The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Sample Size for Assessing Agreement between Two Methods of Measurement by Bland−Altman Method
Open accessAbstract
The Bland–Altman method has been widely used for assessing agreement between two methods of measurement. However, it remains unsolved about sample size estimation. We propose a new method of sample size estimation for Bland–Altman agreement assessment. According to the Bland–Altman method, the conclusion on agreement is made based on the width of the confidence interval for LOAs (limits of agreement) in comparison to predefined clinical agreement limit. Under the theory of statistical inference, the formulae of sample size estimation are derived, which depended on the pre-determined level of α , β, the mean and the standard deviation of differences between two measurements, and the predefined limits. With this new method, the sample sizes are calculated under different parameter settings which occur frequently in method comparison studies, and Monte-Carlo simulation is used to obtain the corresponding powers. The results of Monte-Carlo simulation showed that the achieved powers could coincide with the pre-determined level of powers, thus validating the correctness of the method. The method of sample size estimation can be applied in the Bland–Altman method to assess agreement between two methods of measurement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
Research guidelines for the Delphi survey technique
Hasson, F. (2000) · Journal of Advanced Nursing · doi:10.1046/j.1365-2648.2000.01567.x · Cited by 5,951
Applying the right statistics: analyses of measurement studies
Bland, J. M., & Altman, D. G. (2003) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.122 · Cited by 1,311
Sample sizes for clinical trials with normal data.
Julious, S. A. (2004) · Statistics in Medicine · doi:10.1002/sim.1783 · Cited by 605
Statistical Intervals: A Guide for Practitioners
Hahn, G. J., & Meeker, W. Q. (1991) · Wiley Series in Probability and Statistics · doi:10.1002/9780470316771 · Cited by 566
Statistical Intervals: A Guide For Practitioners
Jones, J. R. (1993) · Technometrics · doi:10.1080/00401706.1993.10485329 · Cited by 537
Van Noorden, R., Maher, B., & Nuzzo, R. (2014) · Nature · doi:10.1038/514550a · Cited by 508
Forbes, C., Evans, M., Hastings, N., & Peacock, B. (2010) · Wiley eBooks · doi:10.1002/9780470627242 · Cited by 453
McAlinden, C., Khadka, J., & Pesudovs, K. (2011) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2011.00851.x · Cited by 436
Confidence in Altman–Bland plots: A critical review of the method of differences
Ludbrook, J. (2010) · Clinical and Experimental Pharmacology and Physiology · doi:10.1111/j.1440-1681.2009.05288.x · Cited by 366
Agreed Statistics: Measurement Method Comparison
Bland, J. M., Altman, D. G., & Warner, D. S. (2012) · Anesthesiology · doi:10.1097/aln.0b013e31823d7784 · Cited by 252
Chhapola, V., Kanwal, S. K., & Brar, R. (2014) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/0004563214553438 · Cited by 82
Stöckl, D., Rodríguez Cabaleiro, D., Van Uytfanghe, K., & Thienpont, L. M. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.036095 · Cited by 79
Hamilton, C., & Stamey, J. D. (2007) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-007-9092-x · Cited by 72
Bell, M. L., Teixeira-Pinto, A. M., McKenzie, J. E., & Olivier, J. (2014) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2013.10.008 · Cited by 30
Bland–Altman beyond the basics: Creating confidence with badly behaved data
Woodman, R. J. (2009) · Clinical and Experimental Pharmacology and Physiology · doi:10.1111/j.1440-1681.2009.05320.x · Cited by 15
Lin, S. C., Whipple, D. M., & Ho, C. S. (1998) · Communication in Statistics- Theory and Methods · doi:10.1080/03610929808832167 · Cited by 14
Allowable Total Error and Limits for Erroneous Results (ATE/LER) zones for agreement measurement
Zhou, Y., Zang, J., Wu, M., Xu, J., & He, J. (2011) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.20437 · Cited by 8
Agreement analysis: further statistical insights
Cesana, B. M., & Antonelli, P. (2012) · Ophthalmic and Physiological Optics · doi:10.1111/j.1475-1313.2012.00916.x · Cited by 7
Cited by
Serdar, C. C., Cihan, M., Yücel, D., & Serdar, M. A. (2021) · Biochemia medica · doi:10.11613/bm.2021.010502 · Cited by 1,570
Reporting Standards for a Bland–Altman Agreement Analysis: A Review of Methodological Reviews
Gerke, O. (2020) · Diagnostics · doi:10.3390/diagnostics10050334 · Cited by 246
Multiplex Assays in Allergy Diagnosis: Allergy Explorer 2 versus ImmunoCAP ISAC E112i
Nösslinger, H., Mair, E., Oostingh, G. J., Ahlgrimm-Siess, V., Ringauf, A., & Lang, R. (2024) · Diagnostics · doi:10.3390/diagnostics14100976 · Cited by 21
Metadata
- Authors
- Lu, M.-J., Zhong, W.-H., Liu, Y.-X., Miao, H.-Z., Li, Y.-C., & Ji, M.-H.
- Venue
- The International Journal of Biostatistics
- Publisher
- Walter de Gruyter GmbH
- Published
- 2016-11-01
- Volume
- 12
- Issue
- 2
- ISSN
- 1557-4679 (ISSN-L)
- 2194-573X
- OpenAlex
- W2556912902
- Cited by
- 306
- References
- 21
- FWCI
- 12.83
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.