Thresholds for Activation of Rabbit Retinal Ganglion Cells with Relatively Large, Extracellular Microelectrodes

Jensen, Ralph J., Ziv, Ofer R., Rizzo, Joseph F.·2005·Investigative Opthalmology & Visual Science

Abstract

PURPOSE: To investigate the responses of retinal ganglion cells (RGCs) to electrical stimulation, using electrodes comparable in size to those used in human studies investigating the feasibility of an electronic retinal prosthesis. METHODS: Rabbit retinas were stimulated in vitro with current pulses applied to the inner surface with 125- and 500-mum diameter electrodes while the responses of RGCs were recorded extracellularly. RESULTS: Both short-latency (SL; 3-5 ms) and long-latency (LL; >/=9 ms) responses were observed after electrical stimulation within the receptive field of an RGC. With short, 0.1-ms current pulses, the threshold current for the SL cell response was significantly lower than that for the LL cell response. With long (10- to 20-ms) pulses, the threshold currents for the SL and LL cell responses were very similar. The threshold current for the SL cell response increased more steeply than did the LL cell response when the electrode was displaced from the point of lowest electrical threshold, either above or along the surface of the retina. Stimulation of an RGC axon outside of the cell's receptive field produced only an SL response. For 0.1-ms duration pulses, the threshold current for the axonal response was significantly higher than the threshold current for the SL cell response. At pulse durations > 1 ms, the thresholds were very similar. CONCLUSIONS: RGC responses to electrical stimulation depend on the current pulse duration and location of the stimulating electrode. For an epiretinal prosthesis, short-duration current pulses may be preferable since they result in a more localized activation of the retina.

Integrity signals

Registry

Crossref · 10.1167/iovs.04-1018

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Jensen, R. J., Ziv, O. R., & Rizzo, J. F.
Affiliations
  • VA Boston Healthcare System (US)
  • Massachusetts Eye and Ear Infirmary (US)
Venue
Investigative Opthalmology & Visual Science
Published
2005-04-01
Volume
46
Issue
4
Pages
1486
ISSN
  • 0146-0404 (ISSN-L)
  • 1552-5783
OpenAlex
W2005579016
Cited by
159
References
32
Citations by year
2026: 2 · 2025: 3 · 2024: 5 · 2023: 1 · 2022: 7 · 2021: 8 · 2020: 12 · 2019: 5 · 2018: 7 · 2017: 6 · 2016: 3 · 2015: 8 · 2014: 9 · 2013: 12 · 2012: 7
FWCI
3.98
Type
journal article
Language
en
Open access
closed
Locations
  • Investigative Ophthalmology & Visual Science (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Retinal Development and Disorders
  • Health Sciences › Medicine › Anesthesiology and Pain Medicine › Pain Management and Treatment
Keywords
retinal ganglion cells, electrical stimulation, stimulation threshold, epiretinal prosthesis, pulse duration, short-latency responses, long-latency responses, receptive fields, rabbit retina
MeSH terms
Animals, Electric Conductivity, Electric Stimulation, Electrophysiology, Microelectrodes, Rabbits, Retinal Ganglion Cells, Sensory Thresholds

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review