CoChat

Comparison of Two Bioelectrical Impedance Analysis Devices With Dual Energy X-ray Absorptiometry and Magnetic Resonance Imaging in the Estimation of Body Composition

Wang, Ji-Guang, Zhang, Yi, Chen, Han-E, Li, Yan, Cheng, Xiao-Guang, Xu, Li, Guo, Zhe, Zhao, Xing-Shan, Sato, Tetsuya, Cao, Qi-Yun, Chen, Ke-Min, Li, Biao · 2013 · Journal of Strength and Conditioning Research
Cited by 127

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

We compared a 4-limb bioelectrical impedance analysis (BIA) system, HBF 359 (Omron), and a 2-limb foot-to-foot device, BC 532 (Tanita), with the standard dual energy X-ray absorptiometry (DXA) and magnetic resonance imaging (MRI) methods for the measurement of body fat percentage (BF), skeletal muscle mass percentage (SMM, or fat-free mass [FFM] for BC 532), and visceral fat level (VF). Body composition was measured in 200 healthy volunteers (100 men and 100 women, mean age 48 years) by HBF 359 and BC 532 and by DXA and MRI. The agreement was assessed by correlation analysis and paired t-test. The correlation coefficients between BIA and DXA or MRI ranged from 0.71 to 0.89 for BF, SMM, and VF by HBF 359 and from 0.77 to 0.90 for BF, FFM, and VF by BC 532 in all subjects and in men and women separately (p < 0.001 for all). Compared with DXA, HBF 359 significantly (p < 0.001) underestimated BF by -5.8% in men and -9.6% in women. Compared with MRI, the corresponding underestimatons (negative) or overestimations (positive) by HBF 359 in men and women were, respectively, +1.9% (p = 0.02) and +1.7% (p = 0.10) for SMM, and +13.3% (p < 0.001) and -8.5% (p = 0.006), for VF. The corresponding values by BC 532 in men and women were -10.7 and -6.2% for BF, -1.4 and -2.5% for FFM, and +20.4 and -18.0% for VF. The BIA devices are accurate in the estimation of body composition, especially skeletal muscle mass or FFM.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1519/jsc.0b013e31824f2040

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 127

Metadata

Authors
Wang, J.-G., Zhang, Y., Chen, H.-E., Li, Y., Cheng, X.-G., Xu, L., Guo, Z., Zhao, X.-S., Sato, T., Cao, Q.-Y., Chen, K.-M., & Li, B.
Venue
Journal of Strength and Conditioning Research
Published
2013-01
Volume
27
Issue
1
Pages
236-243
ISSN
1064-8011 (ISSN-L)
OpenAlex
W2040964051
Cited by
127
References
8
FWCI
3.59
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of Two Bioelectrical Impedance Analysis Devices With Dual Energy X-ray Absorptiometry and Magnetic Resonance Imaging in the Estimation of Body Composition. https://app.cochat.ai/papers/10.1519/jsc.0b013e31824f2040
The paper
Wang, J.-G., Zhang, Y., Chen, H.-E., Li, Y., Cheng, X.-G., Xu, L., Guo, Z., Zhao, X.-S., Sato, T., Cao, Q.-Y., Chen, K.-M., & Li, B. (2013). Comparison of Two Bioelectrical Impedance Analysis Devices With Dual Energy X-ray Absorptiometry and Magnetic Resonance Imaging in the Estimation of Body Composition. Journal of Strength and Conditioning Research. https://doi.org/10.1519/jsc.0b013e31824f2040

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.