Preanalytical errors in primary healthcare: a questionnaire study of information search procedures, test request management and test tube labelling
The DOI matches its Crossref record.
Abstract
: Most errors in laboratory medicine occur in the preanalytical phase and are the result of human mistakes. This study investigated information search procedures, test request management and test tube labelling in primary healthcare compared to the same procedures amongst clinical laboratory staff. : A questionnaire was completed by 317 venous blood sampling staff in 70 primary healthcare centres and in two clinical laboratories (response rate = 94%). : Correct procedures were not always followed. Only 60% of the primary healthcare staff reported that they always sought information in the updated, online laboratory manual. Only 12% reported that they always labelled the test tubes prior to drawing blood samples. No major differences between primary healthcare centres and clinical laboratories were found, except for test tube labelling, whereby the laboratory staff reported better practices. Re-education and access to documented routines were not clearly associated with better practices. : The preanalytical procedure in the surveyed primary healthcare centres was associated with a risk of errors which could affect patient safety. To improve patient safety in laboratory testing, all healthcare providers should survey their preanalytical procedures and improve the total testing process with a systems perspective. Clin Chem Lab Med 2009;47:195–201.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Preanalytical quality improvement: from dream to reality
Lippi, G., Chance, J. J., Church, S., Dazzi, P., Fontana, R., Giavarina, D., Grankvist, K., Huisman, W., Kouri, T., Palicka, V., et al. (2011) · Clinical Chemistry and Laboratory Medicine · doi:10.1515/cclm.2011.600 · Cited by 388
Self-citationLima-Oliveira, G., Volanski, W., Lippi, G., Picheth, G., & Guidi, G. C. (2017) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2017.1295317 · Cited by 117
Simundic, A.-M., Cornes, M., Grankvist, K., Lippi, G., Nybo, M., Kovalevskaya, S., Sprongl, L., Sumarac, Z., & Church, S. (2013) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2013-0283 · Cited by 84
Self-citationBölenius, K., Lindkvist, M., Brulin, C., Grankvist, K., Nilsson, K., & Söderberg, J. (2013) · BMC Health Services Research · doi:10.1186/1472-6963-13-463 · Cited by 30
“Common specimen handling errors include incorrect test tube labelling [2,15,20,21], incorrect test request management, missing tubes, and transport errors [2,8,10,14,22].”
BackgroundMethodInfluentialSelf-citation
Metadata
- Authors
- Söderberg, J., Brulin, C., Grankvist, K., & Wallin, O.
- Venue
- Clinical Chemistry and Laboratory Medicine
- Publisher
- Walter de Gruyter GmbH
- Published
- 2009-01-01
- Volume
- 47
- Issue
- 2
- Pages
- 195-201
- ISSN
- 1434-6621 (ISSN-L)
- 1437-4331
- OpenAlex
- W1986029575
- Cited by
- 64
- References
- 0
- FWCI
- 2.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Preanalytical errors in primary healthcare: a questionnaire study of information search procedures, test request management and test tube labelling. https://app.cochat.ai/papers/10.1515/cclm.2009.048
- The paper
- Söderberg, J., Brulin, C., Grankvist, K., & Wallin, O. (2009). Preanalytical errors in primary healthcare: a questionnaire study of information search procedures, test request management and test tube labelling. Clinical Chemistry and Laboratory Medicine. https://doi.org/10.1515/cclm.2009.048
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.