Delgado, C., Carvalho, H. B., de Moraes, A. C. F., & Berg, G. A. (2020) · Scientific Reports · doi:10.1038/s41598-020-57457-1 · Cited by 7
The role of AI in pre-analytical phase – use cases
Çubukçu, H. C. (2025) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2025-1220 · Cited by 6
Dey, S., Rai, N., Bansal, A., Kumari, B., Das, B., & Kumari, A. (2023) · Cureus · doi:10.7759/cureus.50372 · Cited by 6
Mankar, P. D., Hatgaonkar, K., Kohale, M., Wankhade, R., & Bandre, G. R. (2024) · Journal of Applied Hematology · doi:10.4103/joah.joah_3_24 · Cited by 6
The effects of transport by car on coagulation tests
Ergin, M., Erdoğan, S., Aktürk, O., & Erel, O. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2016-0824 · Cited by 6
Hemostasis Testing in the Emergency Department: A Narrative Review
Thonon, H., Nieuwenhove, M. V., Thachil, J. V., Lippi, G., Hardy, M. J., & Mullier, F. (2024) · Seminars in Thrombosis and Hemostasis · doi:10.1055/s-0044-1787661 · Cited by 8
Self-citationPre-analytical Phase in Hemostasis: The Main Anomalies and Means to Correct Them
Khayati, S., Ikhlas, M., Bahri, R., Zineb, A. S. A., Yahyaoui, H., Mustapha, A. A., & Chakour, M. (2019) · American Journal of Laboratory Medicine · doi:10.11648/j.ajlm.20190406.14 · Cited by 5
Kovalevskaya, S., Gilmanov, A. Z., Zybina, N. N., Алексеевна, К. Н., & Emanuel, V. L. (2023) · Laboratory Service · doi:10.17116/labs20231201133 · Cited by 4
Demonte, D., Pucci, M., Salvagno, G. L., & Lippi, G. (2019) · Diagnosis · doi:10.1515/dx-2019-0027 · Cited by 4
Self-citationBayot, M. L., & Tadi, P. K. R. (2021) · StatPearls · Cited by 4
Favaloro, E. J., Pasalic, L., & Lippi, G. (2024) · Polskie Archiwum Medycyny Wewnętrznej · doi:10.20452/pamw.16684 · Cited by 3
Self-citationDhankhar, A., Khobragade, P. Y., Banerjee, J., Chopra, G., Jacob, S., Dey, A. B., Lee, J., Crimmins, E. M., Thyagarajan, B., Dey, S., et al. (2025) · PLoS ONE · doi:10.1371/journal.pone.0326917 · Cited by 3
Gojković, T., Vladimirov, S. S., Antonić, T., Bogavac‐Stanojević, N., Novović, K., Spasojević‐Kalimanovska, V., & Filipić, B. (2023) · Journal of Medical Biochemistry · doi:10.5937/jomb0-40360 · Cited by 2
Prevention of Clinical Laboratory Test Error: Pre-analytical Error
Vongsakulyanon, A. (2019) · Ramathibodi Medical Journal · doi:10.33165/rmj.2019.42.2.142535 · Cited by 2
Wspólne zalecenia EFLM-COLABIOCLI dotyczące pobierania krwi żylnej
Šimundić, A.-M., Bölenius, K., Cadamuro, J., Church, S., Cornes, M. P., van Dongen-Lases, E. C., Eker, P., Erdeljanovic, T., Grankvist, K., Guimarães, J. T., et al. (2019) · Diagnostyka Laboratoryjna · doi:10.5604/01.3001.0013.7785 · Cited by 2
Self-citationPractical recommendations for taking venous blood samples for laboratory tests
Redaktsiia (2022) · Laboratory Service · doi:10.17116/labs20221104154 · Cited by 5
Giavarina, D. (2023) · Springer eBooks · doi:10.1007/978-3-031-24958-7_6 · Cited by 2
Pseudohyperkalemia Caused by EDTA Contamination: a Not Uncommon Pre-analytical Error
Laiwejpithaya, S. (2019) · Siriraj Medical Journal/San Sirirat · doi:10.33192/smj.2019.49 · Cited by 3
Patel, K. P., Carval, T., Poojary, A. A., & Poojary, R. A. (2019) · Journal of Patient Safety & Infection Control · doi:10.4103/jpsic.jpsic_25_19 · Cited by 2
Influence of Pre-Analytic Conditions on Quantity of Lymphocytes
Proschmann, U., Amirkhiz, P. S., Andres, P., Haase, R., Inojosa, H., Ziemssen, T., & Akgün, K. (2023) · International Journal of Molecular Sciences · doi:10.3390/ijms241713479 · Cited by 1
Issues in the Preanalytical Process of Specimens for Laboratory Tests in Home Healthcare Settings
Shimizu, N., & Kotani, K. (2026) · Healthcare · doi:10.3390/healthcare14121749 · Cited by 1
Pediatric Phlebotomy: Taking the Bite Out of Dracula
Normandin, P. A., & Benotti, S. A. (2018) · Journal of Emergency Nursing · doi:10.1016/j.jen.2018.03.017 · Cited by 1
Unexpected abnormal coagulation test results in a 2-year-old child: A case report
Radovanović, P. B., Mikulčić, T. Ž., & Medica, J. S. (2019) · Biochemia Medica · doi:10.11613/bm.2020.011002 · Cited by 1
A survey of order of draw on inpatient wards and adherence to EFLM-COLABIOCLI recommendations
Hepburn, S. (2020) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2020-0202 · Cited by 1
Yeates, R. L. (2016) · ResearchOnline at James Cook University (James Cook University) · doi:10.25903/s7je-hm44 · Cited by 1
Ibarz, M., & Rioja, R. G. (2019) · Revista del Laboratorio Clínico · doi:10.1016/j.labcli.2019.02.001 · Cited by 1
Self-citationImpact of specific preclinical variables on coagulation biomarkers in cancer-associated thrombosis
Selby, R., Duffy, E. R., Berny‐Lang, M. A., Andry, C., & Lee, A. Y. Y. (2020) · Thrombosis Research · doi:10.1016/s0049-3848(20)30393-5
John, J., Dharwadkar, K., & Jini, M. P. (2020) · International Journal of Community Medicine and Public Health · doi:10.18203/2394-6040.ijcmph20203923
Analysis of preanalytical phase errors in a medical diagnostic laboratory
Rak-Pasikowska, A., Goniwiecha, D., & Bil‐Lula, I. (2019) · Diagnostyka Laboratoryjna · doi:10.5604/01.3001.0013.7440
Importancia de la fase preanalítica para el laboratorio clínico
Alonso-Rodríguez, C. Á. (2021) · Acta Médica · Cited by 14
Factors Associated with Variation
Qin, X. Y. (2021) · Springer eBooks · doi:10.1007/978-981-16-1037-0_7
Recommendations for safe collection of venous blood by a closed collection system
Bolerázska, B., Birková, A., Čižmárová, B., & Hubková, B. (2021) · Vnitřní lékařství · doi:10.36290/vnl.2021.114
Silveira, Z. P., Henriques, A. M. A., Costa, F. B., Carcuchinski, A. P. N., da Silva, F. G., Pires, I. D. S., & Lunardi, L. S. (2022) · doi:10.22533/at.ed.7572219083
TRANSTORNO DO PÂNICO E ANSIEDADE: UM RELATO DE CASO
Miranda, J. P. L., Trindade, J. P. M., Matsuda, M. H., de Leão, M. A. L., Wood, P. C., Sáber, M. D. S. C., dos Santos, J. B., & Cury, J. G. D. M. (2022) · doi:10.22533/at.ed.75722190810
de Morais, V. G., Guareschi, S., Machado, R. A. A., Dourado, T. L., Filho, F. D. A., Silva, M. C. D. M., Ribeiro, W. J., Maranhão, M. G. M., Filho, A. B. D. C., Rodrigues, S. P., et al. (2022) · doi:10.22533/at.ed.7572219087
Silveira, Z. P., Henriques, A. M. A., D’Avila, D. O., Noro, A., de Cezaro, P., Reyes, V. B., Fernandes, A. P. W., Pires, I. D. S., Borges, C. T., & Lunardi, L. S. (2022) · doi:10.22533/at.ed.7572219086
Melo, M. A. D. S., de Castro, A. M., Coleta, M. F. D., Coleta, J. A. D., Bezerra, J. C. B., Gomes, D. B., Melo, A. L. D. S., Alves, A. L., Lima, P., de Melo, B. M., et al. (2022) · doi:10.22533/at.ed.7572219085
CITOLOGIA ONCÓTICA: FATORES QUE OCASIONAM A NÃO ADESÃO DAS MULHERES AO EXAME
Maximiano, L. C. D. S., Nunes, M. J. M., Marcos, G. V. T. D. M., Barrozo, L. C. P., Sinezio, P. R. A. D. O., Duarte, K. I. S., Silva, S. M. F. E., Leite, J. S., Batista, E. R., Oliveira, M. L. D. M., et al. (2022) · doi:10.22533/at.ed.7572219089
A PARALISIA INFANTIL E SUAS CONSEQUÊNCIAS PSICOSSOCIAIS NO IDOSO, ASSOCIADO A INSTITUCIONALIZAÇÃO
do Prado, M. C. G., Domingues, L. J., Migliorini, N., dos Santos, J. B., & Cury, J. G. D. M. (2022) · doi:10.22533/at.ed.7572219084
REAÇÕES ALÉRGICAS E TESTE CUTÂNEO DE DIAGNÓSTICO
Alves, R. D. A. N., Bertoluci, M. E. F., PAGANUCCI, V. V. D. C., Alves, C. D. A. N., dos Santos, J. B., & Cury, J. G. D. M. (2022) · doi:10.22533/at.ed.75722190814
PERFIL DE PACIENTES COM DIAGNÓSTICO DE HANSENÍASE NO ESTADO DA BAHIA
Ferreira, A. C., Ferreira, I. J. M., Costa, K. I. D. B., Moreira, C. N., & Amorim, J. D. S. (2022) · doi:10.22533/at.ed.75722190817
PERFIL EPIDEMIOLÓGICO DA HANSENÍASE NA IX REGIÃO DE SAÚDE DE PERNAMBUCO
de Noronha, R. B., Campos, P. E. D. S., de Freitas, C. B., da Silva, J. W. F., Nunes, S. P., Ferraz, A. C. D., de Brito, A. M. P., Delmondes, G. D. A., Barberino, M. L., & de Sá, S. M. (2022) · doi:10.22533/at.ed.75722190815
PANORAMA SÓCIO ETÁRIO E CULTURAL DA ENDOMETRIOSE NO ESTADO DE SÃO PAULO
de Freitas, T. R., de Freitas, S. R., Chavaglia, L. C. R., Romanello, T. B., Balseiro, L. M., Balseiro, E. M., & Trigo, Á. A. (2022) · doi:10.22533/at.ed.75722190816
de Morais, V. G., Ribeiro, W. J., Oliveira, S. M., Machado, R. A. A., Maranhão, M. G. M., de Jesus, R. C., Piveta, C. K., Balena, G. Z., Braga, G. W. D. A., Cruvinel, D. R. V., et al. (2022) · doi:10.22533/at.ed.7572219082
RELATO DE CASO: VARIZES E O TRATAMENTO COM ESCLEROTERAPIA E A ADESÃO TERAPÊUTICA
Marcondes, L. F., Grando, L. S., Marçal, B. B., dos Santos, J. B., & Cury, J. G. D. M. (2022) · doi:10.22533/at.ed.75722190812
RELATO DE CASO: DIAGNÓSTICO DE SÍNDROME METABÓLICA E COMORBIDADES ASSOCIADAS
de Leão, M. A. L., Wood, P. C., Sáber, M. D. S. C., Dotta, R. P., Miranda, J. P. L., Trindade, J. P. M., dos Santos, J. B., & Cury, J. G. D. M. (2022) · doi:10.22533/at.ed.75722190813
SITUAÇÃO DE SAÚDE DE MANACAPURU, AMAZÔNIA: UM EXERCÍCIO DE ANÁLISE
Rocha, A. P. D. A., Santos, G. V. P., Cisneros, N. T., Corrêa, V. V. P., Leite, H. N. F., & Leite, L. R. B. (2022) · doi:10.22533/at.ed.75722190811
ASSISTÊNCIA EM HIV/AIDS NA ATENÇÃO BÁSICA: UM ESTUDO DA REDE DE RIO CLARO/SP
Peixoto, C., Bellenzani, R., Fioroni, L. N., Araújo, E. G., & Souto, B. G. A. (2022) · doi:10.22533/at.ed.7572219088
Dantas, B. V., Leite, H. C., Saavedra, C. B. B., da Silva, J. S., Querido, D. L., Esteves, A. P. V. D. S., Melo, M. M., de Souza, P. V., & de Almeida, V. S. (2022) · doi:10.22533/at.ed.7572219081
Mthethwa, B. T. (2023) · DUT Open Scholar (Durban University of Technology) · doi:10.51415/10321/4917
ใบพฤกษ์ทอง, ค., & สวนกระต่าย, ช. (2021) · Chula Digiverse · doi:10.58837/chula.the.2021.1133
Joint EFLM-COLABIOCLI recommendation for venous blood sampling - v 1.1, June 2018
Šimundić, A.-M., Bölenius, K., Cadamuro, J., Church, S., Cornes, M. P., van Dongen-Lases, E. C., Eker, P., Erdeljanovic, T., Grankvist, K., Guimarães, J. T., et al. (2024) · Revista română de medicină de laborator · doi:10.2478/rrlm-2024-0004 · Cited by 2
Self-citationPrevalence and detection of citrate contamination in clinical laboratory
Lorde, N., Gama, R. M., & Kalaria, T. (2025) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2024-1389
Specimen Handling Errors and Cbc Result Accuracy
Albeladi, A. A., Altasan, I. A., Alaboud, A. M., Aldaajani, W. T., & Alzahrani, R. A. (2024) · International Journal Of Health Care And Nursing · doi:10.55938/ijhcn.v3i1.198
Trakulkaseamsiri, S., & Chumchujan, K. (2025) · Journal of Associated Medical Sciences · doi:10.12982/jams.2026.005
The impact of age on the Na:K ratio: observations from a general canine population
Zemko, P., Bonsembiante, F., Canevelli, M., & Banzato, T. (2025) · Frontiers in Veterinary Science · doi:10.3389/fvets.2025.1629328
Zhang, R., Lin, Y., Chen, S., Zhang, K., Xu, P., Xiaomei, F., Liu, F., Zhi, X., & Zhang, Z. (2026) · Scientific Reports · doi:10.1038/s41598-026-40294-z
Biomarkers of Health and Disease in Veterinary Science, volume II
(2026) · Frontiers research topics · doi:10.3389/978-2-8325-7662-5
Laboratory Artifacts in Clinical Medicine: A Review
Kanjee, Z., Lippi, G., & Freed, J. A. (2026) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2026.04.009
Self-citationMachine learning for the identification of mild to moderate EDTA contamination of serum samples
Farrell, C.-J. L., Sherfan, J., & Badrick, T. C. (2026) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/00045632261488751
Gega, V., Doka, G., Alicka, Y., Cabiri, Z., Mëhilli, B., & Baushi, K. (2026) · Malque Health · doi:10.31893/health.2027004
Metadata
- Authors
- Cornes, M., van Dongen-Lases, E., Grankvist, K., Ibarz, M., Kristensen, G., Lippi, G., Nybo, M., & Simundic, A.-M.
- Affiliations
- The Royal Wolverhampton NHS Trust (GB)
- Department of Clinical Chemistry, Academic Medical Center, Amsterdam, The Netherlands
- Umeå University (SE)
- Laboratori Clínic Hospital Arnau de Vilanova, Lleida, Spain
- Norwegian Clinical Chemistry EQA Programme, Bergen, Norway
- University of Verona (IT)
- Odense University Hospital (DK)
- Department of Medical Laboratory Diagnostics, University Hospital Sveti Duh, Zagreb, Croatia
- Corresponding author
- Cornes, Michael
- Venue
- Clinical Chemistry and Laboratory Medicine (CCLM)
- Publisher
- Walter de Gruyter GmbH
- Published
- 2016-07-21
- Volume
- 55
- Issue
- 1
- Pages
- 27-31
- ISSN
- 1434-6621 (ISSN-L)
- 1437-4331
- OpenAlex
- W2479249860
- Semantic Scholar
- 2691ae319d1d8efc628f2da25f083605b574000a
- Cited by
- 92
- References
- 23
- Citations by year
- 2026: 5 · 2025: 5 · 2024: 5 · 2023: 7 · 2022: 21 · 2021: 8 · 2020: 6 · 2019: 14 · 2018: 9 · 2017: 10 · 2016: 2
- FWCI
- 9.39
- Type
- journal article
- Language
- en
- Open access
- Licence
- other-oa
- Locations
- Clinical Chemistry and Laboratory Medicine (CCLM) (publishedVersion)
- PubMed (publishedVersion)
- Pure Amsterdam UMC (publishedVersion)
- Data Archiving and Networked Services (DANS) (submittedVersion)
- University of Southern Denmark Research Portal (University of Southern Denmark) (submittedVersion, other-oa)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Microbiology (medical) › Bacterial Identification and Susceptibility Testing
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Patient Safety and Medication Errors
- Keywords
- pre-analytical phase, phlebotomy, venipuncture, sample contamination, additive interference, patient safety, laboratory errors
- MeSH terms
- Europe, Humans, Phlebotomy, Clinical Chemistry Tests
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.