Real-Time Continuous Glucose Monitoring in Pediatric Patients During and After Cardiac Surgery

Piper, Hannah G., Alexander, Jamin L., Shukla, Avinash, Pigula, Frank, Costello, John M., Laussen, Peter C., Jaksic, Tom, Agus, Michael S.D. · 2006 · Pediatrics
Cited by 137

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

OBJECTIVES. Given the demonstrated benefit of euglycemia in critically ill patients as well as the risk for hypoglycemia during insulin infusion in children, we sought to validate a subcutaneous sensor for real-time continuous glucose monitoring in pediatric patients during and after cardiac surgery. METHODS. Children up to 36 months of age who were undergoing cardiac bypass surgery were recruited. After anesthetic induction, a continuous glucose-monitoring system sensor (CGMS, Medtronic Minimed, Northridge, CA) was inserted subcutaneously. Sensors remained in place for up to 72 hours. Arterial blood glucose was measured intermittently in the central laboratory (Bayer Rapidlab 860, Tarrytown, NY). Sensor data, after prospective calibration with 6-hourly laboratory values using the proprietary Medtronic Minimed Guardian RT algorithm, were compared with all laboratory glucose values. Statistical analysis was performed to test whether sensor performance was affected by body temperature, inotrope dose, or body-wall edema. RESULTS. Twenty patients were enrolled in the study for a total of 40 study days and 246 paired sensor and laboratory glucose values. Consensus error grid analysis demonstrated that 72.0% of sensor value comparisons were within zone A (no effect on clinical action), and 27.6% of comparisons were within zone B (altered clinical action of little or no effect on outcome), with a mean absolute relative deviation of 17.6% for all comparisons. One comparison (0.4%) was in zone C (altered clinical action likely to affect outcome). No significant correlations were found between sensor performance and body temperature, inotrope dose, or body-wall edema. All patients tolerated the sensors well without bleeding or tissue reaction. CONCLUSIONS. Guardian RT real-time subcutaneous blood glucose measurement is safe and potentially useful for continuous glucose monitoring in critically ill children. Subcutaneous sensors performed well in the setting of hypothermia, inotrope use, and edema. These sensors facilitate identifying and following the effects of interventions to control blood glucose.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1542/peds.2006-0347

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Piper, H. G., Alexander, J. L., Shukla, A., Pigula, F., Costello, J. M., Laussen, P. C., Jaksic, T., & Agus, M. S. D.
Venue
Pediatrics
Published
2006-09-01
Volume
118
Issue
3
Pages
1176-1184
ISSN
  • 0031-4005 (ISSN-L)
  • 1098-4275
OpenAlex
W2029237990
Cited by
137
References
3
FWCI
5.65
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.