Performance evaluation of internal quality control rules, EWMA, CUSUM, and the novel machine learning model
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
Objectives: The present study set out to build a machine learning model to incorporate conventional quality control (QC) rules, exponentially weighted moving average (EWMA), and cumulative sum (CUSUM) with random forest (RF) algorithm to achieve better performance and to evaluate the performances the models using computer simulation to aid laboratory professionals in QC procedure planning. Methods: Conventional QC rules, EWMA, CUSUM, and RF models were implemented on the simulation data using an in-house algorithm. The models’ performances were evaluated on 170,000 simulated QC results using outcome metrics, including the probability of error detection (Ped), probability of false rejection (Pfr), average run length (ARL), and power graph. Results: The highest Pfr (0.0404) belonged to the 1–2s rule. The 1–3s rule could not detect errors with a 0.9 Ped up to 4 SD of systematic error. The random forest model had the highest Ped for systematic errors lower than 1 SD. However, ARLs of the model require the combined utility of the RF model with conventional QC rules having lower ARLs or more than one QC measurement is required. Conclusions: The RF model presented in this study showed acceptable Ped for most degrees of systematic error. The outcome metrics established in this study will help laboratory professionals planning internal QC.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The study identified CUSUM and EWMA as the most important features in terms of predictive capability.”
From Machine learning-based clinical decision support using laboratory data (2024) · cites this paper as [40]
In the citing paper
“The RF model achieved a low false rejection probability of 0.0048 and demonstrated the highest error detection rate for errors less than one standard deviation.”
From Machine learning-based clinical decision support using laboratory data (2024) · cites this paper as [40]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Breiman, L. (2001) · Machine Learning · doi:10.1023/a:1010933404324 · Cited by 133,538 · cited 1×
“Therandomforestclassi fi ermodelused200decisiontrees,entropyfor information gain, and other default parameters based on the scikit-learn 0.24.1 package [15, 16] (the source code can be downloaded from: https://github.com/hikmetc/IQCAI).”
BackgroundInfluentialScikit-learn: Machine Learning in Python
Pedregosa, F., Varoquaux, G., Gramfort, A., Michel, V., Thirion, B., Grisel, O., Blondel, M., Müller, A., Nothman, J., Louppe, G., et al. (2012) · arXiv · doi:10.48550/arxiv.1201.0490 · Cited by 71,016 · cited 1×
“1 package [15, 16] (the source code can be downloaded”
BackgroundHarris, C. R., Millman, K. J., van der Walt, S. J., Gommers, R., Virtanen, P., Cournapeau, D., Wieser, E., Taylor, J., Berg, S., Smith, N. J., et al. (2020) · Nature · doi:10.1038/s41586-020-2649-2 · Cited by 23,826 · cited 1×
“The gaussian distributed 32,000 in-control internal QC results were generated using Python 3.7.6 [12]. with Numpy package 1.19.1 [13].”
MethodInfluentialHarris, C., Millman, K., van der Walt, S., Gommers, R., Virtanen, P., Cournapeau, D., Wieser, E., Taylor, J., Berg, S., Smith, N., et al. (2020) · RePEc: Research Papers in Economics · Cited by 17,844
PAGE, E. S. (1954) · Biometrika · doi:10.1093/biomet/41.1-2.100 · Cited by 5,739 · cited 1×
“Page developed the CUSUM chart in 1954 by plotting deviations of the measured values from the target value [6].”
MethodExponentially Weighted Moving Average Control Schemes: Properties and Enhancements
Lucas, J. M., & Saccucci, M. S. (1990) · Technometrics · doi:10.1080/00401706.1990.10484583 · Cited by 1,934 · cited 1×
“Robert fi rst presented the EWMA chart in 1959, created by calculating the weighted average of current and previous data [3].”
MethodEstimating classification error rate: Repeated cross-validation, repeated hold-out and bootstrap
Kim, J.-H. (2009) · Computational Statistics & Data Analysis · doi:10.1016/j.csda.2009.04.009 · Cited by 792
Internal quality control: planning and implementation strategies
Westgard, J. O. (2003) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1258/000456303770367199 · Cited by 172 · cited 4×
“The QC rules corresponding to the Ped of ≥ 0.9 were regarded as acceptable for an intended degree of systematic error [2].”
BackgroundMethodInfluentialThe Inertial Properties of Quality Control Charts
Woodall, W. H., & Mahmoud, M. A. (2005) · Technometrics · doi:10.1198/004017005000000256 · Cited by 154 · cited 1×
“Furthermore, the combined utility of EWMA and Shewhart chart (conventional QC rules) was recommended previously [19] due to the inertia effect that leads to a lag in error detection, particularly when a lower weighting factor is used [7].”
BackgroundWestgard, J. O., Groth, T., Aronsson, T., Falk, H., & de Verdier, C. H. (1977) · Clinical Chemistry · doi:10.1093/clinchem/23.10.1857 · Cited by 152 · cited 2×
“While these metrics are important for implementing proper QC strategy according to CLSI C24ed4, only a few old-dated studies [9, 10] investigated mostly conventional rules, and one study addressed the comparison of EWMA with conventional rules [11].”
BackgroundMethodInfluentialPower functions for statistical control rules.
Westgard, J. O., & Groth, T. (1979) · Clinical Chemistry · doi:10.1093/clinchem/25.6.863 · Cited by 144 · cited 1×
“While these metrics are important for implementing proper QC strategy according to CLSI C24ed4, only a few old-dated studies [9, 10] investigated mostly conventional rules, and one study addressed the comparison of EWMA with conventional rules [11].”
MethodCombined Shewhart-Cusum control chart for improved quality control in clinical chemistry
Westgard, J. O., Groth, T., Aronsson, T., & de Verdier, C. H. (1977) · Clinical Chemistry · doi:10.1093/clinchem/23.10.1881 · Cited by 138
Rosenbaum, M. W., Flood, J. G., Melanson, S. E. F., Baumann, N. A., Marzinke, M. A., Rai, A. J., Hayden, J. A., Wu, A. H. B., Ladror, M., Lifshitz, M. S., et al. (2018) · American Journal of Clinical Pathology · doi:10.1093/ajcp/aqy033 · Cited by 75 · cited 3×
“Surprisingly, Rosenbaum et al. [17] reported that 16 out of 21 clinical laboratories of the USA ’ s reputed academic centers used only 2 SD rule.”
BackgroundInfluentialInternal quality control: best practice
Kinns, H., Pitkin, S., Housley, D., & Freedman, D. B. (2013) · Journal of Clinical Pathology · doi:10.1136/jclinpath-2013-201661 · Cited by 66 · cited 1×
“…a laboratory professional may intend to detect systematic errors higher than 1.5 SD and substantial random errors, in this case, EWMA ( λ =0.2) may be preferred for preserving Ped ≥ 0.9, and may combine with the “ 1 – 3s ” rule which can cover random errors [20] while maintaining Pfr ≤ 0.05.”
MethodInfluentialExponentially Weighted Moving Average (EWMA) Control Charts for Monitoring an Analytical Process
Carson, P. K., & Yeh, A. B. (2007) · Industrial & Engineering Chemistry Research · doi:10.1021/ie070589b · Cited by 64 · cited 1×
“EWMA chart is superior to Shewhart ’ s graph for detecting small shifts from the target value, particularly when a lower weighting factor (0.05 – 0.2) is used [4, 5].”
MethodInfluentialUseful measures and models for analytical quality management in medical laboratories
Westgard, J. O. (2016) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2015-0710 · Cited by 64 · cited 1×
“Power graphs are also utilized to select suitable QC rules and the number of QC measurements according to measurement procedures performance [8].”
MethodLínnet, K. (2006) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2006.077 · Cited by 32 · cited 4×
“While these metrics are important for implementing proper QC strategy according to CLSI C24ed4, only a few old-dated studies [9, 10] investigated mostly conventional rules, and one study addressed the comparison of EWMA with conventional rules [11].”
MethodResultInfluentialShould I Repeat My 1:2s QC Rejection?
Parvin, C. A., Kuchipudi, L., & Yundt-Pacheco, J. C. (2012) · Clinical Chemistry · doi:10.1373/clinchem.2011.181818 · Cited by 23 · cited 1×
“The Pfr values of 1 – 2s and 1 – 3s were reported as 0.049 and 0.0020 by West-gard et al. [10] and 0.089 and 0.0054 by Parvin [21], respectively.”
BackgroundInfluentialThe weighting factor of exponentially weighted moving average chart
Çubukçu, H. C. (2020) · Turkish Journal of Biochemistry · doi:10.1515/tjb-2019-0368 · Cited by 4 · cited 2×
“However, original control limits and weighting factors of 0.2, 0.1, and 0.05 were utilized in the present study to fi t for its purpose of detecting trends and small systematic errors [5].”
MethodInfluentialSelf-citation
Research works printed but not linked: 1
- Introduction to statistical quality control. D C Montgomery, 2013John Wiley & SonsDanvers7th ed
Cited by
Machine learning-based clinical decision support using laboratory data
Çubukçu, H. C., Topcu, D. İ., & Yenice, S. (2024) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2023-1037 · Cited by 66
“However, the model lacked performance evaluation with multi rules and real-world implementation [40].”
BackgroundMethodSelf-citationÇubukçu, H. C., Boursier, G., Linko, S., Andreu, F. A. B., Brguljan, P. M., Trajkovska, K. T., Brugnoni, D., Milinković, N., Padoan, A., & Thelen, M. (2025) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2025-0482 · Cited by 40
Self-citationCadamuro, J. (2022) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2022-0620 · Cited by 33
Advances in clinical chemistry patient-based real-time quality control (PBRTQC)
Cervinski, M. A., Bietenbeck, A., Katayev, A., Loh, T. P., van Rossum, H. H., & Badrick, T. C. (2023) · Advances in clinical chemistry · doi:10.1016/bs.acc.2023.08.003 · Cited by 18
Çubukçu, H. C. (2024) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2024-0156 · Cited by 16
Self-citation
Metadata
- Authors
- Çubukçu, H. C.
- Affiliations
- Ankara University (TR)
- Corresponding author
- Çubukçu, Hikmet Can
- ORCID
- Çubukçu, Hikmet Can
- Venue
- Turkish Journal of Biochemistry
- Publisher
- Walter de Gruyter GmbH
- Published
- 2021-12-01
- Volume
- 46
- Issue
- 6
- Pages
- 661-670
- ISSN
- 0250-4685 (ISSN-L)
- 1303-829X
- OpenAlex
- W4200198924
- Cited by
- 13
- References
- 19
- Citations by year
- 2026: 4 · 2025: 4 · 2024: 2 · 2023: 2 · 2022: 1
- FWCI
- 0.79
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Locations
- Turkish Journal of Biochemistry (publishedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Advanced Statistical Process Monitoring
- Physical Sciences › Engineering › Control and Systems Engineering › Fault Detection and Control Systems
- Keywords
- internal quality control, random forest, EWMA control chart, CUSUM control chart, average run length, systematic error detection
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.