Quantitative Scattering of Melanin Solutions
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The optical scattering coefficient of a dilute, well-solubilized eumelanin solution has been accurately measured as a function of incident wavelength, and found to contribute <6% of the total optical attenuation between 210 and 325 nm. At longer wavelengths (325-800 nm), the scattering was less than the minimum sensitivity of our instrument. This indicates that ultraviolet and visible optical density spectra can be interpreted as true absorption with a high degree of confidence. The scattering coefficient versus wavelength was found to be consistent with Rayleigh theory for a particle radius of 38 +/- 1 nm. Our results shed important light on the role of melanins as photoprotectants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Classical Electrodynamics, 3rd ed .
Jackson, J. D., & Fox, R. F. (1999) · American Journal of Physics · doi:10.1119/1.19136 · Cited by 3,073
Chemical and Structural Disorder in Eumelanins: A Possible Explanation for Broadband Absorbance
Tran, M. L., Powell, B. J., & Meredith, P. (2006) · Biophysical Journal · doi:10.1529/biophysj.105.069096 · Cited by 286
Self-citation
Cited by
Liu, Y., Ai, K., & Lu, L. (2014) · Chemical Reviews · doi:10.1021/cr400407a · Cited by 4,794
The physical and chemical properties of eumelanin
Meredith, P., & Sarna, T. (2006) · Pigment Cell Research · doi:10.1111/j.1600-0749.2006.00345.x · Cited by 1,033
Self-citationSurface Modification of Water Purification Membranes
Miller, D. J., Dreyer, D. R., Bielawski, C. W., Paul, D. R., & Freeman, B. D. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201601509 · Cited by 747
Dopamine−Melanin Film Deposition Depends on the Used Oxidant and Buffer Solution
Bernsmann, F., Ball, V., Addiego, F., Ponche, A., Michel, M., Gracio, J. J. D. A., Toniazzo, V., & Ruch, D. (2011) · Langmuir · doi:10.1021/la104981s · Cited by 544
Melanins and melanogenesis: Methods, standards, protocols
d'Ischia, M., Wakamatsu, K., Napolitano, A., Briganti, S., Garcia‐Borron, J., Kovacs, D., Meredith, P., Pezzella, A., Picardo, M., Sarna, T., et al. (2013) · Pigment Cell & Melanoma Research · doi:10.1111/pcmr.12121 · Cited by 484
Self-citationThe supramolecular structure of melanin
Watt, A. A. R., Bothma, J. P., & Meredith, P. (2009) · Soft Matter · doi:10.1039/b902507c · Cited by 308
Self-citationYu, X., Fan, H., Liu, Y., Shi, Z., & Jin, Z. (2014) · Langmuir · doi:10.1021/la500225v · Cited by 257
Zonios, G., Dimou, A., Bassukas, I., Galaris, D., Tsolakidis, A., & Kaxiras, E. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2844710 · Cited by 246
“29 The structure of melanin may also be affected in vivo by interactions with melanosome proteins.”
BackgroundWavelength-dependent penetration depths of ultraviolet radiation in human skin
Meinhardt, M., Krebs, R., Anders, A., Heinrich, U., & Tronnier, H. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2957970 · Cited by 210
“Melanin also acts as a scatterer, but its scattering coefficient only contributes a few percent of the total attenuation coefficient in the UV.(19) Thus, the thenar absorption spectrum is dominated by the characteristics of keratin, whose absorption coefficient is rapidly decreasing toward longer wavelengths.”
BackgroundInfluentialDadachova, E., Bryan, R. A., Howell, R. C., Schweitzer, A. D., Aisen, P., Nosanchuk, J. D., & Casadevall, A. (2008) · Pigment Cell & Melanoma Research · doi:10.1111/j.1755-148x.2007.00430.x · Cited by 182
“While the scattering of nonionizing electromagnetic radiation by melanin can be described by the application of Mie and Rayleigh scattering algorithms for calculation of scattering coefficients for a multilayered sphere (Bhandari, 1985; Riesz et al., 2006), ionizing radiation interacts with melanin to produce profound…”
BackgroundMelanin pigments of fungi under extreme environmental conditions (Review)
Gessler, N. N., Egorova, A. S., & Belozerskaya, T. A. (2014) · Applied Biochemistry and Microbiology · doi:10.1134/s0003683814020094 · Cited by 176
Pezzella, A., Iadonisi, A., Valerio, S., Panzella, L., Napolitano, A., Adinolfi, M., & d’Ischia, M. (2009) · Journal of the American Chemical Society · doi:10.1021/ja905162s · Cited by 147
Jonasson, H., Fredriksson, I., Bergstrand, S., Östgren, C. J., Larsson, M., & Strömberg, T. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.23.12.121608 · Cited by 52
Ascione, L., Pezzella, A., Ambrogi, V., Carfagna, C., & d'Ischia, M. (2013) · Photochemistry and Photobiology · doi:10.1111/php.12003 · Cited by 31
Metadata
- Authors
- Riesz, J., Gilmore, J., & Meredith, P.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 2006-06
- Volume
- 90
- Issue
- 11
- Pages
- 4137-4144
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W2038113411
- Cited by
- 102
- References
- 2
- FWCI
- 2.00
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.