BioVar: an online biological variation analysis tool.
Open accessThe DOI matches its Crossref record; 26 of the 27 references it cites were found in a registry or an index.
Abstract
Abstract Objectives Biological variation (BV) analysis of laboratory tests gets increased attention due to its practical applications. These applications include correct interpretation of laboratory tests, the decision on the availability of reference intervals, contributions to clinical decision-making. It is critical to derive the BV information accurately and reliably. Another crucial step is to perform the statistical analysis of the BV data. Although there are updated and comprehensive guidelines, there is no reliable and comprehensive tool to perform statistical analysis of BV data. Methods We presented BioVar, an online tool for statistical analysis of the BV data based on available and updated guidelines. Results This tool can be used (i) to detect outliers, (ii) to control normality assumption, (iii) to check steady-state condition, (iv) to test homogeneity assumptions, (v) to perform subset analysis for genders, (vi) to perform analysis of variance to estimate components of variation and (vii) to identify analytical performance specifications of laboratory tests. Moreover, plots can be created at each step of outlier detection to inspect outliers and compare gender groups visually. An automatic report can be generated and downloaded. Conclusion The tool is freely available through turcosa.shinyapps.io/biovar/ , and source code is available on the Github: github.com/selcukorkmaz/BioVar .
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Generation and Application of Data on Biological Variation in Clinical Chemistry
Fraser, G. G., & Harris, E. K. (1989) · Critical Reviews in Clinical Laboratory Sciences · doi:10.3109/10408368909106595 · Cited by 870
Sandberg, S., Fraser, C. G., Horvath, A. R., Jansen, R., Jones, G., Oosterhuis, W., Petersen, P. H., Schimmel, H., Sikaris, K., & Panteghini, M. (2015) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2015-0067 · Cited by 563
Proposals for Setting Generally Applicable Quality Goals Solely Based on Biology
Fraser, C. G., Petersen, P. H., Libeer, J.-C., & Ricos, C. (1997) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1177/000456329703400103 · Cited by 370
Fraser, C. G. (2012) · Clinical Chemistry and Laboratory Medicine · doi:10.1515/cclm.2011.733 · Cited by 286
Aarsand, A. K., Røraas, T., Fernandez-Calle, P., Ricos, C., Díaz-Garzón, J., Jonker, N., Perich, C., González-Lao, E., Carobene, A., Minchinela, J., et al. (2018) · Clinical Chemistry · doi:10.1373/clinchem.2017.281808 · Cited by 233
Inherent biological variation and reference values
Fraser, C. G. (2004) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2004.128 · Cited by 222
Burdick, R. K., Borror, C. M., & Montgomery, D. C. (2005) · Society for Industrial and Applied Mathematics eBooks · doi:10.1137/1.9780898718379 · Cited by 198 · cited 1×
“The estimation of variance components using a nested ANOVA does not assume a normal distribution or any other distributions for the model effects [6, 14, 15].”
MethodReference Change Values for Brain Natriuretic Peptides Revisited
Fokkema, M. R., Herrmann, Z., Muskiet, F. A., & Moecks, J. (2006) · Clinical Chemistry · doi:10.1373/clinchem.2006.069369 · Cited by 176
A checklist for critical appraisal of studies of biological variation
Bartlett, W. A., Braga, F., Carobene, A., Coşkun, A., Prusa, R., Fernandez-Calle, P., Røraas, T., Jonker, N., Sandberg, S., & Variati, O. B. O. T. B. (2015) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2014-1127 · Cited by 151
Røraas, T., Støve, B., Petersen, P. H., & Sandberg, S. (2016) · Clinical Chemistry · doi:10.1373/clinchem.2015.252296 · Cited by 128
Generation of data on within-subject biological variation in laboratory medicine: An update
Braga, F., & Panteghini, M. (2016) · Critical Reviews in Clinical Laboratory Sciences · doi:10.3109/10408363.2016.1150252 · Cited by 111
The use of error and uncertainty methods in the medical laboratory
Oosterhuis, W. P., Bayat, H., Armbruster, D., Coşkun, A., Freeman, K. P., Kallner, A., Koch, D. D., MacKenzie, F., Migliarino, G. A., Orth, M., et al. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2017-0341 · Cited by 109
Aarsand, A. K., Díaz-Garzón, J., Fernandez-Calle, P., Guerra, E., Locatelli, M., Bartlett, W. A., Sandberg, S., Røraas, T., Ceriotti, F., Sølvik, U. Ø., et al. (2018) · Clinical Chemistry · doi:10.1373/clinchem.2018.288415 · Cited by 105
Castilla, J. A., Álvarez‐Nieto, C., de Aguilar, J. V. S., González-Varea, C., Gonzalvo, M. C., & Martínez, L. (2005) · Human Reproduction · doi:10.1093/humrep/dei423 · Cited by 94
Statistical aspects of reference values in clinical pathology.
Harris, E. K. (1981) · PubMed · Cited by 69
Sahai, H., & Ojeda, M. M. (2004) · Birkhäuser Boston eBooks · doi:10.1007/978-0-8176-8168-5 · Cited by 69
Gross Overestimation of Total Allowable Error Based on Biological Variation
Oosterhuis, W. P. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2011.165308 · Cited by 66
Biological Variation Estimates Obtained from 91 Healthy Study Participants for 9 Enzymes in Serum
Carobene, A., Røraas, T., Sølvik, U. Ø., Sylte, M. S., Sandberg, S., Guerra, E., Marino, I., Jonker, N., Barla, G., Bartlett, W. A., et al. (2017) · Clinical Chemistry · doi:10.1373/clinchem.2016.269811 · Cited by 63
Coşkun, A., Carobene, A., Kilercik, M., Serteser, M., Sandberg, S., Aarsand, A. K., Fernandez-Calle, P., Jonker, N., Bartlett, W. A., Díaz-Garzón, J., et al. (2018) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2017-1155 · Cited by 62
Petersen, P. H., & Fraser, C. G. (2010) · Accreditation and Quality Assurance · doi:10.1007/s00769-009-0630-8 · Cited by 44
Biological variation – reliable data is essential
Aarsand, A. K., Røraas, T., & Sandberg, S. (2015) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2014-1141 · Cited by 36
Evaluation of Imprecision, Bias and Total Error of Clinical Chemistry Analysers
Biswas, S. S., Bindra, M., Jain, V., & Gokhale, P. (2014) · Indian Journal of Clinical Biochemistry · doi:10.1007/s12291-014-0448-y · Cited by 22
Using Multiples of the Median to Normalize Serum Protein Measurements
PALOMAKI, G. E., & Neveux, L. M. (2001) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2001.180 · Cited by 16
Kristoffersen, A., Petersen, P. H., & Sandberg, S. (2012) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/acb.2012.011265 · Cited by 16
Braga, F., Ferraro, S., Ieva, F., Paganoni, A., & Panteghini, M. (2015) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2014-0893 · Cited by 10
Franzini, C. (1995) · PubMed · Cited by 8
Research works printed but not linked: 4
- Fraser, C. Biological Variation: from Principles to Practice. Washington (DC): AACC Press; 2001.
- Kokoska, S, Christopher, N. Statistical tables and formulae. New York, NY: Springer; 198.
- Razali, NM, Wah, YB. Power comparisons of shapiro-wilk, kolmogorov-smirnov, lilliefors and anderson-darling tests. J Stat Model Anal 2011;2:21–33.
- Snedecor, GW, Cochran, WG. Statistical methods, 8th ed. Ames: Iowa State Univ. Press Iowa; 1989.
Cited by
Diurnal and day-to-day biological variation of salivary cortisol and cortisone
Danese, E., Padoan, A., Negrini, D., Paviati, E., Pastena, M. D., Esposito, A., Lippi, G., & Montagnana, M. (2024) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2024-0196 · Cited by 7
“The BioVar online tool was used to test outliers, normality assumption, steady state and between-gender BV di ff erences [18].”
Çalık, G. Y., & Şeneş, M. (2023) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2022-1290 · Cited by 4
Özkanay, H., Arslan, F. D., Köseoğlu, M., & Yıldız, R. (2025) · Biochemia medica · doi:10.11613/bm.2025.010706 · Cited by 2
Biological variation of serum cholinesterase activity in healthy subjects
Akbulut, E. D., & Ercan, M. (2025) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2025-0240 · Cited by 2
“Statistical analyses were performed using the following platforms: Microsoft Excel (Microsoft ® Excel for Mac, version 10), SPSS 20 and an online BV analysis tool [22] (BioVar, available through https://turcosa.shinyapps.io/ biovar/).”
Biological variation of serum neopterin concentrations in apparently healthy individuals
Dülgeroğlu, Y., & Ercan, M. (2023) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2023-1030 · Cited by 1
Metadata
- Authors
- Korkmaz, S., Zarasız, G., Göksülük, D., Senes, M., Sönmez, C., & Yucel, D.
- Affiliations
- Trakya University (TR)
- Erciyes University (TR)
- Hacettepe University (TR)
- Ministry of Health, University of Health Sciences, Ankara Training and Research Hospital, Medical Biochemistry , Ankara , 06610, Turkey
- Turcosa Analytics Solutions Ltd Co, Erciyes Teknopark 5 , Kayseri , Turkey
- Ankara Training and Research Hospital, Medical Biochemistry, Ulucanlar Caddesi , Ankara , 06340, Turkey
- Corresponding author
- Korkmaz, Selçuk
- Venue
- Turkish Journal of Biochemistry
- Publisher
- Walter de Gruyter GmbH
- Published
- 2020-07-27
- Volume
- 45
- Issue
- 5
- Pages
- 479-489
- ISSN
- 0250-4685 (ISSN-L)
- 1303-829X
- OpenAlex
- W3046072581
- Cited by
- 12
- References
- 27
- Citations by year
- 2026: 2 · 2025: 6 · 2024: 2 · 2023: 2
- FWCI
- 0.30
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- Turkish Journal of Biochemistry (publishedVersion, cc-by)
- Trakya University's Institutional Open Access System (Trakya University) (submittedVersion)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Keywords
- biological variation, biovars, reference values, outlier detection, normality assumption, steady-state conditions, homoscedasticity, gender differences, analysis of variance, analytical performance specifications, laboratory test interpretation, Shiny app
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.