CoChat

Power Output and Electromyographic Activity During and After a Moderate Load Muscular Endurance Session

Smilios, Ilias, Häkkinen, Keijo, Tokmakidis, Savvas P · 2010 · Journal of Strength and Conditioning Research
Cited by 53

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

The purpose of this study was to examine (a) the mechanical power and the electromyographic (EMG) activity during a moderate load muscular endurance session and (b) the maximal mechanical power output and EMG activity using a light load and a heavy load afterward. Sixteen men (age: 20.7 +/- 1.1 years) performed 4 sets of 20 repetitions with an initial load of 50% of 1 repetition maximum (1RM), and 2 minutes of rest, in the squat exercise. Furthermore, the subjects performed 4 repetitions with loads of 40 and 80% of 1RM before, immediately after, and 30 minutes after the end of the session. Average power and EMG activity from vastus medialis (VM), vastus lateralis (VL), and rectus femoris (RF) were recorded during the concentric phase of the lift. Average power did not change during the first 2 sets, while it decreased (p < 0.05) during the third and the fourth set. Average quadriceps (AQ), VM, VL, and RF activity increased (p < 0.05) until the 11th repetition, approximately, during each set while it increased gradually from set to set. Maximal power and AQ, VM, and VL activity with the loads of 40 and 80% of 1RM were decreased (p < 0.05) after the session. Blood lactate reached 10.2 +/- 2.5 and 13.1 +/- 4.1 mmolxL after the second and the fourth set, respectively. It appears that during a muscular endurance session with submaximal power output, mechanical performance may gradually decrease, probably due to metabolic fatigue, while muscle electrical activity may increase. Following this type of a session, maximal power output and muscle activation with a light and especially with a heavy load are reduced.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1519/jsc.0b013e3181a5bc44

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 53

Metadata

Authors
Smilios, I., Häkkinen, K., & Tokmakidis, S. P.
Venue
Journal of Strength and Conditioning Research
Published
2010-08
Volume
24
Issue
8
Pages
2122-2131
ISSN
1064-8011 (ISSN-L)
OpenAlex
W2029797954
Cited by
53
References
5
FWCI
2.01
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Power Output and Electromyographic Activity During and After a Moderate Load Muscular Endurance Session. https://app.cochat.ai/papers/10.1519/jsc.0b013e3181a5bc44
The paper
Smilios, I., Häkkinen, K., & Tokmakidis, S. P. (2010). Power Output and Electromyographic Activity During and After a Moderate Load Muscular Endurance Session. Journal of Strength and Conditioning Research. https://doi.org/10.1519/jsc.0b013e3181a5bc44

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.