Validity of the Elite HRV Smartphone Application for Examining Heart Rate Variability in a Field-Based Setting
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Perrotta, AS, Jeklin, AT, Hives, BA, Meanwell, LE, and Warburton, DER. Validity of the elite HRV smartphone application for examining heart rate variability in a field-based setting. J Strength Cond Res 31(8): 2296–2302, 2017—The introduction of smartphone applications has allowed athletes and practitioners to record and store R-R intervals on smartphones for immediate heart rate variability (HRV) analysis. This user-friendly option should be validated in the effort to provide practitioners confidence when monitoring their athletes before implementing such equipment. The objective of this investigation was to examine the relationship and validity between a vagal-related HRV index, rMSSD, when derived from a smartphone application accessible with most operating systems against a frequently used computer software program, Kubios HRV 2.2. R-R intervals were recorded immediately upon awakening over 14 consecutive days using the Elite HRV smartphone application. R-R recordings were then exported into Kubios HRV 2.2 for analysis. The relationship and levels of agreement between rMSSD ln derived from Elite HRV and Kubios HRV 2.2 was examined using a Pearson product-moment correlation and a Bland-Altman Plot. An extremely large relationship was identified (r = 0.92; p < 0.0001; confidence interval [CI] 95% = 0.90–0.93). A total of 6.4% of the residuals fell outside the 1.96 ± SD (CI 95% = −12.0 to 7.0%) limits of agreement. A negative bias was observed (mean: −2.7%; CI 95% = −3.10 to −2.30%), whose CI 95% failed to fall within the line of equality. Our observations demonstrated differences between the two sources of HRV analysis. However, further research is warranted, as this smartphone HRV application may offer a reliable platform when assessing parasympathetic modulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Heart Rate Variability: Standards of Measurement, Physiological Interpretation, and Clinical Use
Electrophysiology, T. F. O. T. E. S. O. C. T. N. A. (1996) · Circulation · doi:10.1161/01.cir.93.5.1043 · Cited by 17,159
Understanding bland altman analysis
Giavarina, D. (2015) · Biochemia Medica · doi:10.11613/bm.2015.015 · Cited by 4,706 · cited 1×
“However, when identifying new instruments for the purpose of replacing or interchangeable use, further statistical support beyond a strong correlation focusing on the limits of agreement should be implemented (2,9).”
BackgroundMeasures of Reliability in Sports Medicine and Science
Hopkins, W. G. (2000) · Sports Medicine · doi:10.2165/00007256-200030010-00001 · Cited by 4,635 · cited 1×
“However, the logarithmic transformation of the raw rMSSD values have been suggested to correct this nonuniformity of error whereby applying a similar magnitude of error for all values measured (11).”
MethodMonitoring training status with HR measures: do all roads lead to Rome?
Buchheit, M. (2014) · Frontiers in Physiology · doi:10.3389/fphys.2014.00073 · Cited by 879 · cited 4×
“Although this investigation solely examined the validity of a popular smartphone HRVapplication, recent reviews have postulated that the occurrence of reoccurring errors after automatic filtering should not prevent practitioners from effectively monitoring their athletes when this filtering method is standardized for…”
BackgroundInfluentialPlews, D. J., Laursen, P. B., Stanley, J., Kilding, A. E., & Buchheit, M. (2013) · Sports Medicine · doi:10.1007/s40279-013-0071-8 · Cited by 617
Penttilä, J., Helminen, A., Jartti, T., Kuusela, T., Huikuri, H. V., Tulppo, M. P., Coffeng, R., & Scheinin, H. (2001) · Clinical Physiology · doi:10.1046/j.1365-2281.2001.00337.x · Cited by 567 · cited 1×
“Previous investigations have identified rMSSD to possess robust statistical properties capable of negating significant influence toward R-R interval length from respiratory sinus arrhythmia when not controlling for breathing rate and depth (21).”
BackgroundCardiac Parasympathetic Reactivation Following Exercise: Implications for Training Prescription
Stanley, J., Peake, J. M., & Buchheit, M. (2013) · Sports Medicine · doi:10.1007/s40279-013-0083-4 · Cited by 529 · cited 2×
“Previous literature has demonstrated how practitioners can examine the magnitude of autonomic modulation through examining resting heart rate (HR) and the variability between beat-to-beat (R-R) intervals in response to a training stress (6,25), psychological stress (7,26), alterations in blood volume (5), and hormonal…”
BackgroundWarburton, D. E. R., Jamnik, V. K., Bredin, S. S. D., & Gledhill, N. (2011) · The Health & Fitness Journal of Canada · doi:10.14288/hfjc.v4i2.103 · Cited by 375
Self-citationValidity of the Polar V800 heart rate monitor to measure RR intervals at rest
Giles, D., Draper, N., & Neil, W. (2016) · European Journal of Applied Physiology · doi:10.1007/s00421-015-3303-9 · Cited by 373 · cited 1×
“Previous literature has demonstrated the use of a Polar H7 as a valid HR monitor when recording R-R intervals for HRV analysis (10).”
Method
Cited by
Schaffarczyk, M., Rogers, B., Reer, R., & Gronwald, T. (2022) · Sensors · doi:10.3390/s22176536 · Cited by 349
Schneider, C., Hanakam, F., Wiewelhove, T., Döweling, A., Kellmann, M., Meyer, T., Pfeiffer, M., & Ferrauti, A. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.00639 · Cited by 222
“Furthermore, the extended evaluation and application of ultra-short-term recordings (<5min, often ≤1min; Flatt and Esco, 2013; Esco and Flatt, 2014; Nakamura et al., 2015; Pereira et al., 2016; Esco et al., 2018) with commercial software, such as smartphone applications (e.g., Elite HRV Perrotta et al., 2017; ithlete…”
MethodMoya-Ramon, M., Mateo-March, M., Peña-González, I., Zabala, M., & Javaloyes, A. (2022) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2022.106696 · Cited by 122
Metadata
- Authors
- Perrotta, A. S., Jeklin, A. T., Hives, B. A., Meanwell, L. E., & Warburton, D. E. R.
- Venue
- Journal of Strength and Conditioning Research
- Published
- 2017-08
- Volume
- 31
- Issue
- 8
- Pages
- 2296-2302
- ISSN
- 1064-8011 (ISSN-L)
- OpenAlex
- W2587649185
- Cited by
- 179
- References
- 28
- FWCI
- 7.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validity of the Elite HRV Smartphone Application for Examining Heart Rate Variability in a Field-Based Setting. https://app.cochat.ai/papers/10.1519/jsc.0000000000001841
- The paper
- Perrotta, A. S., Jeklin, A. T., Hives, B. A., Meanwell, L. E., & Warburton, D. E. R. (2017). Validity of the Elite HRV Smartphone Application for Examining Heart Rate Variability in a Field-Based Setting. Journal of Strength and Conditioning Research. https://doi.org/10.1519/jsc.0000000000001841
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.