The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Hand Movement Direction Decoded from MEG and EEG
Open accessAbstract
Brain activity can be used as a control signal for brain–machine interfaces (BMIs). A powerful and widely acknowledged BMI approach, so far only applied in invasive recording techniques, uses neuronal signals related to limb movements for equivalent, multidimensional control of an external effector. Here, we investigated whether this approach is also applicable for noninvasive recording techniques. To this end, we recorded whole-head MEG during center-out movements with the hand and found significant power modulation of MEG activity between rest and movement in three frequency bands: an increase for ≤7 Hz (low-frequency band) and 62–87 Hz (high-γ band) and a decrease for 10–30 Hz (β band) during movement. Movement directions could be inferred on a single-trial basis from the low-pass filtered MEG activity as well as from power modulations in the low-frequency band, but not from the β and high-γ bands. Using sensors above the motor area, we obtained a surprisingly high decoding accuracy of 67% on average across subjects. Decoding accuracy started to rise significantly above chance level before movement onset. Based on simultaneous MEG and EEG recordings, we show that the inference of movement direction works equally well for both recording techniques. In summary, our results show that neuronal activity associated with different movements of the same effector can be distinguished by means of noninvasive recordings and might, thus, be used to drive a noninvasive BMI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Learning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761 · cited 2×
“In invasive BMI research, a different approach has been successful: the spiking activity of cortical cells related to movements of one limb is used for equivalent control of an external effector (Serruya et al., 2002; Taylor et al., 2002; Carmena et al., 2003; Hochberg et al., 2006).”
BackgroundMethodA spelling device for the paralysed
Birbaumer, N., Ghanayim, N., Hinterberger, T., Iversen, I., Kotchoubey, B., Kübler, A., Perelmouter, J., Taub, E., & Flor, H. (1999) · Nature · doi:10.1038/18581 · Cited by 1,577
Self-citationA new look at habits and the habit-goal interface.
Wood, W., & Neal, D. T. (2007) · Psychological Review · doi:10.1037/0033-295x.114.4.843 · Cited by 1,470
An efficient P300-based brain–computer interface for disabled subjects
Hoffmann, U., Vesin, J.-M., Ebrahimi, T., & Diserens, K. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.03.005 · Cited by 859
Coherent neural representation of hand speed in humans revealed by MEG imaging
Jerbi, K., Lachaux, J.-P., N′Diaye, K., Pantazis, D., Leahy, R. M., Garnero, L., & Baillet, S. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0609632104 · Cited by 289
Vidaurre, C., Schloogl, A., Cabeza, R., Scherer, R., & Pfurtscheller, G. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.873542 · Cited by 195
Cited by
Beta-band oscillations—Signalling the status quo?
Engel, A. K., & Fries, P. (2010) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2010.02.015 · Cited by 2,953
Review of the BCI Competition IV
Tangermann, M., Müller, K.-R., Aertsen, A., Birbaumer, N., Braun, C., Brunner, C., Leeb, R., Mehring, C., Miller, K. J., Müller-Putz, G. R., et al. (2012) · Frontiers in Neuroscience · doi:10.3389/fnins.2012.00055 · Cited by 1,288
Self-citationInter-Brain Synchronization during Social Interaction
Dumas, G., Nadel, J., Soussignan, R., Martinerie, J., & Garnero, L. (2010) · PLoS ONE · doi:10.1371/journal.pone.0012166 · Cited by 966
Enhanced performance by a hybrid NIRS–EEG brain computer interface
Fazli, S., Mehnert, J., Steinbrink, J., Curio, G., Villringer, A., Müller, K.-R., & Blankertz, B. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.07.084 · Cited by 599
Combrisson, E., & Jerbi, K. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.01.010 · Cited by 599
Metadata
- Authors
- Waldert, S., Preissl, H., Demandt, E., Braun, C., Birbaumer, N., Aertsen, A., & Mehring, C.
- Venue
- The Journal of Neuroscience
- Publisher
- Society for Neuroscience
- Published
- 2008-01-23
- Volume
- 28
- Issue
- 4
- Pages
- 1000-1008
- ISSN
- 0270-6474 (ISSN-L)
- 1529-2401
- OpenAlex
- W2159619227
- Cited by
- 415
- References
- 7
- FWCI
- 16.88
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hand Movement Direction Decoded from MEG and EEG. https://app.cochat.ai/papers/10.1523/jneurosci.5171-07.2008
- The paper
- Waldert, S., Preissl, H., Demandt, E., Braun, C., Birbaumer, N., Aertsen, A., & Mehring, C. (2008). Hand Movement Direction Decoded from MEG and EEG. The Journal of Neuroscience. https://doi.org/10.1523/jneurosci.5171-07.2008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.