High-Resolution Electrical Stimulation of Primate Retina for Epiretinal Implant Design
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
The development of retinal implants for the blind depends crucially on understanding how neurons in the retina respond to electrical stimulation. This study used multielectrode arrays to stimulate ganglion cells in the peripheral macaque retina, which is very similar to the human retina. Analysis was restricted to parasol cells, which form one of the major high-resolution visual pathways in primates. Individual cells were characterized using visual stimuli, and subsequently targeted for electrical stimulation using electrodes 9–15 μm in diameter. Results were accumulated across 16 ON and 9 OFF parasol cells. At threshold, all cells responded to biphasic electrical pulses 0.05–0.1 ms in duration by firing a single spike with latency lower than 0.35 ms. The average threshold charge density was 0.050 ± 0.005 mC/cm 2, significantly below established safety limits for platinum electrodes. ON and OFF ganglion cells were stimulated with similar efficacy. Repetitive stimulation elicited spikes within a 0.1 ms time window, indicating that the high temporal precision necessary for spike-by-spike stimulation can be achieved in primate retina. Spatial analysis of observed thresholds suggests that electrical activation occurred near the axon hillock, and that dendrites contributed little. Finally, stimulation of a single parasol cell produced little or no activation of other cells in the ON and OFF parasol cell mosaics. The low-threshold, temporally precise, and spatially specific responses hold promise for the application of high-density arrays of small electrodes in epiretinal implants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
How parallel are the primate visual pathways?
Merigan, W. H., & Maunsell, J. H. R. (1993) · Annual Review of Neuroscience · doi:10.1146/annurev.ne.16.030193.002101 · Cited by 1,597 · cited 2×
“…work focuses on ON and OFF parasol cells, which together constitute the second most dense visual pathway in the primate retina (Rodieck, 1998; Dacey, 2004) and form the dominant projection to the magnocellular layers of the lateral geniculate nucleus (Van Essen, 1985; Merigan and Maunsell, 1993).”
BackgroundRetinal remodeling triggered by photoreceptor degenerations
Jones, B. W., Watt, C. B., Frederick, J. M., Baehr, W., Chen, C., Levine, E. M., Milam, A. H., Lavail, M. M., & Marc, R. E. (2003) · Journal of Comparative Neurology · doi:10.1002/cne.10703 · Cited by 476 · cited 2×
“cell number by neuronal death has been reported, along with occasional formation of neurite fascicles containing ganglion cell dendrites, and rare eversion of somas to the distal retina (Jones et al., 2003).”
BackgroundWeiland, J. D., Liu, W., & Humayun, M. S. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.060804.100435 · Cited by 371
Jensen, R. J., Ziv, O. R., & Rizzo, J. F. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-1018 · Cited by 159 · cited 1×
“Several recent studies have reported short-latency spikes, followed by long-latency responses (Jensen et al., 2005; Fried et al., 2006; Sekirnjak et al., 2006).”
BackgroundJensen, R. J., Rizzo, J. F., Ziv, O. R., Grumet, A., & Wyatt, J. (2003) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.02-1041 · Cited by 145
Cited by
Functional architecture of the retina: Development and disease
Hoon, M., Okawa, H., Della Santina, L., & Wong, R. O. L. (2014) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2014.06.003 · Cited by 585
Photovoltaic retinal prosthesis with high pixel density
Mathieson, K., Loudin, J., Goetz, G., Huie, P., Wang, L., Kamins, T. I., Galambos, L., Smith, R., Harris, J. S., Sher, A., et al. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.104 · Cited by 467
Self-citationThe Argus® II Retinal Prosthesis System
Luo, Y. H.-L., & da Cruz, L. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2015.09.003 · Cited by 351
Retinal stimulation strategies to restore vision: fundamentals and systems
Yue, L., Weiland, J. D., Roska, B., & Humayun, M. S. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2016.05.002 · Cited by 272
Retinal prosthetic strategy with the capacity to restore normal vision
Nirenberg, S., & Pandarinath, C. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1207035109 · Cited by 207
Metadata
- Authors
- Sekirnjak, C., Hottowy, P., Sher, A., Dabrowski, W., Litke, A. M., & Chichilnisky, E. J.
- Venue
- The Journal of Neuroscience
- Publisher
- Society for Neuroscience
- Published
- 2008-04-23
- Volume
- 28
- Issue
- 17
- Pages
- 4446-4456
- ISSN
- 0270-6474 (ISSN-L)
- 1529-2401
- OpenAlex
- W1978023046
- Cited by
- 194
- References
- 5
- FWCI
- 4.53
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.