Transient grating spectroscopy: An ultrarapid, nondestructive materials evaluation technique
Open accessThe claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
TGS enables in situ measurements during irradiation, unlike traditional ex situ approaches such as nanoindentation, X-ray diffraction, or TEM.
“Unlike traditional ex situ approaches-such as nanoindentation, X-ray diffraction, or TEM-that cannot easily operate in extreme irradiation environments, TGS enables in situ measurements.”
From A facility for thermo-mechanical characterization of fusion magnet materials during cryogenic ion irradiation (2025) · cites this paper as [8]
In “Probing material evolution via elastic properties” (page unavailable), the paper describes TGS measurements made during ion-beam irradiation and contrasts them with slower traditional post-irradiation examination. It does not establish that all three named methods cannot easily operate during irradiation; it also cites in situ TEM observations. The comparison with those specific methods is therefore broader than the source supports. (LLM, conf=0.84)
Experimental — accuracy not yet measuredTGS is a non-contact method for characterizing changes in elastic, acoustic, and thermal transport properties, making it a powerful tool for inferring material structure evolution.
“TGS is a non-contact method for characterizing changes in elastic, acoustic, and thermal transport properties, making it a powerful tool for inferring material structure evolution [8].”
From A facility for thermo-mechanical characterization of fusion magnet materials during cryogenic ion irradiation (2025) · cites this paper as [8]
TGS is an optical technique that provides rapid diagnoses of thermomechanical properties, is inherently non-destructive, and operates on the length scales of ion irradiation damage.
“TGS is an optical technique that provides rapid diagnoses of thermomechanical properties, is inherently non-destructive, and operates on the length scales of ion irradiation damage [7, 8].”
From A facility for thermo-mechanical characterization of fusion magnet materials during cryogenic ion irradiation (2025) · cites this paper as [8]
TGS is a non-contact method for characterizing changes in elastic, acoustic, and thermal transport properties, making it a powerful tool for inferring material structure evolution.
“TGS is a non-contact method for characterizing changes in elastic, acoustic, and thermal transport properties, making it a powerful tool for inferring material structure evolution [8].”
From A facility for thermo-mechanical characterization of fusion magnet materials during cryogenic ion irradiation (2025) · cites this paper as [8]
TGS provides rapid, non-destructive diagnoses of thermomechanical properties and operates on the length scales of ion irradiation damage.
“TGS is an optical technique that provides rapid diagnoses of thermomechanical properties, is inherently non-destructive, and operates on the length scales of ion irradiation damage [7, 8].”
From A facility for thermo-mechanical characterization of fusion magnet materials during cryogenic ion irradiation (2025) · cites this paper as [8]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
The citation lists haven’t been fetched yet
References 81 · Cited by 74
Research works printed but not linked: 27
- [14]14. W. R. Corwin, G. E. Lucas, in ASTM Symposium on the Use of Nonstandard Subsized Specimens for Irradiated Testing (ASTM, Philadelphia, Pa., Albuquerque, N.M., 1986; https://inis.iaea.org/search/search.aspx?orig\_q=RN:18065732), p. 379.
- [17]17. K. Onizawa, K. Fukaya, Y. Nishiyama, M. Suzuki, S. Kaihara, T. Nakamura, Development of a reconstitution technique for Charpy impact - specimens by surface-activated joining for reactor pressure vessel surveillance. Int. J. Press. Vessel. Pip. 70 , 201-207 (1997).
- [25]25. V. F. Nesterenko, Dynamics of Heterogeneous Materials (Springer, New York, 2001; http://link.springer.com/10.1007/978-1-4757-3524-6). · DOI
- [28]28. J. C. Tan, B. Civalleri, C. C. Lin, L. Valenzano, R. Galvelis, P. F. Chen, T. - D. Bennett, C. Mellot-Draznieks, C. M. Zicovich-Wilson, A. K. Cheetham, Exceptionally low shear modulus in a prototypical imidazole-based metalorganic framework. Phys. Rev. Lett. 108 (2012), doi:10.1103/PhysRevLett.108.095502. · DOI
- [32]32. J. A. Johnson, A. A. Maznev, M. T. Bulsara, E. A. Fitzgerald, T. C. Harman, S. Calawa, C. J. Vinels, G. Turner, K. A. Nelson, J. Appl. Phys. , in press, doi:10.1063/1.3675467. · DOI
- [34]34. C. A. Dennett, M. P. Short, Time-resolved, dual heterodyne phase collection transient grating spectroscopy. Appl. Phys. Lett. 110 (2017), doi:10.1063/1.4983716. · DOI
- [35]35. F. Hofmann, D. R. Mason, J. K. Eliason, A. A. Maznev, K. A. Nelson, S. L. Dudarev, Non-Contact Measurement of Thermal Diffusivity in IonImplanted Nuclear Materials. Sci. Rep. 5 (2015), doi:10.1038/srep16042. · DOI · Paper page
- [37]37. A. G. Every, K. Y. Kim, A. A. Maznev, The elastodynamic response of a semi-infinite anisotropic solid to sudden surface loading. J. Acoust. Soc. Am. (1997), doi:10.1121/1.420053. · DOI
- [38]38. N. Favretto-Cristini, D. Komatitsch, J. M. Carcione, F. Cavallini, Elastic surface waves in crystals. Part 1: Review of the physics. Ultrasonics . 51 (2011), pp. 653-660.
- [39]39. X. Du, J. C. Zhao, Facile measurement of single-crystal elastic constants from polycrystalline samples. npj Comput. Mater. 3 (2017), doi:10.1038/s41524-017-0019-x. · DOI
- [45]45. J. Goossens, P. Leclaire, X. Xu, C. Glorieux, L. Martinez, A. Sola, C. Siligardi, V. Cannillo, T. Van der Donck, J.-P. Celis, J. Appl. Phys. , in press, doi:doi:http://dx.doi.org/10.1063/1.2774002. · DOI
- [46]46. J. A. Rogers, M. Fuchs, M. J. Banet, J. B. Hanselman, R. Logan, K. A. Nelson, Optical system for rapid materials characterization with the transient grating technique: Application to nondestructive evaluation of thin films used in microelectronics. Appl. Phys. Lett. 71 (1997), pp. 225227.
- [47]47. A. Vega-Flick, J. K. Eliason, A. A. Maznev, A. Khanolkar, M. Abi Ghanem, N. Boechler, J. J. Alvarado-Gil, K. A. Nelson, Laser-induced - transient grating setup with continuously tunable period. Rev. Sci. Instrum. 86 (2015), doi:10.1063/1.4936767. · DOI
- [48]48. C. A. Dennett, P. Cao, S. E. Ferry, A. Vega-Flick, A. A. Maznev, K. A. Nelson, A. G. Every, M. P. Short, Bridging the gap to mesoscale radiation materials science with transient grating spectroscopy. Phys. Rev. B . 94 (2016), doi:10.1103/PhysRevB.94.214106. · DOI · Paper page
- [54]54. Y. Xu, T. Aizawa, J. Kihara, Simultaneous determination of elastic constants and crystallographic orientation in coarse-grained Nickel by acoustic spectro-microscopy. Mater. Trans. - JIM . 38 , 536-545 (1997).
- [56]56. F. Hofmann, D. Nguyen-Manh, M. R. Gilbert, C. E. Beck, J. K. Eliason, A. A. Maznev, W. Liu, D. E. J. Armstrong, K. A. Nelson, S. L. Dudarev, Lattice swelling and modulus change in a helium-implanted tungsten alloy: X-ray micro-diffraction, surface acoustic wave measurements, and multiscale modelling. Acta Mater. 89 (2015), doi:10.1016/j.actamat.2015.01.055. · DOI
- [60]60. R. A. Duncan, F. Hofmann, A. Vega-Flick, J. K. Eliason, A. A. Maznev, A. G. Every, K. A. Nelson, Increase in elastic anisotropy of single crystal tungsten upon He-ion implantation measured with laser-generated surface acoustic waves. Appl. Phys. Lett. 109 (2016), doi:10.1063/1.4964709. · DOI
- [66]66. N. Boechler, J. K. Eliason, A. Kumar, A. A. Maznev, K. A. Nelson, N. Fang, Interaction of a contact resonance of microspheres with surface acoustic waves. Phys. Rev. Lett. 111 (2013), doi:10.1103/PhysRevLett.111.036103. · DOI
- [67]67. P. H. Otsuka, S. Mezil, O. Matsuda, M. Tomoda, A. A. Maznev, T. Gan, N. Fang, N. Boechler, V. E. Gusev, O. B. Wright, Time-domain imaging of gigahertz surface waves on an acoustic metamaterial. New J. Phys. 20 (2018), doi:10.1088/1367-2630/aa9298. · DOI
- [68]68. M. Hiraiwa, M. Abi Ghanem, S. P. Wallen, A. Khanolkar, A. A. Maznev, N. Boechler, Complex Contact-Based Dynamics of Microsphere Monolayers Revealed by Resonant Attenuation of Surface Acoustic Waves. Phys. Rev. Lett. 116 (2016), doi:10.1103/PhysRevLett.116.198001. · DOI
- [69]69. J. K. Eliason, A. Vega-Flick, M. Hiraiwa, A. Khanolkar, T. Gan, N. Boechler, N. Fang, K. A. Nelson, A. A. Maznev, Resonant attenuation of surface acoustic waves by a disordered monolayer of microspheres. Appl. Phys. Lett. 108 (2016), doi:10.1063/1.4941808. · DOI
- [72]72. J. M. Ziman, Electrons and Phonons: The Theory of Transport Phenomena in Solids (Oxford University Press, Oxford, 2001).
- [73]73. D. G. Cahill, W. K. Ford, K. E. Goodson, G. D. Mahan, A. Majumdar, H. J. Maris, R. Merlin, S. R. Phillpot, Nanoscale thermal transport. J. Appl. Phys. 93 (2003), pp. 793-818.
- [76]76. K. Nordlund, S. J. Zinkle, A. E. Sand, F. Granberg, R. S. Averback, R. E. Stoller, T. Suzudo, L. Malerba, F. Banhart, W. J. Weber, F. Willaime, S. L. Dudarev, D. Simeone, Primary radiation damage: A review of current understanding and models. J. Nucl. Mater. 512 (2018), pp. 450-479.
- [78]78. S. E. Ferry, thesis, Massachusetts Institute of Technology (2018).
- [83]83. J. S. Blakemore, Solid State Physics (Cambridge University Press, Cambridge, ed. 2, 1985; https://www.cambridge.org/core/books/solid-statephysics/50A3861A5268A48C385EF6E78AF5BBFB).
- [86]86. J. A. Johnson, J. K. Eliason, A. A. Maznev, T. Luo, K. A. Nelson, Nondiffusive thermal transport in GaAs at micron length scales. J. Appl. Phys. 118 (2015), doi:10.1063/1.4933285. · DOI
- Authors
- Hofmann, F., Short, M. P., & Dennett, C. A.
- Affiliations
- University of Oxford (GB)
- Massachusetts Institute of Technology (US)
- Corresponding author
- Hofmann, Felix
- Venue
- MRS Bulletin
- Published
- 2019-05
- Volume
- 44
- Issue
- 5
- Pages
- 392-402
- ISSN
- 0883-7694 (ISSN-L)
- 1938-1425
- OpenAlex
- W2944644164
- Cited by
- 74
- References
- 81
- Citations by year
- 2026: 9 · 2025: 14 · 2024: 15 · 2023: 9 · 2022: 8 · 2021: 12 · 2020: 4 · 2019: 3
- FWCI
- 2.97
- Type
- journal article
- Language
- en
- Open access
- green
- arxiv.org
- Locations
- MRS Bulletin (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- DSpace@MIT (Massachusetts Institute of Technology) (submittedVersion, cc-by-nc-sa)
- arXiv (Cornell University)
- Funders
- U.S. Department of Energy (DENA0003864)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Laser-Matter Interactions and Applications
- Physical Sciences › Engineering › Mechanics of Materials › Thermography and Photoacoustic Techniques
- Physical Sciences › Engineering › Computational Mechanics › Laser Material Processing Techniques
- Keywords
- transient grating spectroscopy, ultrafast spectroscopy, material characterization
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review