Why Do Axons Differ in Caliber?
Open accessThe DOI matches its Crossref record; 82 of the 82 references it cites were found in a registry or an index.
Abstract
CNS axons differ in diameter (d) by nearly 100-fold (∼0.1–10 μm); therefore, they differ in cross-sectional area (d2) and volume by nearly 10,000-fold. If, as found for optic nerve, mitochondrial volume fraction is constant with axon diameter, energy capacity would rise with axon volume, also as d2. We asked, given constraints on space and energy, what functional requirements set an axon's diameter? Surveying 16 fiber groups spanning nearly the full range of diameters in five species (guinea pig, rat, monkey, locust, octopus), we found the following: (1) thin axons are most numerous; (2) mean firing frequencies, estimated for nine of the identified axon classes, are low for thin fibers and high for thick ones, ranging from ∼1 to >100 Hz; (3) a tract's distribution of fiber diameters, whether narrow or broad, and whether symmetric or skewed, reflects heterogeneity of information rates conveyed by its individual fibers; and (4) mitochondrial volume/axon length rises ≥d2. To explain the pressure toward thin diameters, we note an established law of diminishing returns: an axon, to double its information rate, must more than double its firing rate. Since diameter is apparently linear with firing rate, doubling information rate would more than quadruple an axon's volume and energy use. Thicker axons may be needed to encode features that cannot be efficiently decoded if their information is spread over several low-rate channels. Thus, information rate may be the main variable that sets axon caliber, with axons constrained to deliver information at the lowest acceptable rate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Mathematical Theory of Communication
Shannon, C. E. (1948) · Bell System Technical Journal · doi:10.1002/j.1538-7305.1948.tb00917.x · Cited by 48,949
(1982) · Trends in Neurosciences · doi:10.1016/0166-2236(82)90076-5 · Cited by 9,089
An Energy Budget for Signaling in the Grey Matter of the Brain
Attwell, D., & Laughlin, S. B. (2001) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200110000-00001 · Cited by 3,543 · cited 2×
“However, the energetic cost of one of its synaptic vesicles is only 0.1% of the cost of a spike (Attwell and Laughlin, 2001).”
BackgroundInfluentialCerebellar Cortex: Cytology and Organization
Palay, S. L., & Chan‐Palay, V. (1974) · Medical Entomology and Zoology · Cited by 1,679
(1991) · Medical Entomology and Zoology · Cited by 1,512
Palay, S. L., & Chan-Palay, V. (1974) · Springer eBooks · doi:10.1007/978-3-642-65581-4 · Cited by 1,506
Energy limitation as a selective pressure on the evolution of sensory systems
Niven, J. E., & Laughlin, S. B. (2008) · Journal of Experimental Biology · doi:10.1242/jeb.017574 · Cited by 1,056 · cited 1×
“This apparently constrains optic axons to fire at the lowest rates acceptable to their downstream targets (Niven and Laughlin, 2008).”
BackgroundSelf-citationVestibular System: The Many Facets of a Multimodal Sense
Angelaki, D. E., & Cullen, K. E. (2008) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.31.060407.125555 · Cited by 960
RELATIONS BETWEEN STRUCTURE AND FUNCTION IN THE DESIGN OF SKELETAL MUSCLES
Henneman, E., & Olson, C. B. (1965) · Journal of Neurophysiology · doi:10.1152/jn.1965.28.3.581 · Cited by 763
Efficient coding of natural sounds
Lewicki, M. S. (2002) · Nature Neuroscience · doi:10.1038/nn831 · Cited by 674
Cited by
Investigating white matter fibre density and morphology using fixel-based analysis.
Raffelt, D. A., Tournier, J.-D., Smith, R. E., Vaughan, D. N., Jackson, G., Ridgway, G. R., & Connelly, A. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.09.029 · Cited by 620
“Voxel-based analysis (VBA) of diffusion MRI is a common method for studying white matter, providing evidence of altered brain connectivity by detecting differences at a local level (Buchsbaum et al., 1998).”
Oligodendroglial NMDA receptors regulate glucose import and axonal energy metabolism
Saab, A. S., Tzvetavona, I. D., Trevisiol, A., Baltan, S., Dibaj, P., Kusch, K., Möbius, W., Goetze, B., Jahn, H. M., Huang, W., et al. (2016) · Neuron · doi:10.1016/j.neuron.2016.05.016 · Cited by 590
“126 Neuron 91, 119–132, July 6, 2016 The majority of myelinated axons in cortico-spinal tracts fire at a high frequency and comprise a high energy demanding white matter tract (Perge et al., 2012).”
InfluentialSterling, P., & Laughlin, S. (2015) · doi:10.7551/mitpress/9780262028707.001.0001 · Cited by 482
Self-citationLifespan maturation and degeneration of human brain white matter
Yeatman, J. D., Wandell, B. A., & Mezer, A. A. (2014) · Nature Communications · doi:10.1038/ncomms5932 · Cited by 432
Liewald, D., Miller, R., Logothetis, N., Wagner, H.-J., & Schüz, A. (2014) · Biological Cybernetics · doi:10.1007/s00422-014-0626-2 · Cited by 322
“Other important aspects of axon calibre and/or myelination have been pointed out in the seminal papers by Wang et al. (2008) and Perge et al. (2009, 2012), such as the relation to energy consumption, firing rate, information rate or size of terminal arbours.”
Critical pathogenic events underlying progression of neurodegeneration in glaucoma
Calkins, D. J. (2012) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2012.07.001 · Cited by 309
Scaling and systems biology for integrating multiple organs-on-a-chip
Wikswo, J. P., Curtis, E. L., Eagleton, Z. E., Evans, B. C., Kole, A., Hofmeister, L. H., & Matloff, W. J. (2013) · Lab on a Chip · doi:10.1039/c3lc50243k · Cited by 309
Kita, T., & Kita, H. (2012) · The Journal of Neuroscience · doi:10.1523/jneurosci.5717-11.2012 · Cited by 275
The Axon-Myelin Unit in Development and Degenerative Disease
Stassart, R. M., Möbius, W., Nave, K.-A., & Edgar, J. M. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00467 · Cited by 246
On Myelinated Axon Plasticity and Neuronal Circuit Formation and Function
Almeida, R. G., & Lyons, D. A. (2017) · The Journal of Neuroscience · doi:10.1523/jneurosci.3185-16.2017 · Cited by 221
“In addition to regulating the speed and timing of conduction, myelinated axons may also better sustain high-frequency firing compared with unmyelinated axons (Perge et al., 2012).”
BackgroundLutz, P.-E., Tanti, A., Gasecka, A., Barnett-Burns, S., Kim, J. J., Zhou, Y., Chen, G. G., Wakid, M., Shaw, M., Almeida, D., et al. (2017) · American Journal of Psychiatry · doi:10.1176/appi.ajp.2017.16111286 · Cited by 203
Dense neuronal reconstruction through X-ray holographic nano-tomography
Kuan, A. T., Phelps, J. S., Thomas, L. A., Nguyen, T. M., Han, J., Chen, C.-L., Azevedo, A. W., Tuthill, J. C., Funke, J., Cloetens, P., et al. (2020) · Nature Neuroscience · doi:10.1038/s41593-020-0704-9 · Cited by 160
“In doing so, we found systematic variation in the axon diameter of different sensory neuron types, suggesting that some types of sensory signals (namely those from coxal hair plates and trochanteral campaniform sensilla) are conducted to the VNC faster 36 or more reliably 37 than others (Fig.”
Balasubramanian, V. (2021) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2107022118 · Cited by 113
Self-citationThe neurobiology of interoception and affect
Feldman, M. J., Bliss-Moreau, E., & Lindquist, K. A. (2024) · Trends in Cognitive Sciences · doi:10.1016/j.tics.2024.01.009 · Cited by 101
“In contrast, thicker fi bers are less metabolically ef fi cient but can convey more information per unit of time and are less susceptible to channel noise [72,73].”
Age-related changes in the visual pathways: blame it on the axon
Calkins, D. J. (2013) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.13-12784 · Cited by 96
“7 lm in diameter), approximately half as thick the cone photoreceptor axon despite being 50-fold longer.(24) While optimized for minimal firing rate and energy use,(25,26) the small size of RGC axons has implications for susceptibility over time to lightinduced damage, metabolic stress, disruption of Ca2þ homeostasis,…”
BackgroundScaling of sensorimotor delays in terrestrial mammals
More, H. L., & Donelan, J. M. (2018) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2018.0613 · Cited by 88
Estimating axon conduction velocity in vivo from microstructural MRI
Drakesmith, M., Harms, R., Rudrapatna, S. U., Parker, G. D., Evans, C. J., & Jones, D. K. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.116186 · Cited by 83
Theriault (n.d.) · doi:10.31234/osf.io/pkzr8 · Cited by 51
Nakahira, Y., Liu, Q., Sejnowski, T. J., & Doyle, J. C. (2021) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1916367118 · Cited by 49
Applying microstructural models to understand the role of white matter in cognitive development
Huber, E., Henriques, R. N., Owen, J. P., Rokem, A., & Yeatman, J. D. (2019) · Developmental Cognitive Neuroscience · doi:10.1016/j.dcn.2019.100624 · Cited by 34
Basu, K., Appukuttan, S., Manchanda, R., & Sik, A. (2023) · Cerebral Cortex · doi:10.1093/cercor/bhac329 · Cited by 29
Tahayori, B., Meffin, H., Sergeev, E. N., Mareels, I. M. Y., Burkitt, A. N., & Grayden, D. B. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/6/065005 · Cited by 24
Metadata
- Authors
- Perge, J. A., Niven, J. E., Mugnaini, E., Balasubramanian, V., & Sterling, P.
- Venue
- The Journal of Neuroscience
- Publisher
- Society for Neuroscience
- Published
- 2012-01-11
- Volume
- 32
- Issue
- 2
- Pages
- 626-638
- ISSN
- 0270-6474 (ISSN-L)
- 1529-2401
- OpenAlex
- W2079111057
- Cited by
- 326
- References
- 82
- FWCI
- 6.13
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.