CoChat

Provisional standardization of hepcidin assays: creating a traceability chain with a primary reference material, candidate reference method and a commutable secondary reference material

Open access
Diepeveen, Laura E., Laarakkers, Coby M.M., Martos, Gustavo, Pawlak, Marta E., Uğuz, Fatih F., Verberne, Kim E.S.A., van Swelm, Rachel P.L., Klaver, Siem, de Haan, Anton F.J., Pitts, Kelly R., Bansal, Sukhvinder S., Abbas, Ioana M., Fillet, Marianne, Lefebvre, Thibaud, Geurts-Moespot, Anneke J., Girelli, Domenico, Castagna, Annalisa, Herkert, Matthias, Itkonen, Outi, Olbina, Gordana, Tomosugi, Naohisa, Westerman, Mark E., Delatour, Vincent, Weykamp, Cas W., Swinkels, Dorine W. · 2019 · Clinical Chemistry and Laboratory Medicine (CCLM)
Cited by 63

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Background: Hepcidin concentrations measured by various methods differ considerably, complicating interpretation. Here, a previously identified plasma-based candidate secondary reference material (csRM) was modified into a serum-based two-leveled sRM. We validated its functionality to increase the equivalence between methods for international standardization. Methods: We applied technical procedures developed by the International Consortium for Harmonization of Clinical Laboratory Results. The sRM, consisting of lyophilized serum with cryolyoprotectant, appeared commutable among nine different measurement procedures using 16 native human serum samples in a first round robin (RR1). Harmonization potential of the sRM was simulated in RR1 and evaluated in practice in RR2 among 11 measurement procedures using three native human plasma samples. Comprehensive purity analysis of a candidate primary RM (cpRM) was performed by state of the art procedures. The sRM was value assigned with an isotope dilution mass spectrometry-based candidate reference method calibrated using the certified pRM. Results: The inter-assay CV without harmonization was 42.1% and 52.8% in RR1 and RR2, respectively. In RR1, simulation of harmonization with sRM resulted in an inter-assay CV of 11.0%, whereas in RR2 calibration with the material resulted in an inter-assay CV of 19.1%. Both the sRM and pRM passed international homogeneity criteria and showed long-term stability. We assigned values to the low (0.95±0.11 nmol/L) and middle concentration (3.75±0.17 nmol/L) calibrators of the sRM. Conclusions: Standardization of hepcidin is possible with our sRM, which value is assigned by a pRM. We propose the implementation of this material as an international calibrator for hepcidin.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1515/cclm-2018-0783

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Diepeveen, L. E., Laarakkers, C. M. M., Martos, G., Pawlak, M. E., Uğuz, F. F., Verberne, K. E. S. A., van Swelm, R. P. L., Klaver, S., de Haan, A. F. J., Pitts, K. R., Bansal, S. S., Abbas, I. M., Fillet, M., Lefebvre, T., Geurts-Moespot, A. J., Girelli, D., Castagna, A., Herkert, M., Itkonen, O., Olbina, G., Tomosugi, N., Westerman, M. E., Delatour, V., Weykamp, C. W., & Swinkels, D. W.
Venue
Clinical Chemistry and Laboratory Medicine (CCLM)
Published
2018-11-29
Volume
57
Issue
6
Pages
864-872
ISSN
  • 1434-6621 (ISSN-L)
  • 1437-4331
OpenAlex
W2902581126
Cited by
63
References
3
FWCI
3.86
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.