Wearable Lactate Threshold Predicting Device is Valid and Reliable in Runners
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index; none of the 10 sources its claims cite is checked for support yet.
Abstract
Borges, NR and Driller, MW. Wearable lactate threshold predicting device is valid and reliable in runners. J Strength Cond Res 30(8): 2212–2218, 2016—A commercially available device claiming to be the world's first wearable lactate threshold predicting device (WLT), using near-infrared LED technology, has entered the market. The aim of this study was to determine the levels of agreement between the WLT-derived lactate threshold workload and traditional methods of lactate threshold (LT) calculation and the interdevice and intradevice reliability of the WLT. Fourteen (7 male, 7 female; mean ± SD ; age: 18–45 years, height: 169 ± 9 cm, mass: 67 ± 13 kg, V̇ o 2 max: 53 ± 9 ml·kg −1 ·min −1 ) subjects ranging from recreationally active to highly trained athletes completed an incremental exercise test to exhaustion on a treadmill. Blood lactate samples were taken at the end of each 3-minute stage during the test to determine lactate threshold using 5 traditional methods from blood lactate analysis which were then compared against the WLT predicted value. In a subset of the population ( n = 12), repeat trials were performed to determine both inter-reliability and intrareliability of the WLT device. Intraclass correlation coefficient (ICC) found high to very high agreement between the WLT and traditional methods (ICC > 0.80), with TEMs and mean differences ranging between 3.9–10.2% and 1.3–9.4%. Both interdevice and intradevice reliability resulted in highly reproducible and comparable results (CV < 1.2%, TEM <0.2 km·h −1 , ICC > 0.97). This study suggests that the WLT is a practical, reliable, and noninvasive tool for use in predicting LT in runners.
Overview
CoChat Summary
TL;DR
The wearable lactate threshold predicting device (WLT; BSXinsight multisport edition) showed no significant differences from five traditional blood lactate methods for treadmill workload at lactate threshold and had high test-retest and interdevice reliability in runners. It was most closely correlated with the 4 mmol/L method, though it tended to slightly overestimate LT workload compared with traditional methods.
Key findings
- One-way ANOVA found no statistically significant differences between LT workloads determined by the WLT and traditional methods (p = 0.60); ICCs ranged from 0.80 to 0.98.
- Highest agreement was with the 4 mmol/L method: ICC = 0.98, TEM = 0.48 km/h (3.9%), mean difference = 0.18 km/h (1.3%), 95% limits of agreement −0.82 to 1.18 km/h.
- Interdevice reliability (2 devices during one test, n = 12): CV = 1.2% (0.9–2.1), TEM = 0.16 km/h (0.12–0.28), ICC = 0.97 (0.90–0.99); intradevice reliability (same device, two tests ~24 h apart): CV = 1.2% (0.9–2.1), TEM = 0.16 km/h (0.11–0.27), ICC = 0.97 (0.90–0.99).
- The WLT tended to overestimate LT workload versus traditional methods; Bland-Altman plots showed outliers versus Dmax and modified Dmax and a downward trend versus the 1 mmol/L method with increasing workload.
Methods
- Validity/reliability study in 14 runners (7 male, 7 female; VO2max range 39.7–67.0 ml/kg/min; LT speeds 10.9–16.2 km/h); reliability subset n = 12.
- Treadmill graded exercise test to exhaustion with 3-minute stages set by WLT software, warm-up at 4.8 km/h, second stage 9.3–11.7 km/h, increments 0.3–1.1 km/h until the subject could not maintain the workload; minimum 4 stages required. Blood lactate was collected by finger-prick capillary samples in the final 10 seconds of each stage and 1 minute postexercise; the WLT NIRS device was fitted over the gastrocnemius.
- Traditional LT methods: linear spline fitting, Dmax, modified Dmax, fixed 4 mmol/L, and first rise >1 mmol/L. Analysis used 1-way ANOVA, ICC with 95% CI, TEM, Bland-Altman plots; reliability data were log-transformed and reported as CV%, TEM, and ICC.
Limitations
- Stated: the patented WLT design and algorithm make the exact LT prediction methodology difficult to evaluate; this is the first study comparing the WLT with traditional methods, so direct comparisons with existing research are difficult; heterogeneous NIRS methodology (device, measurement site, parameter) may affect compatibility of results.
- Stated: the range of LT values produced by traditional methods (12.3–13.3 km/h) makes it difficult to conclude whether the WLT provides a valid prediction of LT; the WLT showed small overestimation and method-dependent agreement (outliers vs Dmax/modified Dmax, trend vs 1 mmol/L).
- Evident: small sample (14 total; 12 reliability) and testing limited to treadmill running, gastrocnemius placement, and threshold range 10.9–16.2 km/h, which may limit generalizability.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 8 Not checked · 23 Own results and interpretations
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“One-way ANOVA showed no statistically significant differences between the LT workloads determined by the different methods (p = 0.60).”
§ Wearable Lactate Threshold Predicting Device is Valid and Reliable in Runners > RESULTS
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Rests on an assumption not shown here.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Intraclass correlation coefficients with 95% CI ranged from 0.80 to 0.98 (20.10 to 0.99) for workload at LT calculated by the WLT and traditional methods, and are shown in Table 1.”
§ Wearable Lactate Threshold Predicting Device is Valid and Reliable in Runners > RESULTS
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Rests on an assumption not shown here.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“When comparing the interdevice reliability during a single test in 12 separate trials, the WLT resulted in a CV and 95% CI of 1.2% (0.9-2.1), a TEM of 0.16 km$h 21 (0.12-0.28) and an ICC of 0.97 (0.90-0.99).”
§ Wearable Lactate Threshold Predicting Device is Valid and Reliable in Runners > RESULTS
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“However, this magnitude of agreement was not apparent with all traditional methods.”
§ Wearable Lactate Threshold Predicting Device is Valid and Reliable in Runners > DISCUSSION
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Rests on an assumption not shown here.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Although showing high levels of agreement through ICCs, mean difference values reveal a tendency of the WLT to overestimate LT workload when compared with traditional methods (Figure 3).”
§ Wearable Lactate Threshold Predicting Device is Valid and Reliable in Runners > DISCUSSION
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Rests on an assumption not shown here.
7 more claims
Create a free account to see all 31 claims and every source verdict.
- It may state two separate claims as one. 13
- Probably not a substantial claim. 10
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“BSX Insight, which determines the threshold by making a comparison with blood lactate concentration, presented good values of ICC, although this used a patented method to determine MOT based on the inflection point of SmO2 during incremental testing45.”
From Reliability of threshold determination using portable muscle oxygenation monitors during exercise testing: a systematic review and meta-analysis (2023) · cites this paper as [45]
In the citing paper
“The articles included in this systematic review use different methods for determining thresholds: BSX Insight (20%, N = 3)45,47,49, double linear regression (46%, N = 7)16,26,39,41–44, visual method17,25,40, Dmax or modified Dmax46 and applications of devices Humon Beta48.”
From Reliability of threshold determination using portable muscle oxygenation monitors during exercise testing: a systematic review and meta-analysis (2023) · cites this paper as [45]
In the citing paper
“The second threshold was determined using the blood lactate concentration and muscle oxygenation in different sports such as cycling16,17,46–48, running44,45,49 and rowing26.”
From Reliability of threshold determination using portable muscle oxygenation monitors during exercise testing: a systematic review and meta-analysis (2023) · cites this paper as [45]
In the citing paper
“Vastus lateralis was the muscle most assessed16,25,26,40–44,46, although other muscles such as gastrocnemius44,45,47,49, rectus femoris17, biceps femoris44, lateral deltoid43 or intercostal39 were also evaluated.”
From Reliability of threshold determination using portable muscle oxygenation monitors during exercise testing: a systematic review and meta-analysis (2023) · cites this paper as [45]
In the citing paper
“Some of the articles included in this review demonstrate mean bias between MOT2 and LT2 or VT2 ranging from 0.01 and 0.4 km·h−125,44,45,49, between 3.9 and 15.4 W39,41, 0.05 W·kg−117 and 10.7% of the power output26.”
From Reliability of threshold determination using portable muscle oxygenation monitors during exercise testing: a systematic review and meta-analysis (2023) · cites this paper as [45]
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Endurance exercise performance: the physiology of champions
Joyner, M. J., & Coyle, E. F. (2008) · The Journal of Physiology · doi:10.1113/jphysiol.2007.143834 · Cited by 1,307 · cited 1×
“Alongside a high V_ O2max and efficiency, a high LT is essential for endurance performance as it allows an athlete to perform at a higher work-rate for an extended duration (19).”
BackgroundMonitoring tissue oxygen availability with near infrared spectroscopy (NIRS) in health and disease
Boushel, R., Langberg, H., Olesen, J., Gonzales‐Alonzo, J., Bülow, J., & Kjær, M. (2001) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1034/j.1600-0838.2001.110404.x · Cited by 469 · cited 1×
“Although the use of NIRS is relatively new to sports science, it has proven to be a viable noninvasive tool to determine peripheral muscle oxygenation during exercise (4,22).”
MethodGrassi, B., Pogliaghi, S., Rampichini, S., Quaresima, V., Ferrari, M., Marconi, C., & Cerretelli, P. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00695.2002 · Cited by 429 · cited 5×
“This study provides the first data on the validity and reliability of the WLT’s ability to predict lactate threshold in runners.”
ResultInfluentialA New Approach for the Determination of Ventilatory and Lactate Thresholds
Cheng, B., Kuipers, H., Snyder, A., Keizer, H., Jeukendrup, A., & Hesselink, M. (1992) · International Journal of Sports Medicine · doi:10.1055/s-2007-1021309 · Cited by 371 · cited 2×
“Cond Res 30(8): 2212–2218, 2016—A commercially avail-”
MethodEvaluation of three portable blood lactate analysers: Lactate Pro, Lactate Scout and Lactate Plus
Tanner, R. K., Fuller, K. L., & Ross, M. L. R. (2010) · European Journal of Applied Physiology · doi:10.1007/s00421-010-1379-9 · Cited by 274 · cited 1×
“2% (26), an intradevice and interdevice CVof ;1.”
BackgroundBlood lactate accumulation and muscle deoxygenation during incremental exercise
Grassi, B., Quaresima, V., Marconi, C., Ferrari, M., & Cerretelli, P. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.87.1.348 · Cited by 248 · cited 7×
“This study provides the first data on the validity and reliability of the WLT’s ability to predict lactate threshold in runners.”
BackgroundInfluentialAccuracy and reliability of the ParvoMedics TrueOne 2400 and MedGraphics VO2000 metabolic systems
Crouter, S. E., Antczak, A., Hudak, J. R., DellaValle, D. M., & Haas, J. D. (2006) · European Journal of Applied Physiology · doi:10.1007/s00421-006-0255-0 · Cited by 240 · cited 1×
“Given, it has been suggested that a CV of ,10% is acceptable for reliability in other sport science measurement tools (1), such as metabolic analyzers (9), and the intradevice and interdevice CV of the one of the most commonly used blood lactate analyzers (Lactate Pro; Arkray Global Business Inc.”
MethodTest Validation in Sport Physiology: Lessons Learned From Clinimetrics
Impellizzeri, F. M., & Marcora, S. M. (2009) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.4.2.269 · Cited by 210
Blood lactate parameters related to aerobic capacity and endurance performance
Yoshida, T., Chida, M., Ichioka, M., & Suda, Y. (1987) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00696368 · Cited by 183 · cited 1×
“F or decades, lactate threshold (LT) has been utilized by endurance athletes as a key performance predictor and to dictate training practices (29).”
MethodPhysiological Responses to Shuttle Repeated-Sprint Running
Buchheit, M., Bishop, D., Haydar, B., Nakamura, F. Y., & Ahmaidi, S. (2010) · International Journal of Sports Medicine · doi:10.1055/s-0030-1249620 · Cited by 163 · cited 1×
“With further technological advancements, the use of portable NIRS systems to monitor peripheral muscle oxygenation in field testing has become more common (6).”
Software for calculating blood lactate endurance markers
Newell, J., Higgins, D., Madden, N., Cruickshank, J., Einbeck, J., McMillan, K., & McDonald, R. (2007) · Journal of Sports Sciences · doi:10.1080/02640410601128922 · Cited by 156 · cited 2×
“All LT workload calculations have also been previously described (23).”
BackgroundMethodMotion Artifact Removal for Functional Near Infrared Spectroscopy: A Comparison of Methods
Robertson, F. C., Douglas, T. S., & Meintjes, E. M. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2038667 · Cited by 148 · cited 1×
“Additionally, there is a high prevalence of cycle ergometer studies in existing research which is most likely a result of the possible increase in signal noise owing to movement artifact of the NIRS leads while running (25).”
BackgroundVerification of the heart rate threshold
Bunc, V., Hofmann, P., Leitner, H., & Gaisl, G. (1995) · European Journal of Applied Physiology · doi:10.1007/bf00238574 · Cited by 91 · cited 1×
“To circumvent the invasive nature of calculating ex ercise threshold workloads from blood lactate concentration, researchers have investigate d the use of expired gas (8), and to a lesser extent heart rate (7) inflection points and rating of perceived exertion scores (10) as means for determining exercise thresholds.”
MethodDetection of ventilatory threshold using near infrared spectroscopy in men and women
BHAMBHANI, Y. N., BUCKLEY, S. M., & SUSAKI, T. (1997) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199703000-00017 · Cited by 89 · cited 3×
“However, previous studies investigating the suitability of muscle oxygenation breakpoints using other NIRS systems to determine exercise thresholds have shown similar results to those of the present study (2,3,27).”
BackgroundResultApplication of Near Infrared Spectroscopy to Exercise Sports Science
Neary, J. P. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-032 · Cited by 73 · cited 1×
“Although the use of NIRS is relatively new to sports science, it has proven to be a viable noninvasive tool to determine peripheral muscle oxygenation during exercise (4,22).”
MethodDetermination of Maximal Lactate Steady State in Healthy Adults: Can NIRS Help?
BELLOTTI, C., CALABRIA, E., CAPELLI, C., & POGLIAGHI, S. (2013) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182828ab2 · Cited by 65 · cited 9×
“This study provides the first data on the validity and reliability of the WLT’s ability to predict lactate threshold in runners.”
BackgroundResultInfluentialWhich common NIRS variable reflects muscle estimated lactate threshold most closely?
Wang, L., Yoshikawa, T., Hara, T., Nakao, H., Suzuki, T., & Fujimoto, S. (2006) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/h06-069 · Cited by 54 · cited 9×
“This study provides the first data on the validity and reliability of the WLT’s ability to predict lactate threshold in runners.”
BackgroundInfluentialA Novel Approach for Lactate Threshold Assessment Based on Rating of Perceived Exertion
Fabre, N., Mourot, L., Zerbini, L., Pellegrini, B., Bortolan, L., & Schena, F. F. (2013) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.8.3.263 · Cited by 36 · cited 1×
“To circumvent the invasive nature of calculating exercise threshold workloads from blood lactate concentration, researchers have investigated the use of expired gas (8), and to a lesser extent heart rate (7) inflection points and rating of perceived exertion scores (10) as means for determining exercise thresholds.”
Method(2012) · Europe PMC (PubMed Central) · Cited by 23
Rao, R. P., Danduran, M. J., Loomba, R. S., Dixon, J. E., & Hoffman, G. M. (2012) · Pediatric Cardiology · doi:10.1007/s00246-012-0217-8 · Cited by 14 · cited 1×
“ventilatory thresholds (VT) (3,20,24,30) with only a handful of studies comparing NIRS inflection points to blood LTs (2,13,28).”
BackgroundPortable muscle oxygenation monitor based on near infrared spectroscopy
Zhang, Z., Wang, B., Qing, N., Luo, Q., & Gong, H. (2009) · Frontiers of Optoelectronics in China · doi:10.1007/s12200-009-0050-8 · Cited by 12 · cited 1×
“ventilatory thresholds (VT) (3,20,24,30) with only a handful of studies comparing NIRS inflection points to blood LTs (2,13,28).”
BackgroundKaratzanos, E., Paradisis, G. P., Zacharogiannis, E. G., Tziortzis, S., & Nanas, S. (2009) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2009.02.003 · Cited by 9 · cited 1×
“ventilatory thresholds (VT) (3,20,24,30) with only a handful of studies comparing NIRS inflection points to blood LTs (2,13,28).”
BackgroundFujimoto, S., Yoshikawa, T., Tateishi, Y., Wang, L., Hara, T., Mimura, T., Nakao, H., & Hirata, K. (2007) · The Journal of Japanese College of Angiology · Cited by 7
Research works printed but not linked: 1
- What is an acceptable amount of measurement error? The application of meaningful "analytical goals" to the reliability of sports science measurements made on a ratio scale. G Atkinson, A Nevill, B Edwards, J Sports Sci. 1718Atkinson, G, Nevill, A, and Edwards, B. What is an acceptable amount of measurement error? The application of meaningful "analytical goals" to the reliability of sports science measurements made on a ratio scale. J Sports Sci 17: 18, 1999.
Cited by
Peake, J. M., Kerr, G., & Sullivan, J. P. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.00743 · Cited by 523
“The BSX Insight wearable sleeve has been tested independently (Borges and Driller, 2016).”
MethodWearable Training-Monitoring Technology: Applications, Challenges, and Opportunities
Cardinale, M., & Varley, M. C. (2017) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2016-0423 · Cited by 221
Muscle Oximetry in Sports Science: A Systematic Review
Perrey, S., & Ferrari, M. (2018) · Sports Medicine · doi:10.1007/s40279-017-0820-1 · Cited by 220
Dose-Response Matters! - A Perspective on the Exercise Prescription in Exercise-Cognition Research
Herold, F., Müller, P., Gronwald, T., & Müller, N. G. (2019) · Frontiers in Psychology · doi:10.3389/fpsyg.2019.02338 · Cited by 196
Van Hooren, B., Goudsmit, J., Restrepo, J., & Vos, S. (2020) · Journal of Sports Sciences · doi:10.1080/02640414.2019.1690960 · Cited by 141
Metadata
- Authors
- Borges, N. R., & Driller, M. W.
- Affiliations
- Central Queensland University (AU)
- University of Waikato (NZ)
- Corresponding author
- Borges, Nattai R.
- Venue
- Journal of Strength and Conditioning Research
- Published
- 2016-08
- Volume
- 30
- Issue
- 8
- Pages
- 2212-2218
- ISSN
- 1064-8011 (ISSN-L)
- OpenAlex
- W2319419678
- Semantic Scholar
- cd8dc0d61aa1e4620865d8d6f4b3ac19eb7f0cea
- Cited by
- 59
- References
- 23
- Citations by year
- 2026: 5 · 2025: 5 · 2024: 8 · 2023: 3 · 2022: 7 · 2021: 6 · 2020: 4 · 2019: 6 · 2018: 7 · 2017: 4 · 2016: 4
- FWCI
- 4.93
- Type
- journal article
- Language
- en
- Open access
- green
- figshare.com
- Licence
- cc-by
- Locations
- The Journal of Strength and Conditioning Research (publishedVersion)
- PubMed (publishedVersion)
- Acquire (CQUniversity) (submittedVersion)
- Figshare (submittedVersion, cc-by)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Physical Sciences › Engineering › Biomedical Engineering › Lower Extremity Biomechanics and Pathologies
- Keywords
- lactate threshold, near-infrared LEDs, runners, incremental exercise test, blood lactate, device reliability, inter-device agreement, treadmill running, endurance training
- MeSH terms
- Adolescent, Adult, Exercise Test, Female, Humans, Male, Middle Aged, Running, Reproducibility of Results, Anaerobic Threshold, Biomarkers, Spectroscopy, Near-Infrared, Lactic Acid, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-23, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-23 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.