The DOI matches its Crossref record; 67 of the 68 references it cites were found in a registry or an index.
Theoretical Evaluation of Voltage Inducement on Internal Membranes of Biological Cells Exposed to Electric Fields
Open accessAbstract
Several reports have recently been published on effects of very short and intense electric pulses on cellular organelles; in a number of cases, the cell plasma membrane appeared to be affected less than certain organelle membranes, whereas with longer and less intense pulses the opposite is the case. The effects are the consequence of the voltages induced on the membranes, and in this article we investigate the conditions under which the induced voltage on an organelle membrane could exceed its counterpart on the cell membrane. This would provide a possible explanation of the observed effects of very short pulses. Frequency-domain analysis yields an insight into the dependence of the voltage inducement on the electric and geometric parameters characterizing the cell and its vicinity. We show that at sufficiently high field frequencies, for a range of parameter values the voltage induced on the organelle membrane can indeed exceed the voltage induced on the cell membrane. Particularly, this can occur if the organelle interior is electrically more conductive than the cytosol, or if the organelle membrane has a lower dielectric permittivity than the cell membrane, and we discuss the plausibility of these conditions. Time-domain analysis is then used to determine the courses of the voltage induced on the membranes by pulses with risetimes and durations in the nanosecond range. The particularly high resting voltage in mitochondria, to which the induced voltage superimposes, could contribute to the explanation why these organelles are the primary target of many observed effects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“as the frequency of the field increases, the high membrane field gain diminishes, allowing for higher field intensities to penetrate into the cell.”
From An Overview of Sub-Cellular Mechanisms Involved in the Action of TTFields (2016) · cites this paper as [31]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Methods of Theoretical Physics
Morse, P. M., Feshbach, H., & Hill, E. L. (1954) · American Journal of Physics · doi:10.1119/1.1933765 · Cited by 13,197
Lodish, H. F. (1986) · Cited by 5,650
Methods of theoretical physics
Domenicali, C. A. (1954) · Journal of the Franklin Institute · doi:10.1016/0016-0032(54)90634-1 · Cited by 4,893
Mathematical Methods for Physicists
Arfken, G. B., & Mathews, J. (1972) · American Journal of Physics · doi:10.1119/1.1988084 · Cited by 4,069
Fröhlich, H., & Maradudin, A. A. (1949) · CERN Document Server (European Organization for Nuclear Research) · Cited by 2,213
Gautier, J. (1993) · Trends in Biochemical Sciences · doi:10.1016/0968-0004(93)90025-i · Cited by 2,200
Theory of electroporation: A review
Weaver, J. C., & Chizmadzhev, Y. A. (1996) · Bioelectrochemistry and Bioenergetics · doi:10.1016/s0302-4598(96)05062-3 · Cited by 1,639
Mathematical Methods for Physicists
(1995) · Elsevier eBooks · doi:10.1016/c2009-1-28537-6 · Cited by 1,255
Electroporation and Electrofusion in Cell Biology
Neumann, E., Sowers, A. E., & Jordan, C. A. (1989) · Springer eBooks · doi:10.1007/978-1-4899-2528-2 · Cited by 947
Oberhettinger, F., & Badii, L. (1973) · Springer eBooks · doi:10.1007/978-3-642-65645-3 · Cited by 762
Flagged first, then by citations
1 of the 68 references couldn’t be matched to a known paper.
Cited by
Sorted by citations
Items 201–300 of 318
Applicative Use of Electroporation Models
Rems, L. (2017) · Advances in biomembranes and lipid self-assembly · doi:10.1016/bs.abl.2017.06.001 · Cited by 5
Induced-charge electro-osmosis in dielectric annuli
Feng, H., & Wong, T. N. (2018) · Applied Mathematics and Computation · doi:10.1016/j.amc.2018.03.106 · Cited by 5
The Effect of KcsA Channel on Lipid Bilayer Electroporation Induced by Picosecond Pulse Trains
Tang, J., Ma, J., Guo, L., Wang, K., Yang, Y., Bo, W., Yang, L., Jiang, H., Wu, Z., Zeng, B., et al. (2020) · The Journal of Membrane Biology · doi:10.1007/s00232-020-00123-4 · Cited by 5
A 3-D Multiphysics Modeling of Electroporation Excited by a Single Pulse
Hao, X.-Z., Xie, Y., Guo, J. J., & Xie, W.-C. (2023) · IEEE Transactions on Dielectrics and Electrical Insulation · doi:10.1109/tdei.2023.3244770 · Cited by 5
“ness on the Non-Uniformity Factor: Although Table I shows typical values of the electrical and geometric parameters of the cell, variation ranges of these parameters that are physically realistic, or at least plausible values for different cells [13], must be taken into consideration.”
BackgroundMethodArena, C. B., Neal, R. E., & Davalos, R. V. (2014) · Elsevier eBooks · doi:10.1016/b978-0-444-53632-7.01016-9 · Cited by 5
Analysis for relationship of transmembrane potential–pulsed electric field frequency
Jiahui, L., Xinlao, W., Yonghong, W., & Gongqiang, L. (2008) · Food and Bioproducts Processing · doi:10.1016/j.fbp.2008.10.003 · Cited by 5
Evaluation of Induced Voltage on Biological Cell Membranes
Campbell, R. M., Crichton, B. H., Fouracre, R. A., Timoshkin, I. V., & Given, M. J. (2006) · IEEE International Power Modulator Symposium and High-Voltage Workshop (IPMHVC) · doi:10.1109/modsym.2006.365294 · Cited by 5
Iuliis, G. N. D., Newey, R. J., King, B. V., & Aitken, R. J. (2013) · PLoS ONE · doi:10.1371/annotation/9a8a0172-3850-4059-b852-72c330769c1b · Cited by 5
Liang, C., Ai, F., Wang, P., Kang, J., Deng, H. P., Fan, Z., Lin, Z., Liu, G., Zhu, Y., & Tao, J. (2025) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2025.149207 · Cited by 4
Resolving nanosecond kinetics of the optical membrane potential in pulsed electric fields
Semenov, I., Šilkūnienė, G., Šilkūnas, M., Pakhomova, O. N., Bixler, J. N., Ibey, B. L., Keppler, M. A., & Pakhomov, A. G. (2025) · Bioelectrochemistry · doi:10.1016/j.bioelechem.2025.109143 · Cited by 4
Beyond Electroporation Pulse Parameters: From Application to Evaluation
Reberšek, M. (2017) · Springer eBooks · doi:10.1007/978-3-319-32886-7_222 · Cited by 4
Bonnafont, T., Bessières, D., & Paillol, J. (2024) · Journal of Computational Physics · doi:10.1016/j.jcp.2024.112862 · Cited by 4
Ron, A., Fishelson, N., Croitoru, N. I., Shur, I., Benayahu, D., & Shacham‐Diamand, Y. (2009) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2009.10.020 · Cited by 4
Zheng, Y., Gao, Y., Chen, R., Wang, H., Dong, L., & Dou, J.-R. (2016) · Bioelectromagnetics · doi:10.1002/bem.21993 · Cited by 4
Application of the Taguchi method to explore a robust condition of tumor-treating field treatment
Kurata, K., Shimada, K., & Takamatsu, H. (2022) · PLoS ONE · doi:10.1371/journal.pone.0262133 · Cited by 4
Yano, K.-I., Rems, L., Kotnik, T., Miklavčič, D., Weaver, J. C., Smith, K. C., Son, R. S., Gowrishankar, T. R., Vernier, P. T., Levine, Z. A., et al. (2016) · Springer eBooks · doi:10.1007/978-4-431-56095-1_4 · Cited by 4
Measurement and Characterization of Exposure Systems for High-Frequency, Ultrashort Pulses
Lévêque, P., O'Connor, R. P., & Arnaud‐Cormos, D. (2017) · Springer eBooks · doi:10.1007/978-3-319-32886-7_207 · Cited by 4
Kumar, M., & Mishra, A. (2024) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/ad33a9 · Cited by 3
A Many-Shells Model for Cell Transmembrane Potentials for Pulsed Electric Field Applications
Wong, T., Timoshkin, I. V., MacGregor, S. J., Wilson, M. P., Given, M. J., & Maclean, M. (2024) · IEEE Transactions on Plasma Science · doi:10.1109/tps.2024.3395761 · Cited by 4
“Comparison of inner and outer TMPs developed across a spherical cell with data from [31], [36] with the present many-shells model with n = 5.”
BackgroundMethodAtomistic Simulations of Electroporation of Model Cell Membranes
Tarek, M. (2017) · Advances in anatomy, embryology and cell biology · doi:10.1007/978-3-319-56895-9_1 · Cited by 4
Tissue Ablation Using Nanosecond Electric Pulses
Nuccitelli, R. (2017) · Springer eBooks · doi:10.1007/978-3-319-32886-7_93 · Cited by 4
Modulating Apoptosis in Cancer Therapy with Ultrasound and High-Intensity Nanosecond Electric Pulses
Yu, T., Wu, M., Huang, P. C., & Hu, L. (2013) · Springer eBooks · doi:10.1007/978-94-007-6211-4_22 · Cited by 4
Finite Element Modeling of in Vivo Electroporation
Pavšelj, N., & Damijan Miklavčič, A. (2009) · Series in biomedical engineering · doi:10.1007/978-3-642-05420-4_7 · Cited by 4
“Even further, if we are using nanopulses, cell organelles must be added to the geometry (Kotnik and Miklavcic, 2006).”
BackgroundInfluence of Extracellular Environment on Electroporation Efficiency
Bazzolo, B., Conconi, M. T., Dettin, M., Zamuner, A., Campana, L. G., & Sieni, E. (2020) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-030-64610-3_75 · Cited by 3
Jerbic, K., Svejda, J. T., Sievert, B., Rennings, A., Fröhlich, J., & Erni, D. (2023) · Bioelectromagnetics · doi:10.1002/bem.22436 · Cited by 3
“…analytical studies using such cell models have been successfully employed to investigate the distribution of EM fields in the cell interior, allowing the approximate determination of induced membrane voltages and losses [Kotnik and Miklavčič, 2000, 2006; Vajrala et al., 2008; Ye et al., 2010].”
MethodThe estimation of pore size distribution of electroporated MCF-7 cell membrane
Eşmekaya, M. A., Gürsoy, G., & Coşkun, A. (2024) · Electromagnetic Biology and Medicine · doi:10.1080/15368378.2024.2366272 · Cited by 3
“Because the external electric field is amplified by the membrane (Kotnik and Miklavcic 2006).”
Yin, M., Xiao, J., Huang, G., Xie, H., Liu, H., Yuan, J., Liu, X., Chiarini, A., Armato, U., Prà, I. D., et al. (2025) · Regenerative Therapy · doi:10.1016/j.reth.2025.06.004 · Cited by 3
Electro-Impulse Irreversible Plant Tissue Damage as Highly Efficient Agricultural Technology
Yudaev, I. V., Daus, Y. V., Kokurin, R., Prokofyev, P. V., Валерьевна, Г. В., & Armenyanov, N. (2019) · Advances in environmental engineering and green technologies book series · doi:10.4018/978-1-5225-7573-3.ch015 · Cited by 3
Infrared Laser-Based Single Cell Permeabilization by Plasma Membrane Temperature Gradients
Garner, A. L., Neculaes, V. B., & Dylov, D. V. (2022) · Membranes · doi:10.3390/membranes12060574 · Cited by 3
“45 GHz microwave field induced membrane permeabilization to green fluorescent protein (GFP) with negligible temperature increase in the surrounding medium [26]; calculations of the transmembrane potential using common techniques [27,28] readily show that these fields cannot induce transmembrane potential remotely near…”
BackgroundMethodUçak, İ., Afreen, M., Benova, E., Marinova, P., Bogdanov, T. G., Turtoi, M., Pătraşcu, L., & Aprodu, I. (2022) · Food engineering series · doi:10.1007/978-3-030-92415-7_4 · Cited by 3
Design of Electrical Characterization Method for Electroporation-Treated Biological Tissues
Lamberti, P., Sieni, E., & Sundararajan, R. (2023) · Designs · doi:10.3390/designs7020035 · Cited by 3
Khan, M. S., Agazar, M., & Bihan, Y. L. (2023) · Energies · doi:10.3390/en17010166 · Cited by 3
Schoenbach, K. H., Neumann, E., Heller, R. F., Vernier, P. T., Teissié, J., & Beebe, S. J. (2016) · Springer eBooks · doi:10.1007/978-4-431-56095-1_1 · Cited by 3
Electromagnetic Radiation and Oxidative Stress in the Male Germ Line
Iuliis, G. N. D., King, B. V., & Aitken, R. J. (2012) · Humana Press eBooks · doi:10.1007/978-1-61779-776-7_1 · Cited by 3
Li, C., Hu, L.-N., Dong, X., Sun, C.-X., & Miz, Y. (2008) · International Journal of Gynecological Cancer · doi:10.1111/j.1525-1438.2007.01182.x · Cited by 3
Kohler, S., Ho, M.-C., Levine, Z. A., Vernier, P. T., Lévêque, P., & Arnaud‐Cormos, D. (2014) · IEEE MTT-S International Microwave Symposium digest · doi:10.1109/mwsym.2014.6848464 · Cited by 3
“microdosimetric studies have also suggested that nsPEFs can induce large differential voltages across the cell's inner membranes [3-5].”
BackgroundThe effect of dielectric relaxation in nanosecond pulse electroporation of biological cells
Salimi, E., Bridges, G. E., & Thomson, D. J. (2010) · International Symposium on Antenna Technology and Applied Electromagnetics · doi:10.1109/antem.2010.5552521 · Cited by 3
Using Bode Plots to Access Intracellular Coupling
Gerber, H. L., Joshi, R. P., & Tseng, C. C. (2008) · IEEE Transactions on Plasma Science · doi:10.1109/tps.2008.2001042 · Cited by 3
Measurement and Characterization of Exposure Systems for High-Frequency, Ultrashort Pulses
Lévêque, P., O'Connor, R. P., & Arnaud‐Cormos, D. (2017) · Springer eBooks · doi:10.1007/978-3-319-26779-1_207-1 · Cited by 3
Ninagawa, Y., Sugiura, R., Kato, E., Yagi, I., Nagata, K., Yamaoka, H., Tachibana, K., Oda, A., & Uchida, S. (2025) · Electrical Engineering in Japan · doi:10.1002/eej.23493 · Cited by 2
“…, µ m 94.7 Cell membrane relative permittivity 11.7 [17] Cell membrane conductivity, S/m 1.1 × 10 − 7 [17] Cytoplasm relative permittivity 67 [17, 18, 20, 21] Cytoplasm conductivity, S/m 0.32 [17, 18, 20, 21] Nuclear envelope relative permittivity 70.6 [19] Nuclear envelope conductivity, S/m…”
InfluentialFilho, C. M. M., & Silva, E. K. (2026) · Trends in Food Science & Technology · doi:10.1016/j.tifs.2026.105842 · Cited by 2
Lee, P. S., Sriperumbudur, K. K., Dawson, J. E., van Rienen, U., & Appali, R. (2024) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ad9530 · Cited by 2
“The cells were modelled as multiple concentric shells [75, 76] to determine the induced EF in the internal membranes of the cells.”
Local Joule heating and electric force on biological membrane during electro-microinjection
Wang, S., & Shirakashi, R. (2019) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2019.06.010 · Cited by 2
Tiwari, P. K. (2015) · Japanese Journal of Applied Physics · doi:10.7567/jjap.54.097301 · Cited by 2
Dynamics and control of the two-pulse protocol in electroporation: Numerical exploration
Jiang, W., & Zhao, X. (2011) · Mathematical Biosciences · doi:10.1016/j.mbs.2011.03.013 · Cited by 2
“Many models of electroporation have been developed by various authors [35, 20, 14, 30, 24, 16].”
BackgroundProving lightning role in the evolution of life
Liberti, M., Apollonio, F., Merla, C., & d'Inzeo, G. (2013) · Physics of Life Reviews · doi:10.1016/j.plrev.2013.07.026 · Cited by 2
Denzi, A., Merla, C., André, F. M., García-Sánchez, T., Mir, L. M., Apollonio, F., & Liberti, M. (2018) · IEEE MTT-S International Microwave Biomedical Conference (IMBioC) · doi:10.1109/imbioc.2018.8428949 · Cited by 2
Niven, C. G., Parker, C. B., Wolter, S. D., Dryzer, M. H., Arena, C. B., Stoner, B. R., & Ngaboyamahina, E. (2020) · Journal of Water Sanitation and Hygiene for Development · doi:10.2166/washdev.2020.192 · Cited by 2
Transmembrane Voltage Induced by Applied Electric Fields
Kotnik, T. (2017) · Springer eBooks · doi:10.1007/978-3-319-32886-7_8 · Cited by 2
Possible Effects of Electric Fields on a Pair of Spherical Cells
Zheng, Y., Xue, J., Gao, Y., Dong, L., Dou, J.-R., & Ma, W. (2017) · The Journal of Membrane Biology · doi:10.1007/s00232-017-9967-9 · Cited by 2
Beebe, S. J. (2021) · Series in bioengineering · doi:10.1007/978-981-10-5113-5_8 · Cited by 1
Sieni, E., Nemec, S., Lamberti, P., Romeo, S., Sgarbossa, P., Forzan, M., Golzio, M., Rols, M., Kolosnjaj‐Tabi, J., & Kralj, S. (2023) · IEEE Nanotechnology Materials and Devices Conference (NMDC) · doi:10.1109/nmdc57951.2023.10344060 · Cited by 1
Models of Irreversible Electroporation: A Review and Initial Model Implementation
Georgiev, T., Bliznakova, K. S., Bliznakov, Z. B., & Todorov, G. (2024) · TEM Journal · doi:10.18421/tem131-54 · Cited by 1
Rumyantseva, A. A., Borde, A. S., Ordzhonikidze, M., Izmaylov, A., Pokidysheva, L., Samorodov, A. V., Shchukin, S. I., & Volkov, A. K. (2025) · Journal of Electrostatics · doi:10.1016/j.elstat.2025.104063 · Cited by 1
Numerical evaluation of transmembrane potential in cell aggregates in presence of lipid droplets
Forzan, M., Barba, P. D., Mognaschi, M. E., Golzio, M., Rols, M., Kolosnjaj‐Tabi, J., & Sieni, E. (2025) · International Journal of Applied Electromagnetics and Mechanics · doi:10.1177/13835416251332847 · Cited by 1
Research Progress on the Application of Irreversible Electroporation Ablation in Cancers
Zhang, R., Xie, L., Jin, Q., Zhang, C., Guo, T., Zhao, Q., & Jiang, T. (2025) · Advanced ultrasound in diagnosis and therapy · doi:10.26599/audt.2025.240052 · Cited by 1
Simulation study of Escherichia coli electroporation induced by pulsed magnetic field
Guo, F., Yuan, H. R., & Dan, G. (2026) · Journal of Food Engineering · doi:10.1016/j.jfoodeng.2026.113013 · Cited by 1
Kumar, R., Kumar, M., Chakrabarti, R., & Thaokar, R. (2026) · Biophysical Journal · doi:10.1016/j.bpj.2026.04.009 · Cited by 1
Zou, S., Wang, J., Xue, N., Xu, W., Xu, J., Gao, D., & Guan, S. (2026) · Polymer · doi:10.1016/j.polymer.2026.130146 · Cited by 1
Wu, M. (2012) · AFRICAN JOURNAL OF BIOTECHNOLOGY · doi:10.5897/ajbx11.040 · Cited by 1
“In Kotnik and Miklavcic (2006), both dielectric permittivity and electric conductivity of the organelles were considered but only plasma membrane and organelle membrane are taken into account for explaining why the voltage induced on the organelle membrane can exceed the voltage induced on plasma…”
BackgroundInfluentialDependence of transmembrane voltage on pulsed electric field frequency
Li, J., Wei, X., Xu, X., & Wang, Y. (2009) · International Conference on Properties and Applications of Dielectric Materials (ICPADM) · doi:10.1109/icpadm.2009.5252283 · Cited by 1
“* 2 j f σ σ π ε = + under time-varying electric field[4].”
Biophysical Effects of Tumor Treating Fields
Wenger, C., & Miranda, P. C. (2016) · Springer eBooks · doi:10.1007/978-3-319-30576-9_3 · Cited by 1
ELECTROCHEMICAL LYSIS IN ONCOLOGY: LITERATURE REVIEW
Аниканова, Е. В., Guens, G. P., Kolontarev, K. B., & Александрович, М. С. (2021) · Siberian Journal of Oncology · doi:10.21294/1814-4861-2021-20-3-124-133 · Cited by 1
Kumar, M., Kumar, S., Chakrabartty, S., Poulose, A., Mostafa, H., & Goyal, B. (2023) · Micromachines · doi:10.3390/mi14122136 · Cited by 1
Cell Electroporation Model Using Voronoi Networks
Hu, Q., & Joshi, R. P. (2016) · Springer eBooks · doi:10.1007/978-3-319-26779-1_141-1 · Cited by 1
Effects of usEPs on Plasma Membranes—Pores, Channels, and Repair
Beebe, S. J. (2021) · Series in bioengineering · doi:10.1007/978-981-10-5113-5_2 · Cited by 1
Simulations of Membrane Effects of Cells After Exposure to Ultrashort Pulses
Joshi, R. P. (2021) · Series in bioengineering · doi:10.1007/978-981-10-5113-5_3 · Cited by 1
Numerical studies on the effect of electric pulses on an egg-shaped cell with a spherical nucleus
Buret, F., Faure, N., Nicolas, L., Perrussel, R., & Poignard, C. (2010) · HAL · Cited by 1
Pulse electric field exposure effect on morphological properties of HeLa cells
Adon, M. N. (2015) · UTHM Institutional Repository (Universiti Tun Hussein Onn Malaysia) · Cited by 1
Ivey, J. W. (2017) · VTechWorks (Virginia Tech) · Cited by 1
Measuring dielectric properties of biological cells as a function of temperature
Vadlamani, A., Zhuang, J., Kolb, J. F., & Garner, A. L. (2014) · IEEE International Power Modulator Symposium and High-Voltage Workshop (IPMHVC) · doi:10.1109/ipmhvc.2014.7287295
Plasma Membrane Charging of Jurkat Cells by Nanosecond Pulsed Electric Fields
Kolb, J. F., White, J. A., Pliquett, U. F., Nuccitelli, R., Schoenbach, K. H., Beebe, S. J., Joshi, R. P., & Frey, W. (2007) · IEEE International Conference on Plasma Science (ICOPS) · doi:10.1109/ppps.2007.4345783
Exposure of cells to electric fields: Numerical analysis with a volume-integral-equation approach
Acosta, J. C. V., Lancellotti, V., & Zwamborn, A. P. M. (2014) · European Conference on Antennas and Propagation · doi:10.1109/eucap.2014.6902506
“A fair approximation to the shape of a biological cell is a spherical double-shell of outer radius a [9].”
BackgroundMethodInfluentialCytochrome c release caused by Pulsed Electric Fields (PEFs) with different time durations
Wu, H., Wu, M., & Zou, H. (2012) · International Workshop on Microwave and Millimeter Wave Circuits and System Technology · doi:10.1109/mmwcst.2012.6238126
Numerical investigation of proximity effects on field gradients in biological cells
Acosta, J. C. V., Lancellotti, V., & Zwamborn, A. P. M. (2014) · European Conference on Antennas and Propagation · doi:10.1109/eucap.2014.6902107
“3 [7] 3 [F/m] 5 0 [7] σ3 [S/m] 3x10−7 [7] 4 [F/m] 72 0 [7] σ4 [S/m] 1.”
BackgroundMethodInfluentialLow Voltage Pulse Application to Biological Cells
Otsuka, H., Okimura, S., Nagamura, M., Matsukuma, D., Kutsuzawa, K., Matsuda, N., & OKABE, H. (2013) · IEICE Transactions on Electronics · doi:10.1587/transele.e96.c.348
Microdosimetry for ultrashort electric pulses: A literature review
Merla, C., Paffi, A., Apollonio, F., & Liberti, M. (2012) · European Conference on Antennas and Propagation · doi:10.1109/eucap.2012.6206626
Rems, L., Pucihar, G., & Damijan Miklavčič, A. (2011) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-642-23508-5_67
Intraorganelle Nanoporation in Biomedical Application
Sarkar, S., & Mk, G. (2015) · International Journal of Computer Applications · doi:10.5120/20764-3195
Advancements in Irreversible Electroporation for the Treatment of Cancer
Arena, C. B. (2013) · VTechWorks (Virginia Tech)
Ye, H., & Curcuru, A. N. (2016) · Journal of Biomedical Engineering and Informatics · doi:10.5430/jbei.v3n1p18
Oddziaływanie pola elektromagnetycznego na proces hiperaktywacji nasienia - badanie pilotażowe
Wdowiak, A. (2017) · PRZEGLĄD ELEKTROTECHNICZNY · doi:10.15199/48.2017.01.54
Latouche, E. L. (2016) · VTechWorks (Virginia Tech)
Cancelation Effect of Nanosecond Pulse Electric Fields on Cells In Vitro
Ibey, B. L. (2018) · Springer eBooks · doi:10.1007/978-3-319-26779-1_144-1
Therapeutic and Side Effects Modeling of Electrolytic Cancer Ablation Therapy Using Organ-on-a-Chip
Park, M. C., Yoo, J. M., & Kim, A. (2019) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/transducers.2019.8808803
Computational microdosimetry at cellular level at millimeter wave frequencies
Haider, Z., Dréan, Y. L., Sauleau, R., & Zhadobov, M. (2020) · IEEE MTT-S International Microwave Biomedical Conference (IMBioC) · doi:10.1109/imbioc47321.2020.9384902
“The analytical methods are based on the solution of quasi-static Laplace equation for spherical, spheroidal and ellipsoidal cells [5-8].”
MethodThe Frequency Dependent Response of Sinewave Electropermeabilization
García-Sánchez, T., Angelis, A. D., Apollonio, F., Liberti, M., Mir, L. M., & Merla, C. (2020) · IEEE MTT-S International Microwave Biomedical Conference (IMBioC) · doi:10.1109/imbioc47321.2020.9385025
“Although theoretically described [6], few experimental reports have deeply studied the ability of AC signals to cause cell permeabilization as in [7].”
BackgroundResultSimulation of single cell electroporation
Liu, Q., & Yang, L. (2021) · E3S Web of Conferences · doi:10.1051/e3sconf/202127101033
usEP Effects on the Endoplasmic Reticulum (ER)
Beebe, S. J. (2021) · Series in bioengineering · doi:10.1007/978-981-10-5113-5_5
Oughstun, K. E. (2019) · Springer series in optical sciences/SPringer series in optical sciences · doi:10.1007/978-3-030-20692-5_8
Oughstun, K. E. (2009) · Springer series in optical sciences/SPringer series in optical sciences · doi:10.1007/978-1-4419-0149-1_9
Napotnik, T. B., Rebersek, M., Kotnik, T., Lebrasseur, É., Cabodevila, G., & Miklavčič, D. (2011) · SpringerReference · doi:10.1007/springerreference_66686
Cell Electroporation Model Using Voronoi Networks
Hu, Q., & Joshi, R. P. (2017) · Springer eBooks · doi:10.1007/978-3-319-32886-7_141
(2023) · Elsevier eBooks · doi:10.1016/b978-0-12-819107-1.16001-7
Brosseau, C. (2023) · Studies in mechanobiology, tissue engineering and biomaterials · doi:10.1007/978-3-031-37981-9_5
Application of Electric Fields to Reduce Microorganism Contamination for Animal-Based Products
Yudhistira, B., Husnayain, N., & Punthi, F. (2023) · Jurnal Teknologi Hasil Pertanian · doi:10.20961/jthp.v16i2.78423
“Its value varies depending on the kind of cell and normally falls between 80 and 40 mV (Kotnik & Miklavčič, 2006).”
Background
Metadata
- Authors
- Kotnik, T., & Miklavčič, D.
- Affiliations
- University of Ljubljana (SI)
- Corresponding author
- Kotnik, Tadej
- ORCID
- Kotnik, Tadej
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 2006-01
- Volume
- 90
- Issue
- 2
- Pages
- 480-491
- ISSN
- 0006-3495 (ISSN-L)
- PMC
- PMC1367054
- OpenAlex
- W2106955112
- Cited by
- 318
- References
- 68
- Citations by year
- 2026: 13 · 2025: 11 · 2024: 15 · 2023: 22 · 2022: 12 · 2021: 12 · 2020: 17 · 2019: 20 · 2018: 19 · 2017: 26 · 2016: 19 · 2015: 12 · 2014: 19 · 2013: 17 · 2012: 17
- FWCI
- 4.26
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Biophysical Journal (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Electromagnetic Fields and Biological Effects
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biotechnology › Microbial Inactivation Methods
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrical and Electromagnetic Research
- Keywords
- electric field effects on cells, organelle membranes, nanosecond pulses, frequency domain analysis, time-domain analysis, membrane conductivity
- MeSH terms
- Animals, Biological Transport, Active, Biophysics, Cell Membrane, Cell Membrane Permeability, Cytosol, Electric Conductivity, Electromagnetic Fields, Intracellular Membranes, Membrane Fluidity, Membrane Lipids, Membrane Potentials, Models, Theoretical, Time Factors
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review