Abstract
Anatomical and physiological imaging using CT and MRI are playing a critical role in patients' diagnosis, disease characterization and treatment planning. CT- and MRI-based protocols increasingly require an injection of iodinated CT and gadolinium (Gd)-based MRI contrast media. Although routinely used in clinical practice, iodinated and to a less extent Gd-based contrast media possess side effects: life-threatening contrast-induced nephropathy (CIN) is associated with CT and nephrogenic systemic fibrosis (NSF) with MRI contrast agents. CIN is defined as an acute decline in renal functions (serum creatinine increase > 0.5 mg/dl) after administration of iodinated contrast media. Patients with moderate-to-severe chronic kidney disease are considered the highest risk group for development of CIN. CIN is more common with ionic high-osmolar contrast CT media. NSF is a rare condition characterized by the formation of connective tissue in the skin and systemically in the lung, liver, heart and kidney. Patients with end stage kidney disease, acute kidney injury and stage 4-5 chronic kidney disease are at a high risk for NSF. The nonionic linear Gd-chelates are associated with the highest risk of NSF. This review summarizes the incidence, symptoms, safety profile of various CT and MRI contrast agents based on their physiochemical properties.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Assessing Kidney Function — Measured and Estimated Glomerular Filtration Rate
Stevens, L. A., Coresh, J., Greene, T., & Levey, A. S. (2006) · New England Journal of Medicine · doi:10.1056/nejmra054415 · Cited by 2,952 · cited 1×
“73 m2) in young men and women, respectively [16].”
BackgroundMarckmann, P., Skov, L., Rossen, K., Dupont, A., Damholt, M. B., Heaf, J. G., & Thomsen, H. S. (2006) · Journal of the American Society of Nephrology · doi:10.1681/asn.2006060601 · Cited by 1,400 · cited 2×
“However, in January 2006, the first case of a lifethreatening disease, NSF, associated with the use of a Gd-based contrast agent has been announced [64,65].”
BackgroundWeissleder, R., & Mahmood, U. (2001) · Radiology · doi:10.1148/radiology.219.2.r01ma19316 · Cited by 1,315
Nephrotoxic Effects in High-Risk Patients Undergoing Angiography
Aspelin, P., Aubry, P., Fransson, S.-G., Strasser, R., Willenbrock, R., & Berg, K. J. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa021833 · Cited by 1,136 · cited 1×
“Finally, high concentrations of iodinated contrast media are necessary to provide differentiation of the blood architecture in X-ray-based angiography for coronary intervention studies [22-25].”
BackgroundGadolinium(iii) complexes as MRI contrast agents: ligand design and properties of the complexes
Hermann, P., Kotek, J., Kubíček, V., & Lukeš, I. (2008) · Dalton Transactions · doi:10.1039/b719704g · Cited by 530 · cited 10×
“The different physicochemical properties of Gd-based contrast agents affect the release of toxic free Gd3+. Gd-based contrast media that consist of ionic cyclic chelates with high thermodynamic stability and long dissociation half-lives are least likely to release free Gd ions into the body.”
BackgroundInfluentialDynamic Contrast-Enhanced Magnetic Resonance Imaging As an Imaging Biomarker
Hylton, N. (2006) · Journal of Clinical Oncology · doi:10.1200/jco.2006.06.8080 · Cited by 410 · cited 8×
“Other major applications of Gd-enhanced MRI include contrast-enhanced magnetic resonance angiography (MRA) and DCE-MRI for organ/lesion perfusion.”
BackgroundMethodInfluentialProphylaxis Strategies for Contrast-Induced Nephropathy
Pannu, N., Wiebe, N., Tonelli, M., & Alberta Kidney Disease Network, F. T. (2006) · JAMA · doi:10.1001/jama.295.23.2765 · Cited by 410 · cited 2×
“For prophylaxis, periprocedural hydration (the administration of fluids before, during and after the contrast) is the mainstay of CIN prevention [54-57].”
BackgroundIdée, J., Port, M., Raynal, I., Schaefer, M., Le Greneur, S., & Corot, C. (2006) · Fundamental & Clinical Pharmacology · doi:10.1111/j.1472-8206.2006.00447.x · Cited by 395 · cited 1×
“Some Gd-based contrast agents are more likely to release free Gd3+ through a process called transmetallation (using endogenous ions such as zinc and copper) [71,72].”
BackgroundPathophysiology of Contrast-Induced Nephropathy
Tumlin, J., Stacul, F., Adam, A., Becker, C. R., Davidson, C., Lameire, N., & McCullough, P. A. (2006) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2006.01.020 · Cited by 395
Trends in Adverse Events After IV Administration of Contrast Media
Cochran, S. T., Bomyea, K., & Sayre, J. W. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.6.1761385 · Cited by 358 · cited 3×
“The incidence of mild and moderate acute adverse reactions is higher for HOCM (4 – 12%) than for LOCM (1 – 3%) [35,38,48-50].”
BackgroundArtemov, D., Mori, N., Okollie, B., & Bhujwalla, Z. M. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10406 · Cited by 351 · cited 1×
“In addition, metabolic end points can be established with PET, single photon emission tomography and magnetic resonance spectroscopy protocol [10-14], and molecular biomarkers can be non-invasively followed up using PET and MRI-based molecular probes [3,14,15].”
BackgroundSolomon, R. J., Natarajan, M. K., Doucet, S., Sharma, S. K., Staniloae, C. S., Katholi, R. E., Gelormini, J. L., Labinaz, M., Moreyra, A. E., & the Investigators of the CARE Study (2007) · Circulation · doi:10.1161/circulationaha.106.671644 · Cited by 346 · cited 1×
“Finally, high concentrations of iodinated contrast media are necessary to provide differentiation of the blood architecture in X-ray-based angiography for coronary intervention studies [22-25].”
BackgroundFrequency, Outcome, and Appropriateness of Treatment of Nonionic Iodinated Contrast Media Reactions
Wang, C. L., Cohan, R. H., Ellis, J. H., Caoili, E. M., Wang, G., & Francis, I. R. (2008) · American Journal of Roentgenology · doi:10.2214/ajr.07.3421 · Cited by 306 · cited 3×
“The incidence of mild and moderate acute adverse reactions is higher for HOCM (4 – 12%) than for LOCM (1 – 3%) [35,38,48-50].”
BackgroundDillman, J. R., Ellis, J. H., Cohan, R. H., Strouse, P. J., & Jan, S. C. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.07.2554 · Cited by 303 · cited 1×
“Allergic reactions have also been reported [82-85].”
Iodinated Contrast Media and Their Adverse Reactions
Singh, J., & Daftary, A. (2008) · Journal of Nuclear Medicine Technology · doi:10.2967/jnmt.107.047621 · Cited by 293 · cited 4×
“The incidence of mild and moderate acute adverse reactions is higher for HOCM (4 – 12%) than for LOCM (1 – 3%) [35,38,48-50].”
BackgroundInfluentialSystematic review of the impact of N-acetylcysteine on contrast nephropathy
Pannu, N., Manns, B., Lee, H., & Tonelli, M. (2004) · Kidney International · doi:10.1111/j.1523-1755.2004.00516.x · Cited by 284 · cited 2×
“The use of free-radical scavenger N-acetylcysteine before contrast media administration also seems to be of rather borderline statistical significance for CIN prevention efficacy [58,59].”
BackgroundDynamic contrast-enhanced MRI as a predictor of tumour response to radiotherapy
Zahra, M. A., Hollingsworth, K. G., Sala, E., Lomas, D. J., & Tan, L. T. (2007) · The Lancet Oncology · doi:10.1016/s1470-2045(06)71012-9 · Cited by 272
Rydahl, C., Thomsen, H. S., & Marckmann, P. (2008) · Investigative Radiology · doi:10.1097/rli.0b013e31815a3407 · Cited by 252 · cited 11×
“The different physicochemical properties of Gd-based contrast agents affect the release of toxic free Gd3+. Gd-based contrast media that consist of ionic cyclic chelates with high thermodynamic stability and long dissociation half-lives are least likely to release free Gd ions into the body.”
BackgroundResultInfluentialExtracellular gadolinium-based contrast media: An overview
Bellin, M.-F., & Van Der Molen, A. J. (2008) · European Journal of Radiology · doi:10.1016/j.ejrad.2008.01.023 · Cited by 226 · cited 3×
“Most Gd-based contrast agents have pharmacokinetics similar to those of iodinated CT contrast media and are excreted exclusively by passive glomerular filtration through the kidney, without secretion or reabsorption [66].”
BackgroundMRI Safety Update 2008: Part 1, MRI Contrast Agents and Nephrogenic Systemic Fibrosis
Shellock, F. G., & Spinazzi, A. (2008) · American Journal of Roentgenology · doi:10.2214/ajr.08.1038.1 · Cited by 221 · cited 3×
“After the initial report, a significant amount of clinical studies and retrospective review reports have reported development of NSF in association with Gd-based chelate administration [72,74-81].”
BackgroundResultWang, C. L., Cohan, R. H., Ellis, J. H., Adusumilli, S., & Dunnick, N. R. (2007) · Radiology · doi:10.1148/radiol.2431060554 · Cited by 219 · cited 3×
“The incidence of mild and moderate acute adverse reactions is higher for HOCM (4 – 12%) than for LOCM (1 – 3%) [35,38,48-50].”
BackgroundResultBeer, A. J., Grosu, A.-L., Carlsen, J., Kolk, A., Sarbia, M., Stangier, I., Watzlowik, P., Wester, H.-J., Haubner, R., & Schwaiger, M. (2007) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-07-0528 · Cited by 217 · cited 1×
“In addition, metabolic end points can be established with PET, single photon emission tomography and magnetic resonance spectroscopy protocol [10-14], and molecular biomarkers can be non-invasively followed up using PET and MRI-based molecular probes [3,14,15].”
BackgroundAcute adverse reactions to magnetic resonance contrast media – gadolinium chelates
Li, A., Wong, C. S., Wong, M. K., Lee, C. M., & Au Yeung, M. C. (2006) · The British Journal of Radiology · doi:10.1259/bjr/88469693 · Cited by 217 · cited 1×
“Allergic reactions have also been reported [82-85].”
Incidence and Outcomes of Contrast-Induced AKI Following Computed Tomography
Weisbord, S. D., Mor, M. K., Resnick, A. L., Hartwig, K. C., Palevsky, P. M., & Fine, M. J. (2008) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.01260308 · Cited by 212 · cited 1×
“[43] reported CIN incidence in patients with eGFR < 60 ml/(min 1.”
BackgroundSolomon, R. (2005) · Kidney International · doi:10.1111/j.1523-1755.2005.00684.x · Cited by 209
Thomassin-Naggara, I., Bazot, M., Daraï, E., Callard, P., Thomassin, J., & Cuenod, C. A. (2008) · Radiology · doi:10.1148/radiol.2481071120 · Cited by 201 · cited 1×
“DCEMRI can be used for the non-invasive assessment of tumor vascular properties [5,27,28].”
MethodWertman, R., Altun, E., Martin, D. R., Mitchell, D. G., Leyendecker, J. R., O'Malley, R. B., Parsons, D. J., Fuller, E. R., & Semelka, R. C. (2008) · Radiology · doi:10.1148/radiol.2483072093 · Cited by 187 · cited 10×
“The different physicochemical properties of Gd-based contrast agents affect the release of toxic free Gd3+. Gd-based contrast media that consist of ionic cyclic chelates with high thermodynamic stability and long dissociation half-lives are least likely to release free Gd ions into the body.”
BackgroundInfluentialMRI Safety Update 2008: Part 2, Screening Patients for MRI
Shellock, F. G., & Spinazzi, A. (2008) · American Journal of Roentgenology · doi:10.2214/ajr.08.1038.2 · Cited by 171 · cited 2×
“After the initial report, a significant amount of clinical studies and retrospective review reports have reported development of NSF in association with Gd-based chelate administration [72,74-81].”
BackgroundResultTherapeutic Targets and Biomarkers Identified in Cancer Choline Phospholipid Metabolism
Glunde, K., & Serkova, N. J. (2006) · Pharmacogenomics · doi:10.2217/14622416.7.7.1109 · Cited by 159 · cited 1×
“In addition, metabolic end points can be established with PET, single photon emission tomography and magnetic resonance spectroscopy protocol [10-14], and molecular biomarkers can be non-invasively followed up using PET and MRI-based molecular probes [3,14,15].”
BackgroundSelf-citationLiss, P., Persson, P. B., Hansell, P., & Lagerqvist, B. (2006) · Kidney International · doi:10.1038/sj.ki.5001887 · Cited by 158 · cited 1×
“It has been shown that the incidence and severity of these adverse reactions is related to physical properties (osmolarity) of existing CT contrast agents [33,35-42].”
BackgroundDillman, J. R., Strouse, P. J., Ellis, J. H., Cohan, R. H., & Jan, S. C. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.1328 · Cited by 148
Nguyen, S. A., Suranyi, P. S., Ravenel, J. G., Randall, P. K., Romano, P. B., Strom, K. A., Costello, P., & Schoepf, U. J. (2008) · Radiology · doi:10.1148/radiol.2481071484 · Cited by 138 · cited 3×
“The incidence of CIN is estimated to be 2 – 7% in a general patient population [35], whereas in CKD patients (stage 3 with a GFR of < 60 ml/(min mvvm2)) it can reach up to 24% after intra-arterial administration of contrast media [36,37].”
BackgroundResultTheophylline for Prevention of Contrast-Induced Nephropathy
Bagshaw, S. M. (2005) · Archives of Internal Medicine · doi:10.1001/archinte.165.10.1087 · Cited by 137 · cited 2×
“The same situation exists for bronchodialators theophylline and aminophylline [60,61].”
BackgroundSnapshot Magnetic Resonance Imaging (Nobel Lecture)
Mansfield, P. R. (2004) · Angewandte Chemie International Edition · doi:10.1002/anie.200460078 · Cited by 128 · cited 1×
“When a signal in the form of a radio wave pulse is applied to the body using surface coils, atomic distribution between parallel and anti-parallel alignment is changed, and after the pulse is gone, the system relaxes to its original status [4,26].”
BackgroundCruz, D. N., Perazella, M. A., Bellomo, R., Corradi, V., de Cal, M., Kuang, D., Ocampo, C., Nalesso, F., & Ronco, C. (2006) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2006.05.023 · Cited by 127
Contrast-induced nephropathy: the wheel has turned 360 degrees
Thomsen, H. S., Morcos, S. K., & Barrett, B. J. (2008) · Acta Radiologica · doi:10.1080/02841850801995413 · Cited by 125 · cited 1×
“CIN is defined as an acute decline in renal functions following administration of iodinated contrast media with no other known cause and is responsible for > 10% of cases of hospital-acquired renal insufficiency with significant morbidity and mortality [17-19].”
BackgroundBagshaw, S. M., & Ghali, W. A. (2004) · BMC Medicine · doi:10.1186/1741-7015-2-38 · Cited by 119
Molecular framework for response to imatinib mesylate in systemic sclerosis
Chung, L., Fiorentino, D. F., BenBarak, M. J., Adler, A. S., Mariano, M. M., Paniagua, R. T., Milano, A., Connolly, M. K., Ratiner, B. D., Wiskocil, R. L., et al. (2009) · Arthritis & Rheumatism · doi:10.1002/art.24221 · Cited by 118
Safety of Magnetic Resonance Contrast Media
Runge, V. M. (2001) · Topics in Magnetic Resonance Imaging · doi:10.1097/00002142-200108000-00007 · Cited by 116 · cited 1×
“Cyclic molecules provide better protection and binding to Gd3+ compared with linear molecules [70].”
BackgroundThomsen, H. S., & Morcos, S. K. (1999) · European Radiology · doi:10.1007/s003300050746 · Cited by 114
Thomsen, H. S. (2007) · Cancer Imaging · doi:10.1102/1470-7330.2007.0019 · Cited by 110 · cited 10×
“The different physicochemical properties of Gd-based contrast agents affect the release of toxic free Gd3+. Gd-based contrast media that consist of ionic cyclic chelates with high thermodynamic stability and long dissociation half-lives are least likely to release free Gd ions into the body.”
BackgroundInfluentialReilly, R. F. (2008) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.05721207 · Cited by 107 · cited 1×
“Hemodialysis can be potentially beneficiary if performed early, especially for patients who undergo several enhanced MRI sessions [73].”
BackgroundEditorial: Gadolinium Use in Patients with Kidney Disease: A Cause for Concern
Perazella, M. A., & Rodby, R. A. (2007) · Seminars in Dialysis · doi:10.1111/j.1525-139x.2007.00269.x · Cited by 92 · cited 2×
“Some Gd-based contrast agents are more likely to release free Gd3+ through a process called transmetallation (using endogenous ions such as zinc and copper) [71,72].”
BackgroundResponse to the FDA's May 23, 2007, Nephrogenic Systemic Fibrosis Update
Kanal, E., Broome, D. R., Martín, D. R., & Thomsen, H. S. (2007) · Radiology · doi:10.1148/radiol.2461071267 · Cited by 91 · cited 11×
“The different physicochemical properties of Gd-based contrast agents affect the release of toxic free Gd3+. Gd-based contrast media that consist of ionic cyclic chelates with high thermodynamic stability and long dissociation half-lives are least likely to release free Gd ions into the body.”
BackgroundResultInfluentialDillman, J. R., Ellis, J. H., Cohan, R. H., Strouse, P. J., & Jan, S. C. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.07.2718 · Cited by 73 · cited 1×
“Allergic reactions have also been reported [82-85].”
Functional magnetic resonance imaging of the kidney using macromolecular contrast agents
Choyke, P. L., & Kobayashi, H. (2005) · Abdominal Imaging · doi:10.1007/s00261-005-0390-9 · Cited by 52 · cited 6×
“Other major applications of Gd-enhanced MRI include contrast-enhanced magnetic resonance angiography (MRA) and DCE-MRI for organ/lesion perfusion.”
BackgroundInfluentialImaging in the time of NFD/NSF: do we have to change our routines concerning renal insufficiency?
Bongartz, G. (2007) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-007-0071-5 · Cited by 51 · cited 2×
“8; dissociation half-life 30s) exposure [69], followed by ionic linear gadopentetate dimeglumine (Magnevist®: thermodynamic stability 16.”
BackgroundBoss, A., Martirosian, P., Gehrmann, M., Artunç, F., Risler, T., Oesingmann, N., Claussen, C. D., Schick, F., Küper, K., & Schlemmer, H.-P. (2007) · Radiology · doi:10.1148/radiol.2423060209 · Cited by 49
Prevention of contrast-induced nephropathy: a critical review
Praet, J. T. V., & Vriese, A. S. D. (2007) · Current Opinion in Nephrology & Hypertension · doi:10.1097/mnh.0b013e3281ca6fe5 · Cited by 48
Bisdas, S., Medov, L., Baghi, M., Konstantinou, G. Ν., Wagenblast, J., Thng, C. H., Vogl, T. J., & Koh, T. S. (2008) · European Radiology · doi:10.1007/s00330-007-0827-3 · Cited by 46
Troiani, T., Serkova, N. J., Gustafson, D. L., Henthorn, T. K., Lockerbie, O., Merz, A. L., Long, M., Morrow, M., Ciardiello, F., & Eckhardt, S. G. (2007) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-07-1094 · Cited by 44
Self-citationNephrogenic Systemic Fibrosis and Gadolinium: A Perfect Storm
Colletti, P. M. (2008) · American Journal of Roentgenology · doi:10.2214/ajr.08.1327 · Cited by 35 · cited 1×
“However, in January 2006, the first case of a lifethreatening disease, NSF, associated with the use of a Gd-based contrast agent has been announced [64,65].”
BackgroundContrast-induced nephropathy: epidemiology and prevention.
Bagshaw, S. M., & Culleton, B. F. (2006) · PubMed · Cited by 31
Comparative cytotoxicity of high-osmolar and low-osmolar contrast media on HKCs in vitro.
Duan, S.-B., Zhou, X., Liu, F., et al. (2007) · PubMed · Cited by 26
Comparative Tolerability of Contrast Media Used for Coronary Interventions
Esplugas, E., Cequier, A. R., del Blanco, B. G., & Jara, F. (2002) · Drug Safety · doi:10.2165/00002018-200225150-00003 · Cited by 25 · cited 1×
“Finally, high concentrations of iodinated contrast media are necessary to provide differentiation of the blood architecture in X-ray-based angiography for coronary intervention studies [22-25].”
Background
Cited by
X-ray-Computed Tomography Contrast Agents
Lusic, H., & Grinstaff, M. W. (2013) · Chemical Reviews · doi:10.1021/cr200358s · Cited by 1,108
Multimodality Imaging Probes: Design and Challenges
Louie, A. (2010) · Chemical Reviews · doi:10.1021/cr9003538 · Cited by 1,044
Jeon, M., Halbert, M. V., Stephen, Z. R., & Zhang, M. (2021) · Advanced Materials · doi:10.1002/adma.201906539 · Cited by 477
Self-microemulsifying drug delivery system (SMEDDS) – challenges and road ahead
Dokania, S., & Joshi, A. K. (2015) · Drug Delivery · doi:10.3109/10717544.2014.896058 · Cited by 337
Frequency, Outcome, and Appropriateness of Treatment of Nonionic Iodinated Contrast Media Reactions
Wang, C. L., Cohan, R. H., Ellis, J. H., Caoili, E. M., Wang, G., & Francis, I. R. (2008) · American Journal of Roentgenology · doi:10.2214/ajr.07.3421 · Cited by 306
Metadata
- Authors
- Hasebroock, K. M., & Serkova, N. J.
- Venue
- Expert Opinion on Drug Metabolism & Toxicology
- Publisher
- Informa UK Limited
- Published
- 2009-04
- Volume
- 5
- Issue
- 4
- Pages
- 403-416
- ISSN
- 1742-5255 (ISSN-L)
- 1744-7607
- OpenAlex
- W2055509312
- Cited by
- 242
- References
- 55
- FWCI
- 4.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.