Resonant Waveguide Grating Biosensor for Living Cell Sensing
Open accessThe DOI matches its Crossref record; 52 of the 52 references it cites were found in a registry or an index.
Abstract
This article presents theoretical analysis and experimental data for the use of resonant waveguide grating (RWG) biosensors to characterize stimulation-mediated cell responses including signaling. The biosensor is capable of detecting redistribution of cellular contents in both directions that are perpendicular and parallel to the sensor surface. This capability relies on online monitoring cell responses with multiple optical output parameters, including the changes in incident angle and the shape of the resonant peaks. Although the changes in peak shape are mainly contributed to stimulation-modulated inhomogeneous redistribution of cellular contents parallel to the sensor surface, the shift in incident angle primarily reflects the stimulation-triggered dynamic mass redistribution (DMR) perpendicular to the sensor surface. The optical signatures are obtained and used to characterize several cellular processes including cell adhesion and spreading, detachment and signaling by trypsinization, and signaling through either epidermal growth factor receptor or bradykinin B2 receptor. A mathematical model is developed to link the bradykinin-mediated DMR signals to the dynamic relocation of intracellular proteins and the receptor internalization during B2 receptor signaling cycle. This model takes the form of a set of nonlinear, ordinary differential equations that describe the changes in four different states of B2 receptors, diffusion of proteins and receptor-protein complexes, and the DMR responses. Classical analysis shows that the system converges to a unique optical signature, whose dynamics (amplitudes, transition time, and kinetics) is dependent on the bradykinin signal input, and consistent with those observed using the RWG biosensors. This study provides fundamentals for probing living cells with the RWG biosensors, in general, optical biosensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Focal Adhesions: Transmembrane Junctions Between the Extracellular Matrix and the Cytoskeleton
Burridge, K., Fath, K., Kelly, T., Nuckolls, G., & Turner, C. (1988) · Annual Review of Cell Biology · doi:10.1146/annurev.cb.04.110188.002415 · Cited by 2,120
Prenzel, N., Zwick, E., Daub, H., Leserer, M., Abraham, R., Wallasch, C., & Ullrich, A. (1999) · Nature · doi:10.1038/47260 · Cited by 1,504
Proteinase-activated Receptors
(2006) · Encyclopedic Reference of Molecular Pharmacology · doi:10.1007/3-540-29832-0_1335 · Cited by 1,137
Optical biosensors in drug discovery
Cooper, M. A. (2002) · Nature Reviews Drug Discovery · doi:10.1038/nrd838 · Cited by 1,015
Leeb-Lundberg, L. M. F., Marceau, F., Müller-Esterl, W., Pettibone, D. J., & Zuraw, B. L. (2005) · Pharmacological Reviews · doi:10.1124/pr.57.1.2 · Cited by 943
Hu, C.-D., & Kerppola, T. K. (2003) · Nature Biotechnology · doi:10.1038/nbt816 · Cited by 781
Proteinase-Activated Receptors
Macfarlane, S. R., Seatter, M. J., Kanke, T., Hunter, G. D., & Plevin, R. (2001) · Pharmacological Reviews · doi:10.1016/s0031-6997(24)01493-5 · Cited by 641
Sensitivity of grating couplers as integrated-optical chemical sensors
Tiefenthaler, K., & Lukosz, W. (1989) · Journal of the Optical Society of America B · doi:10.1364/josab.6.000209 · Cited by 620
Integrated optics and new wave phenomena in optical waveguides
Tien, P. K. (1977) · Reviews of Modern Physics · doi:10.1103/revmodphys.49.361 · Cited by 565
Vicente-Manzanares, M., Webb, D. J., & Horwitz, A. R. (2005) · Journal of Cell Science · doi:10.1242/jcs.02662 · Cited by 380
Cited by
Whispering-gallery-mode biosensing: label-free detection down to single molecules
Vollmer, F., & Arnold, S. (2008) · Nature Methods · doi:10.1038/nmeth.1221 · Cited by 1,660
Kenakin, T., & Miller, L. J. (2010) · Pharmacological Reviews · doi:10.1124/pr.108.000992 · Cited by 573
Functional Selectivity and Biased Receptor Signaling
Kenakin, T. (2011) · The Journal of Pharmacology and Experimental Therapeutics · doi:10.1124/jpet.110.173948 · Cited by 505
Survey of the year 2003 commercial optical biosensor literature
Rich, R. L., & Myszka, D. G. (2005) · Journal of Molecular Recognition · doi:10.1002/jmr.726 · Cited by 505
Lack of beta-arrestin signaling in the absence of active G proteins
Grundmann, M., Merten, N., Malfacini, D., Inoue, A., Preis, P., Simon, K., Rüttiger, N., Ziegler, N., Benkel, T., Schmitt, N. K., et al. (2018) · Nature Communications · doi:10.1038/s41467-017-02661-3 · Cited by 358
Schröder, R., Janssen, N., Schmidt, J., Kebig, A., Merten, N., Hennen, S., Müller, A., Blättermann, S., Mohr-Andrä, M., Zahn, S., et al. (2010) · Nature Biotechnology · doi:10.1038/nbt.1671 · Cited by 256
Dynamic and Label-Free Cell-Based Assays Using the Real-Time Cell Electronic Sensing System
Atienza, J. M., Yu, N., Kirstein, S. L., Xi, B., Wang, X., Xu, X., & Abassi, Y. A. (2006) · ASSAY and Drug Development Technologies · doi:10.1089/adt.2006.4.597 · Cited by 178
“39 Real-time monitoring and the preclusion of labeling reagents using the RT-CES system provide succinct information regarding the strength of cell attachment and spreading and the kinetics involved in this process.”
Schröder, R., Schmidt, J., Blättermann, S., Peters, L., Janssen, N., Grundmann, M., Seemann, W., Kaufel, D., Merten, N., Drewke, C., et al. (2011) · Nature Protocols · doi:10.1038/nprot.2011.386 · Cited by 173
Antibiotic-induced release of small extracellular vesicles (exosomes) with surface-associated DNA
Németh, A., Orgovan, N., Sódar, B. W., Osteikoetxea, X., Pálóczi, K., Szabó-Taylor, K. É., Vukman, K. V., Kittel, Á., Turiák, L., Wiener, Z., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-08392-1 · Cited by 146
Organs-on-chip monitoring: sensors and other strategies
Kilic, T., Navaee, F., Stradolini, F., Renaud, P., & Carrara, S. (2018) · Microphysiological Systems · doi:10.21037/mps.2018.01.01 · Cited by 96
“So far, sensors for the purpose of monitoring cellular adhesion (49), detachment (50), death (51), response to osmotic stress (52), sepsis (53) have been developed based on widely used surface plasmon resonance (SPR) technique, photonic crystal fibers (54), and resonant waveguide grating EPIC systems (55).”
MethodPatko, D., Mártonfalvi, Z., Kovacs, B., Vonderviszt, F., Kellermayer, M., & Horvath, R. (2014) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2014.01.107 · Cited by 74
Metadata
- Authors
- Fang, Y., Ferrie, A. M., Fontaine, N. H., Mauro, J., & Balakrishnan, J.
- Venue
- Biophysical Journal
- Publisher
- Elsevier BV
- Published
- 2006-09
- Volume
- 91
- Issue
- 5
- Pages
- 1925-1940
- ISSN
- 0006-3495 (ISSN-L)
- OpenAlex
- W2062866488
- Cited by
- 383
- References
- 52
- FWCI
- 7.67
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.