CoChat

Measurements of plasma metanephrines by immunoassay vs liquid chromatography with tandem mass spectrometry for diagnosis of pheochromocytoma

Weismann, Dirk, Peitzsch, Mirko, Raida, Anna, Prejbisz, Aleksander, Gosk, Maria, Riester, Anna, Willenberg, Holger S, Klemm, Reiner, Manz, Georg, Deutschbein, Timo, Kroiss, Matthias, Därr, Roland, Bidlingmaier, Martin, Januszewicz, Andrzej, Eisenhofer, Graeme, Fassnacht, Martin · 2015 · European Journal of Endocrinology
Cited by 64

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Background: Reports conflict concerning measurements of plasma metanephrines (MNs) for diagnosis of pheochromocytomas/paragangliomas (PPGLs) by immunoassays compared with other methods. We aimed to compare the performance of a commercially available enzyme-linked immunoassay (EIA) kit with liquid chromatography–tandem mass spectrometric (LC–MS/MS) measurements of MNs to diagnose PPGLs. Methods: In a substudy of a prospective, multicenter trial to study the biochemical profiles of monoamine-producing tumors, we included 341 patients (174 males and 167 females) with suspected PPGLs (median age 54 years), of whom 54 had confirmed PPGLs. Plasma MNs were measured by EIA and LC–MS/MS, each in a specialized laboratory. Results: Plasma normetanephrine (NMN) and MN were measured 60 and 39% lower by EIA than by LC–MS/MS. Using upper cut-offs stipulated for the EIA, diagnostic sensitivity was only 74.1% at a specificity of 99.3%. In contrast, use of similar cut-offs for MN and overall lower age-adjusted cut-offs for NMN measured by LC–MS/MS returned a diagnostic sensitivity and specificity of 98.1 and 99.7%. Areas under receiver-operating characteristic curves, nevertheless, indicated comparable diagnostic performance of the EIA (0.993) and LC–MS/MS (0.985). Diagnostic sensitivity for the EIA increased to 96.2% with a minimal loss in specificity (95.1%) following use of cut-offs for the EIA adapted to correct for the negative bias. Conclusions: The EIA underestimates plasma MNs and diagnostic sensitivity is poor using commonly stipulated cut-offs, resulting in a high risk for missing patients with PPGLs. Correction of this shortcoming can be achieved by appropriately determined cut-offs resulting in comparable diagnostic performance of EIA and LC–MS/MS assays.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1530/eje-14-0730

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 64

Metadata

Authors
Weismann, D., Peitzsch, M., Raida, A., Prejbisz, A., Gosk, M., Riester, A., Willenberg, H. S., Klemm, R., Manz, G., Deutschbein, T., Kroiss, M., Därr, R., Bidlingmaier, M., Januszewicz, A., Eisenhofer, G., & Fassnacht, M.
Venue
European Journal of Endocrinology
Published
2015-03
Volume
172
Issue
3
Pages
251-260
ISSN
  • 0804-4643 (ISSN-L)
  • 1479-683X
OpenAlex
W2165922371
Cited by
64
References
3
FWCI
3.88
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Measurements of plasma metanephrines by immunoassay vs liquid chromatography with tandem mass spectrometry for diagnosis of pheochromocytoma. https://app.cochat.ai/papers/10.1530/eje-14-0730
The paper
Weismann, D., Peitzsch, M., Raida, A., Prejbisz, A., Gosk, M., Riester, A., Willenberg, H. S., Klemm, R., Manz, G., Deutschbein, T., Kroiss, M., Därr, R., Bidlingmaier, M., Januszewicz, A., Eisenhofer, G., & Fassnacht, M. (2015). Measurements of plasma metanephrines by immunoassay vs liquid chromatography with tandem mass spectrometry for diagnosis of pheochromocytoma. European Journal of Endocrinology. https://doi.org/10.1530/eje-14-0730

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.