The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Concurrent Validity of Wearable Activity Trackers Under Free-Living Conditions
Abstract
Brooke, SM, An, H-S, Kang, S-K, Noble, JM, Berg, KE, and Lee, J-M. Concurrent validity of wearable activity trackers under free-living conditions. J Strength Cond Res 31(4): 1097–1106, 2017—The purpose of this study is to evaluate the concurrent validity of wearable activity trackers in energy expenditure (EE) and sleep period time (SPT) under free-living conditions. Ninety-five (28.5 ± 9.8 years) healthy men ( n = 34) and women ( n = 61) participated in this study. The total EE and SPT were measured using 8 monitors: Nike+ FuelBand SE (NFB), Garmin VivoFit (VF), Misfit Shine (MF), Fitbit Flex (FF), Jawbone UP (JU), Polar Loop (PL), Fitbit Charge HR (FC), and SenseWear Armband Mini (SWA) (criterion measures: SWA for EE and a sleep log for SPT). The mean absolute percent error (MAPE) for EE was 13.0, 15.2, 15.5, 16.1, 16.2, 22.8, and 24.5% for PL, MF, FF, NFB, FC, JU, and VF, respectively. Mean absolute percent errors were calculated for SPT to be 4.0, 8.8, 10.2, 11.5, 12.9, 13.6, 17.5, and 21.61% for VF, FF, JU, FC, MF, SWA laying down, PL, and SWA, respectively. Concurrent validity was examined using equivalence testing on EE (equivalence zone: 2,889.7–3,531.9 kcal); 2 trackers fell short of falling in the zone: PL (2,714.4–3,164.8 kcal) and FC (2,473.8–3,066.5 kcal). For SPT (equivalence zone: 420.6–514.0 minutes), several monitors fell in the zone: PL (448.3–485.6 minutes), MS (442.8–492.2 minutes), and FF (427.7–486.7 minutes). This study suggests that the PL and FC provide a reasonable estimate of EE under free-living conditions. The PL, FC, and MF were the most valid monitors used for measuring SPT.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“however, in systematic reviews, Fitbits outperform other commercially available devices when correlated with research-grade devices25,26.”
From Association of step counts over time with the risk of chronic disease in the All of Us Research Program (2022) · cites this paper as [25]
In the citing paper
“Nine studies (22 comparisons) examined energy expenditure in free-living settings compared with the criterion measures of doubly labeled water [104] and accelerometry [29,49,79,101,131,172,174,175].”
From Reliability and Validity of Commercially Available Wearable Devices for Measuring Steps, Energy Expenditure, and Heart Rate: Systematic Review (2020) · cites this paper as [79]
Citations
Cites
Health benefits of physical activity: the evidence
Warburton, D. E. R. (2006) · Canadian Medical Association Journal · doi:10.1503/cmaj.051351 · Cited by 8,007
Gangwisch, J. E., Heymsfield, S. B., Boden-Albala, B., Buijs, R. M., Kreier, F., Pickering, T. G., Rundle, A. G., Zammit, G. K., & Malaspina, D. (2006) · Hypertension · doi:10.1161/01.hyp.0000217362.34748.e0 · Cited by 1,284
Luyster, F. S., Strollo, P. J., Zee, P. C., & Walsh, J. K. (2012) · SLEEP · doi:10.5665/sleep.1846 · Cited by 923
Ferguson, T., Rowlands, A. V., Olds, T., & Maher, C. (2015) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-015-0201-9 · Cited by 468
Accuracy of Armband Monitors for Measuring Daily Energy Expenditure in Healthy Adults
Johannsen, D. L., Calabro, M. A., Stewart, J. W., Franke, W. D., Rood, J. C., & Welk, G. J. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181e0b3ff · Cited by 433
Validity of Consumer-Based Physical Activity Monitors
LEE, J.-M., KIM, Y., & WELK, G. J. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000287 · Cited by 401 · cited 2×
“Many of the wearable activity trackers have been validated during specific activities in laboratory settings (2,14), but to our best knowledge, although Ferguson et al.”
BackgroundMethodSelf-citationAssessing Physical Activity Using Wearable Monitors: Measures of Physical Activity
BUTTE, N. F., EKELUND, U., & WESTERTERP, K. R. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182399c0e · Cited by 359 · cited 1×
“cal, and mediolateral), which measure frequency, intensity, and duration of PA and sleep (6).”
BackgroundDirect Comparison of Two New Actigraphs and Polysomnography in Children and Adolescents
Meltzer, L. J., Walsh, C. M., Traylor, J. T., & Westin, A. M. L. (2011) · SLEEP · doi:10.5665/sleep.1608 · Cited by 339
Movement toward a novel activity monitoring device
Montgomery-Downs, H. E., Insana, S. P., & Bond, J. A. (2012) · Sleep and Breathing · doi:10.1007/s11325-011-0585-y · Cited by 301
Validity of Activity-Based Devices to Estimate Sleep
Weiss, A. R., Johnson, N. L., Berger, N. A., & Redline, S. S. (2010) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27874 · Cited by 225
Flagged first, then by citations
Research works printed but not linked: 2
- Danova, 2015, The Wearables Report: Growth trends, consumer attitudes, and why smartwatches will dominate, Business Insider, 21
- Llamas, IDC worldwide quarterly mobile phone tracker, IDC, Tech Rep
Cited by
Sorted by citations
Fuller, D., Colwell, E., Low, J., Orychock, K., Tobin, M. A., Simango, B., Buote, R., Van Heerden, D., Luan, H., Cullen, K., et al. (2020) · JMIR mHealth and uHealth · doi:10.2196/18694 · Cited by 715
Accuracy of Fitbit Devices: Systematic Review and Narrative Syntheses of Quantitative Data
Feehan, L. M., Geldman, J., Sayre, E. C., Park, C., Ezzat, A. M., Yoo, J. Y., Hamilton, C. B., & Li, L. C. (2018) · JMIR mHealth and uHealth · doi:10.2196/10527 · Cited by 616
Henriksen, A., Haugen Mikalsen, M., Woldaregay, A. Z., Muzny, M., Hartvigsen, G., Hopstock, L. A., & Grimsgaard, S. (2018) · Journal of Medical Internet Research · doi:10.2196/jmir.9157 · Cited by 542
Accuracy of Wristband Fitbit Models in Assessing Sleep: Systematic Review and Meta-Analysis
Haghayegh, S., Khoshnevis, S., Smolensky, M. H., Diller, K. R., & Castriotta, R. J. (2019) · Journal of Medical Internet Research · doi:10.2196/16273 · Cited by 446
Master, H., Annis, J., Huang, S., Beckman, J. A., Ratsimbazafy, F., Marginean, K., Carroll, R., Natarajan, K., Harrell, F. E., Roden, D. M., et al. (2022) · Nature Medicine · doi:10.1038/s41591-022-02012-w · Cited by 220
Metadata
- Authors
- Brooke, S. M., An, H.-S., Kang, S.-K., Noble, J. M., Berg, K. E., & Lee, J.-M.
- Affiliations
- University of Nebraska at Omaha (US)
- Yong In University (KR)
- Corresponding author
- Lee, Jung-Min
- ORCID
- Lee, Jung-Min
- Venue
- Journal of Strength and Conditioning Research
- Published
- 2017-04
- Volume
- 31
- Issue
- 4
- Pages
- 1097-1106
- ISSN
- 1064-8011 (ISSN-L)
- OpenAlex
- W2502795088
- Cited by
- 79
- References
- 19
- Citations by year
- 2026: 3 · 2025: 4 · 2024: 4 · 2023: 4 · 2022: 11 · 2021: 14 · 2020: 15 · 2019: 8 · 2018: 10 · 2017: 5
- FWCI
- 6.17
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- The Journal of Strength and Conditioning Research (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Physical Activity and Health
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Health Professions › General Health Professions › Mobile Health and mHealth Applications
- Keywords
- wearable activity trackers, concurrent validity, energy expenditure estimation, free-living conditions, equivalence testing, mean absolute percentage error, physical activity monitoring, sleep monitoring
- MeSH terms
- Fitness Trackers, Adult, Energy Metabolism, Female, Humans, Male, Sleep, Reproducibility of Results, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review