Cited by 15Stroke Rehabilitation and RecoveryContext-Aware Activity Recognition SystemsProsthetics and Rehabilitation Robotics

Wearable motion sensors and digital biomarkers in stroke rehabilitation

Open access
Derungs, Adrian, Schuster-Amft, Corina, Amft, Oliver·2020·Current Directions in Biomedical Engineering

Abstract

Abstract We propose three novel digital biomarkers for the longitudinal performance monitoring and movement evaluation of hemiparetic patients, e.g. after stroke. We devised convergence points (CP) for the bilateral walking analysis based on gait parameters, e.g. stride duration using regression- modelling to estimate similarity between body sides. The physical activity (PA) was devised to evaluate the energy expenditure of all extremities during training and free-living. The functional range of motion (fROM) is a digital biomarker to quantify the upper arm reaching ability, represented in 3D visualisations. In this work, we detail CP, PA, and fROM to derive rehabilitation insights for personalising therapies. We evaluated the proposed digital biomarkers in a clinical observation study with 11 patients after stroke during their rehabilitation including therapy and self-paced daily routines.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1515/cdbme-2020-3058

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Other included studies monitored participants in an outpatient home environment.

    “Other studies monitored participants in an outpatient home environment [63].”

    From Wearable sensors and machine learning in post-stroke rehabilitation assessment: A systematic review (2022) · cites this paper as [63]

    Sections 4.1 and 4.2 describe monitoring outpatients during therapy and freely chosen daily routines at a rehabilitation day-care centre. They do not establish that monitoring took place in participants’ homes; Section 6 describes monitoring after discharge as a future application. (LLM, conf=0.88)

    Experimental — accuracy not yet measured
  • Derungs extracted digital biomarkers consisting of convergence points, physical activity, and functional range of motion to investigate the affected and less-affected body side.

    “In [63] Derungs extracted digital biomarkers consisting of convergence points physical activity and functional ROM to investigate the affected and less-affected body side.”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 1

  1. Derungs, A., Seiter, S., Schuster-Amft, C., Amft, O., Es- timating physical ability of stroke patients without speci- fic tests, Proceedings of the 2015 ACM International Symposium on Wearable Computers (ISWC '15).

Cited by

Sorted by citations

Authors
Derungs, A., Schuster-Amft, C., & Amft, O.
Affiliations
  • Friedrich-Alexander-Universität Erlangen-Nürnberg (DE)
  • Research Department, Reha Rheinfelden, Rheinfelden , Switzerland
Venue
Current Directions in Biomedical Engineering
Published
2020-09-01
Volume
6
Issue
3
Pages
229-232
ISSN
2364-5504 (ISSN-L)
OpenAlex
W3132717321
Cited by
15
References
9
Citations by year
2026: 2 · 2025: 1 · 2024: 1 · 2023: 5 · 2022: 3 · 2021: 3
FWCI
1.53
Type
journal article
Language
en
Open access
Locations
  • Current Directions in Biomedical Engineering (publishedVersion, cc-by)
  • OPUS FAU (Kooperativer Bibliotheksverbund Berlin-Brandenburg (KOBV), on behalf of the Universitätsbibliothek Erlangen-Nürnberg) (submittedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
  • Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
Keywords
digital biomarkers, stroke rehabilitation, wearable motion sensors, hemiparesis, convergence point, gait analysis, physical activity, energy expenditure, functional range of motion, personalized treatment

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review