Compliance of blood sampling procedures with the CLSI H3-A6 guidelines: An observational study by the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) working group for the preanalytical phase (WG-PRE)
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
An observational study was conducted in 12 European countries by the European Federation of Clinical Chemistry and Laboratory Medicine Working Group for the Preanalytical Phase (EFLM WG-PRE) to assess the level of compliance with the CLSI H3-A6 guidelines. A structured checklist including 29 items was created to assess the compliance of European phlebotomy procedures with the CLSI H3-A6 guideline. A risk occurrence chart of individual phlebotomy steps was created from the observed error frequency and severity of harm of each guideline key issue. The severity of errors occurring during phlebotomy was graded using the risk occurrence chart. Twelve European countries participated with a median of 33 (18–36) audits per country, and a total of 336 audits. The median error rate for the total phlebotomy procedure was 26.9 % (10.6–43.8), indicating a low overall compliance with the recommended CLSI guideline. Patient identification and test tube labelling were identified as the key guideline issues with the highest combination of probability and potential risk of harm. Administrative staff did not adhere to patient identification procedures during phlebotomy, whereas physicians did not adhere to test tube labelling policy. The level of compliance of phlebotomy procedures with the CLSI H3-A6 guidelines in 12 European countries was found to be unacceptably low. The most critical steps in need of immediate attention in the investigated countries are patient identification and tube labelling.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
From best evidence to best practice: effective implementation of change in patients' care
Grol, R., & Grimshaw, J. (2003) · The Lancet · doi:10.1016/s0140-6736(03)14546-1 · Cited by 4,531
Successes and Failures in the Implementation of Evidence-Based Guidelines for Clinical Practice
Grol, R. (2001) · Medical Care · doi:10.1097/00005650-200108002-00003 · Cited by 1,233
Planning and Studying Improvement in Patient Care: The Use of Theoretical Perspectives
GROL, R. P. T. M., BOSCH, M. C., HULSCHER, M. E. J. L., ECCLES, M. P., & WENSING, M. (2007) · The Milbank Quarterly · doi:10.1111/j.1468-0009.2007.00478.x · Cited by 943
Standardization of collection requirements for fasting samples
Simundic, A. M., Cornes, M., Grankvist, K., Lippi, G., & Nybo, M. (2014) · Clinica Chimica Acta · doi:10.1016/j.cca.2013.11.008 · Cited by 156
Self-citationFoy, R., Ovretveit, J., Shekelle, P. G., Pronovost, P. J., Taylor, S. L., Dy, S., Hempel, S., McDonald, K. M., Rubenstein, L. V., & Wachter, R. M. (2011) · BMJ Quality & Safety · doi:10.1136/bmjqs.2010.047993 · Cited by 148
Nikolac, N., Šupak Smolčić, V., Šimundić, A.-M., & Ćelap, I. (2013) · Biochemia Medica · doi:10.11613/bm.2013.031 · Cited by 99
Self-citationLima-Oliveira, G., Lippi, G., Salvagno, G. L., Montagnana, M., Picheth, G., & Guidi, G. C. (2012) · Biochemia Medica · doi:10.11613/bm.2012.036 · Cited by 66 · cited 1×
“Changes in laboratory methods can lead to a need to adapt phlebotomy procedures, and training can help to improve practices [19, 20].”
BackgroundSelf-citationThe importance of implementing safe sharps practices in the laboratory setting in Europe
De Carli, G., Abiteboul, D., & Puro, V. (2014) · Biochemia Medica · doi:10.11613/bm.2014.007 · Cited by 61 · cited 1×
“In addition to factors that can affect sample quality, some practices can also have an impact on patient or healthcare worker safety [13].”
BackgroundCould light meal jeopardize laboratory coagulation tests?
Lima-Oliveira, G., Salvagno, G. L., Lippi, G., Danese, E., Gelati, M., Montagnana, M., Picheth, G., & Guidi, G. C. (2014) · Biochemia Medica · doi:10.11613/bm.2014.036 · Cited by 30
Self-citation
Cited by
Joint EFLM-COLABIOCLI Recommendation for venous blood sampling
Simundic, A.-M., Bölenius, K., Cadamuro, J., Church, S., Cornes, M. P., van Dongen-Lases, E. C., Eker, P., Erdeljanovic, T., Grankvist, K., Guimaraes, J. T., et al. (2018) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2018-0602 · Cited by 240
Self-citationLima-Oliveira, G., Volanski, W., Lippi, G., Picheth, G., & Guidi, G. C. (2017) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2017.1295317 · Cited by 117
Self-citationPhlebotomy, a bridge between laboratory and patient
Ialongo, C., & Bernardini, S. (2016) · Biochemia Medica · doi:10.11613/bm.2016.002 · Cited by 97
“Therefore, the phlebotomist should record such events like a poor patient preparation, the failure to rest or fast before blood collection, a body position different from sitting, the presence of a venous line in a neighbouring vascular district, a difficult vascular access, etcetera (127).”
Cornes, M., van Dongen-Lases, E., Grankvist, K., Ibarz, M., Kristensen, G., Lippi, G., Nybo, M., & Simundic, A.-M. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2016-0426 · Cited by 92
Self-citationPatient identification and tube labelling – a call for harmonisation
van Dongen-Lases, E. C., Cornes, M. P., Grankvist, K., Ibarz, M., Kristensen, G. B. B., Lippi, G., Nybo, M., Simundic, A.-M., & on behalf of the Working Group for Preanalytical Phase (WG-P (2016) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2015-1089 · Cited by 69
Self-citation
Metadata
- Authors
- Simundic, A.-M., Church, S., Cornes, M. P., Grankvist, K., Lippi, G., Nybo, M., Nikolac, N., van Dongen-Lases, E., Eker, P., Kovalevskaya, S., Kristensen, G. B. B., Sprongl, L., & Sumarac, Z.
- Venue
- Clinical Chemistry and Laboratory Medicine (CCLM)
- Publisher
- Walter de Gruyter GmbH
- Published
- 2015-01-01
- Volume
- 53
- Issue
- 9
- Pages
- 1321-31
- ISSN
- 1434-6621 (ISSN-L)
- 1437-4331
- OpenAlex
- W2058618991
- Cited by
- 95
- References
- 9
- FWCI
- 6.03
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Compliance of blood sampling procedures with the CLSI H3-A6 guidelines: An observational study by the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) working group for the preanalytical phase (WG-PRE). https://app.cochat.ai/papers/10.1515/cclm-2014-1053
- The paper
- Simundic, A.-M., Church, S., Cornes, M. P., Grankvist, K., Lippi, G., Nybo, M., Nikolac, N., van Dongen-Lases, E., Eker, P., Kovalevskaya, S., Kristensen, G. B. B., Sprongl, L., & Sumarac, Z. (2015). Compliance of blood sampling procedures with the CLSI H3-A6 guidelines: An observational study by the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) working group for the preanalytical phase (WG-PRE). Clinical Chemistry and Laboratory Medicine (CCLM). https://doi.org/10.1515/cclm-2014-1053
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.