The DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
The role of ethylenediamine tetraacetic acid (EDTA) as in vitro anticoagulant for diagnostic purposes
Abstract
Anticoagulants are used to prevent clot formation both in vitro and in vivo. In the specific field of in vitro diagnostics, anticoagulants are commonly added to collection tubes either to maintain blood in the fluid state for hematological testing or to obtain suitable plasma for coagulation and clinical chemistry analyses. Unfortunately, no universal anticoagulant that could be used for evaluation of several laboratory parameters in a sample from a single test tube is available so far. Ethylenediamine tetraacetic acid (EDTA) is a polyprotic acid containing four carboxylic acid groups and two amine groups with lone-pair electrons that chelate calcium and several other metal ions. Calcium is necessary for a wide range of enzyme reactions of the coagulation cascade and its removal irreversibly prevents blood clotting within the collection tube. Historically, EDTA has been recommended as the anticoagulant of choice for hematological testing because it allows the best preservation of cellular components and morphology of blood cells. The remarkable expansion in laboratory test volume and complexity over recent decades has amplified the potential spectrum of applications for this anticoagulant, which can be used to stabilize blood for a variety of traditional and innovative tests. Specific data on the behavior of EDTA as an anticoagulant in hematology, including possible pitfalls, are presented. The use of EDTA for measuring cytokines, protein and peptides, and cardiac markers is described, with an outline of the protection of labile molecules provided by this anticoagulant. The use of EDTA in proteomics and in general clinical chemistry is also described in comparison with other anticoagulants and with serum samples. Finally, the possible uses of alternative anticoagulants instead of EDTA and the potential use of a universal anticoagulant are illustrated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
National Committee for Clinical Laboratory Standards
Bruck, E. (1980) · Pediatrics · doi:10.1542/peds.65.1.187 · Cited by 14,751
Nielsen, F., Mikkelsen, B. B., Nielsen, J. B., Andersen, H. R., & Grandjean, P. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.7.1209 · Cited by 1,016
Lipid Research Clinics Program
Renfrew, R. A. (1984) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1984.03350180015009 · Cited by 829
Stability of Endogenous and Added RNA in Blood Specimens, Serum, and Plasma
Tsui, N. B., Ng, E. K., & Lo, Y. D. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.10.1647 · Cited by 627
Design and characterization of hirulogs: a novel class of bivalent peptide inhibitors of thrombin
Maraganore, J. M., Bourdon, P., Jablonski, J., Ramachandran, K. L., & Fenton, J. W. (1990) · Biochemistry · doi:10.1021/bi00482a021 · Cited by 466
Lee, T., Montalvo, L., Chrebtow, V., & Busch, M. P. (2001) · Transfusion · doi:10.1046/j.1537-2995.2001.41020276.x · Cited by 311
Multicenter evaluation of the Roche NT-proBNP assay and comparison to the Biosite Triage BNP assay
Yeo, K.-T. J., Wu, A. H. B., Apple, F. S., Kroll, M. H., Christenson, R. H., Lewandrowski, K. B., Sedor, F. A., & Butch, A. W. (2003) · Clinica Chimica Acta · doi:10.1016/j.cccn.2003.08.016 · Cited by 296
Banks, R. E., Stanley, A. J., Cairns, D. A., Barrett, J. H., Clarke, P., Thompson, D., & Selby, P. J. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2005.051417 · Cited by 240
Effect of anticoagulants and storage temperatures on stability of plasma and serum hormones
Evans, M. J., Livesey, J. H., Ellis, M. J., & Yandle, T. G. (2001) · Clinical Biochemistry · doi:10.1016/s0009-9120(01)00196-5 · Cited by 223
Critical issues in cyclosporine monitoring: report of the Task Force on Cyclosporine Monitoring.
(1987) · Clinical Chemistry · doi:10.1093/clinchem/33.7.1269 · Cited by 219
Plasma renin activity and plasma prorenin assays
Sealey, J. E. (1991) · Clinical Chemistry · doi:10.1093/clinchem/37.10.1811 · Cited by 207
Clerico, A., Iervasi, G., Del Chicca, M. G., Emdin, M., Maffei, S., Nannipieri, M., Sabatino, L., Forini, F., Manfredi, C., & Donato, L. (1998) · Journal of Endocrinological Investigation · doi:10.1007/bf03347297 · Cited by 188
EFFECTS OF SAMPLE HANDLING ON THE STABILITY OF INTERLEUKIN 6, TUMOUR NECROSIS FACTOR-α AND LEPTIN
Flower, L., Ahuja, R. H., Humphries, S. E., & Mohamed-Ali, V. (2000) · Cytokine · doi:10.1006/cyto.2000.0764 · Cited by 178
Riches, P. G., Gooding, R. P., Millar, B. C., & Rowbottom, A. W. (1992) · Journal of Immunological Methods · doi:10.1016/0022-1759(92)90314-j · Cited by 141
Rai, A. J., & Vitzthum, F. (2006) · Expert Review of Proteomics · doi:10.1586/14789450.3.4.409 · Cited by 138
England, J. M., Rowan, R. M., van Assendelft, O. W., Bull, B. S., Coulter, W. H., Fujimoto, K., Groner, W., Richardson-Jones, A., Klee, G. G., Koepke, J. A., et al. (1993) · American Journal of Clinical Pathology · doi:10.1093/ajcp/100.4.371 · Cited by 132
Brugnara, C., Colella, G. M., Cremins, J. E., Langley, R. C., Schneider, T. J., Rutherford, C., & Goldberg, M. A. (1994) · PubMed · Cited by 124
Analytical and Preanalytical Biases in Serum Proteomic Pattern Analysis for Breast Cancer Diagnosis
Karsan, A., Eigl, B. J., Flibotte, S., Gelmon, K. A., Switzer, P., Hassell, P., Harrison, D., Law, J. H., Hayes, M. M., Stillwell, M., et al. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2005.050708 · Cited by 116
Gerhardt, W., Nordin, G., Herbert, A.-K., Burzell, B. L., Isaksson, A., Gustavsson, E., Haglund, S., Müller-Bardorff, M., & Katus, H. A. (2000) · Clinical Chemistry · doi:10.1093/clinchem/46.6.817 · Cited by 108
Modulation of Blood Cell Activation by Four Commonly Used Anticoagulants
Engstad, C. S., Gutteberg, T. J., & Østerud, B. (1997) · Thrombosis and Haemostasis · doi:10.1055/s-0038-1656035 · Cited by 102
Pandian, M. R., MORGAN, C. H., Carlton, E. I., & Segre, G. V. (1992) · Clinical Chemistry · doi:10.1093/clinchem/38.2.282 · Cited by 101
Proteomics: The next revolution in laboratory medicine?
Plebani, M. (2005) · Clinica Chimica Acta · doi:10.1016/j.cccn.2005.03.017 · Cited by 83
Buckley, M. G., MARCUS, N. J., & Yacoub, M. H. (1999) · Clinical Science · doi:10.1042/cs0970689 · Cited by 83
Bartels, P. C. M., Schoorl, M. G., & Lombarts, A. J. P. F. (1997) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365519709055287 · Cited by 83
Multicenter analytical performance evaluation of the Elecsys® proBNP assay
Sokoll, L. J., Baum, H. H. E., Collinson, P. O., Gurr, E., Haass, M., Luthe, H., Morton, J. J., Nowatzke, W. L., & Zingler, C. (2004) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2004.157 · Cited by 73
Preanalytical phase of sport biochemistry and haematology.
Banfi, G., & Dolci, A. (2003) · PubMed · Cited by 67
Self-citationLippi, G., Salvagno, G. L., Solero, G. P., Franchini, M., & Guidi, G. C. (2005) · Journal of Laboratory and Clinical Medicine · doi:10.1016/j.lab.2005.08.004 · Cited by 66
Self-citationUlmert, D., Becker, C., Nilsson, J., Piironen, T., Björk, T., Hugosson, J., Berglund, G. L., & Lilja, H. G. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2005.050641 · Cited by 66
Acidic Citrate Stabilizes Blood Samples for Assay of Total Homocysteine
Willems, H. P. J., Bos, G. M. J., Gerrits, W. B. J., den Heijer, M., Vloet, S., & Blom, H. J. (1998) · Clinical Chemistry · doi:10.1093/clinchem/44.2.342 · Cited by 62
Bernkop‐Schnürch, A., & Scerbe-Saiko, A. (1998) · Pharmaceutical Research · doi:10.1023/a:1011970703087 · Cited by 55
Standards of laboratory practice: cardiac drug monitoring
Valdes, R., Jortani, S. A., & Gheorghiade, M. (1998) · Clinical Chemistry · doi:10.1093/clinchem/44.5.1096 · Cited by 55
Grant, P. R., Kitchen, A. D., Barbara, J. A. J., Hewitt, P. E., Sims, C. M., Garson, J. A., & Tedder, R. S. (2000) · Vox Sanguinis · doi:10.1046/j.1423-0410.2000.7830137.x · Cited by 54
Pre‐analytical factors and measurement uncertainty
Kouri, T., Siloaho, M., Pohjavaara, S., et al. (2005) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365510500208332 · Cited by 50
The stability of blood, plasma and serum constituents during simulated transport
Felding, P., Petersen, P. H., & Hørder, M. (1981) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365518109092012 · Cited by 49
Optimal collection of blood samples for the measurement of tumor necrosis factor ?
Exley, A. (1990) · Cytokine · doi:10.1016/1043-4666(90)90065-2 · Cited by 37
Preanalytical factors and the measurement of cytokines in human subjects
Dugué, B., Leppänen, E., & Gräsbeck, R. (1996) · International Journal of Clinical & Laboratory Research · doi:10.1007/bf02592351 · Cited by 35
In vitro stability of osteocalcin.
Banfi, G., & Daverio, R. (1994) · Clinical Chemistry · doi:10.1093/clinchem/40.5.833a · Cited by 33
Self-citationEffects of contamination of blood specimens with liquid potassium-EDTA anticoagulant
Davidson, D. F. (2002) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/0004563021901973 · Cited by 31
Chuang, C., Lin, S., Lin, Y., & Huang, C. (1998) · Clinical Chemistry · doi:10.1093/clinchem/44.5.1052 · Cited by 30
Stability of Blood Homocysteine and Other Thiols: EDTA or Acidic Citrate?
Salazar, J.-F., Herbeth, B., Siest, G., & Leroy, P. (1999) · Clinical Chemistry · doi:10.1093/clinchem/45.11.2016 · Cited by 28
Hoffmann, J. N., Hartl, W. H., Faist, E., Jochum, M., & Inthorn, D. (1997) · Inflammation Research · doi:10.1007/s000110050199 · Cited by 23
The Q-Prep system: Effects on the apparent expression of leucocyte cell surface antigens
Macey, M. G., McCarthy, D. A., Davies, C., & Newland, A. C. (1997) · Cytometry · Cited by 22
Use of EDTA samples for prothrombin time measurement in patients receiving oral anticoagulants.
Horsti, J. E. (2001) · PubMed · Cited by 10
Bladbjerg, E., Overgaard, K., Gram, J., & Jespersen, J. (1995) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365519509089623 · Cited by 6
Cited by
Superhydrophobic hemostatic nanofiber composites for fast clotting and minimal adhesion
Li, Z., Milionis, A., Zheng, Y., Yee, M., Codispoti, L., Tan, F., Poulikakos, D., & Yap, C. H. (2019) · Nature Communications · doi:10.1038/s41467-019-13512-8 · Cited by 329
Lippi, G., von Meyer, A., Cadamuro, J., & Simundic, A.-M. (2019) · Diagnosis · doi:10.1515/dx-2018-0018 · Cited by 135
Self-citationLima-Oliveira, G., Volanski, W., Lippi, G., Picheth, G., & Guidi, G. C. (2017) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2017.1295317 · Cited by 117
Self-citationPullar, J., Bayer, S., & Carr, A. (2018) · Antioxidants · doi:10.3390/antiox7020029 · Cited by 92
Metadata
- Authors
- Banfi, G., Salvagno, G. L., & Lippi, G.
- Venue
- Clinical Chemical Laboratory Medicine
- Publisher
- Walter de Gruyter GmbH
- Published
- 2007-01-01
- Volume
- 45
- Issue
- 5
- Pages
- 565-76
- ISSN
- 1434-6621 (ISSN-L)
- 1437-4331
- OpenAlex
- W2049397086
- Cited by
- 297
- References
- 45
- FWCI
- 2.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.