In vivo Near-infrared Raman Spectroscopy: Demonstration of Feasibility During Clinical Gastrointestinal Endoscopy ¶
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Raman spectroscopy (RS) has potential for disease classification within the gastrointestinal tract (GI). A near-infrared (NIR) fiber-optic RS system has been developed previously. This study reports the first in vivo Raman spectra of human gastrointestinal tissues measured during routine clinical endoscopy. This was achieved by using this system with a fiber-optic probe that was passed through the endoscope instrument channel and placed in contact with the tissue surface. Spectra could be obtained with good signal-to-noise ratio in 5 s. The effects on the spectra of varying the pressure of the probe tip on the tissue and of the probe-tissue angle were determined and shown to be insignificant. The limited set of spectra from normal and diseased tissues revealed only subtle differences. Therefore, powerful spectral-sorting algorithms, successfully implemented in prior ex vivo studies, are required to realize the full diagnostic potential of RS for tissue classification in the GI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Levine, D. S., Haggitt, R. C., Blount, P. L., Rabinovitch, P. S., Rusch, V. W., & Reid, B. J. (1993) · Gastroenterology · doi:10.1016/0016-5085(93)90008-z · Cited by 622
Raman spectroscopy for the detection of cancers and precancers
Mahadevan-Jansen, A. (1996) · Journal of Biomedical Optics · doi:10.1117/12.227815 · Cited by 475
Value of endoscopic surveillance in the detection of neoplastic change in Barrett's oesophagus
ROBERTSON, C. S., Mayberry, J. F., Nicholson, D. A., et al. (1988) · British journal of surgery · doi:10.1002/bjs.1800750813 · Cited by 273
Raman Spectroscopy and Fluorescence Photon Migration for Breast Cancer Diagnosis and Imaging
Manoharan, R., Shafer, K., Perelman, L., Wu, J., Chen, K., Deinum, G., Fitzmaurice, M., Myles, J., Crowe, J., Dasarl, R. R., et al. (1998) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1998.tb05160.x · Cited by 170
Development of anIn Vivo Raman Spectroscopic System for Diagnostic Applications
Shim, M. G., & Wilson, B. C. (1997) · Journal of Raman Spectroscopy · doi:10.1002/(sici)1097-4555(199702)28:2/3<131::aid-jrs68>3.0.co;2-s · Cited by 132
Self-citationRaman spectrometry and neural networks for the classification of wood types—1
Lewis, I. R., Daniel, N., Chaffin, N. C., & Griffiths, P. R. (1994) · Spectrochimica Acta Part A Molecular Spectroscopy · doi:10.1016/0584-8539(94)80207-6 · Cited by 68
Light-Induced Fluorescence Endoscopy of the Gastrointestinal Tract
DaCosta, R. S., Wilson, B. C., & Marcon, N. E. (2000) · Gastrointestinal Endoscopy Clinics of North America · doi:10.1016/s1052-5157(18)30146-6 · Cited by 57
Self-citationOzaki, Y., Mizuno, A., Sato, H., Kawauchi, K., & Muraishi, S. (1992) · Applied Spectroscopy · doi:10.1366/0003702924125131 · Cited by 36
Cited by
Coherent Anti-Stokes Raman Scattering Microscopy: Chemical Imaging for Biology and Medicine
Evans, C. L., & Xie, X. S. (2008) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.112754 · Cited by 1,150
A Molecular Imaging Primer: Modalities, Imaging Agents, and Applications
James, M. L., & Gambhir, S. S. (2012) · Physiological Reviews · doi:10.1152/physrev.00049.2010 · Cited by 1,140
Near‐infrared Raman spectroscopy for optical diagnosis of lung cancer
Huang, Z., McWilliams, A., Lui, H., McLean, D. I., Lam, S., & Zeng, H. (2003) · International Journal of Cancer · doi:10.1002/ijc.11500 · Cited by 821
Kong, K., Kendall, C., Stone, N., & Notingher, I. (2015) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.03.009 · Cited by 653
Intraoperative brain cancer detection with Raman spectroscopy in humans
Jermyn, M., Mok, K., Mercier, J., Desroches, J., Pichette, J., Saint-Arnaud, K., Bernstein, L., Guiot, M.-C., Petrecca, K., & Leblond, F. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aaa2384 · Cited by 618
Ellis, D. I., & Goodacre, R. (2006) · The Analyst · doi:10.1039/b602376m · Cited by 614
Near‐infrared Raman spectroscopy for the classification of epithelial pre‐cancers and cancers
Stone, N., Kendall, C., Shepherd, N., Crow, P., & Barr, H. (2002) · Journal of Raman Spectroscopy · doi:10.1002/jrs.882 · Cited by 472
Fiber optic probes for biomedical optical spectroscopy
Utzinger, U., & Richards-Kortum, R. R. (2003) · Journal of Biomedical Optics · doi:10.1117/1.1528207 · Cited by 443
Surface-enhanced Raman spectroscopy for in vivo biosensing
Laing, S., Jamieson, L. E., Faulds, K., & Graham, D. (2017) · Nature Reviews Chemistry · doi:10.1038/s41570-017-0060 · Cited by 442
In vivo Margin Assessment during Partial Mastectomy Breast Surgery Using Raman Spectroscopy
Haka, A. S., Volynskaya, Z., Gardecki, J. A., Nazemi, J., Lyons, J., Hicks, D., Fitzmaurice, M., Dasari, R. R., Crowe, J. P., & Feld, M. S. (2006) · Cancer Research · doi:10.1158/0008-5472.can-05-2815 · Cited by 424
Metabolic Fingerprinting As A Diagnostic Tool
Ellis, D. I., Dunn, W. B., Griffin, J. L., Allwood, J. W., & Goodacre, R. (2007) · Pharmacogenomics · doi:10.2217/14622416.8.9.1243 · Cited by 396
Developing and understanding biofluid vibrational spectroscopy: a critical review
Baker, M. J., Hussain, S. R., Lovergne, L., Untereiner, V., Hughes, C., Lukaszewski, R. A., Thiéfin, G., & Sockalingum, G. D. (2016) · Chemical Society Reviews · doi:10.1039/c5cs00585j · Cited by 358
Gniadecka, M., Philipsen, P. A., Wessel, S., Gniadecki, R., Wulf, H. C., Sigurdsson, S., Nielsen, O. F., Christensen, D. H., Hercogova, J., Rossen, K., et al. (2004) · Journal of Investigative Dermatology · doi:10.1046/j.0022-202x.2004.22208.x · Cited by 350
Vibrational spectroscopy: a clinical tool for cancer diagnostics
Kendall, C., Isabelle, M., Bazant-Hegemark, F., Hutchings, J., Orr, L., Babrah, J., Baker, R., & Stone, N. (2009) · The Analyst · doi:10.1039/b822130h · Cited by 293
Disease recognition by infrared and Raman spectroscopy
Krafft, C., Steiner, G., Beleites, C., & Salzer, R. (2009) · Journal of Biophotonics · doi:10.1002/jbio.200810024 · Cited by 285
Medical applications of Raman spectroscopy: From proof of principle to clinical implementation
Choo‐Smith, L. ‐., Edwards, H. G. M., Endtz, H. P., Kros, J. M., Heule, F., Barr, H., Robinson, J. S., Bruining, H. A., & Puppels, G. J. (2002) · Biopolymers · doi:10.1002/bip.10064 · Cited by 280
Raman and CARS microspectroscopy of cells and tissues
Krafft, C., Dietzek, B., & Popp, J. (2009) · The Analyst · doi:10.1039/b822354h · Cited by 271
Molckovsky, A., Song, L.-M. W. K., Shim, M. G., Marcon, N. E., & Wilson, B. C. (2003) · Gastrointestinal Endoscopy · doi:10.1067/mge.2003.105 · Cited by 265
Self-citationNear-Infrared Raman Spectroscopy for in vivo Detection of Cervical Precancers
Utzinger, U., Heintzelman, D. L., Mahadevan-Jansen, A., Malpica, A., Follen, M., & Richards-Kortum, R. (2001) · Applied Spectroscopy · doi:10.1366/0003702011953018 · Cited by 251
Optical Fiber Probe for Biomedical Raman Spectroscopy
Motz, J. T., Hunter, M., Galindo, L. H., Gardecki, J. A., Kramer, J. R., Dasari, R. R., & Feld, M. S. (2004) · Applied Optics · doi:10.1364/ao.43.000542 · Cited by 248
Kendall, C., Stone, N., Shepherd, N., Geboes, K., Warren, B., Bennett, R., & Barr, H. (2003) · The Journal of Pathology · doi:10.1002/path.1376 · Cited by 245
Clinical applications of infrared and Raman spectroscopy: state of play and future challenges
Baker, M. J., Byrne, H. J., Chalmers, J., Gardner, P., Goodacre, R., Henderson, A., Kazarian, S. G., Martin, F. L., Moger, J., Stone, N., et al. (2018) · The Analyst · doi:10.1039/c7an01871a · Cited by 230
Teh, S. K., Zheng, W., Ho, K. Y., Teh, M., Yeoh, K. G., & Huang, Z. (2008) · British Journal of Cancer · doi:10.1038/sj.bjc.6604176 · Cited by 230
Surface enhanced Raman spectroscopy and its application to molecular and cellular analysis
Huh, Y. S., Chung, A. J., & Erickson, D. (2009) · Microfluidics and Nanofluidics · doi:10.1007/s10404-008-0392-3 · Cited by 217
“In another approach, Shim et al. (2000) reported the first in vivo Raman spectra of human gastrointestinal (GI) tissues measured during routine clinical endoscopy.”
BackgroundCrow, P., Molckovsky, A., Stone, N., Uff, J., Wilson, B., & WongKeeSong, L.-M. (2005) · Urology · doi:10.1016/j.urology.2004.12.058 · Cited by 208
Self-citationBiomedical applications of Raman and infrared spectroscopy to diagnose tissues
Krafft, C., & Sergo, V. (2006) · Journal of Spectroscopy · doi:10.1155/2006/738186 · Cited by 206
Optical biopsy: A new frontier in endoscopic detection and diagnosis
Wang, T. D., & Van Dam, J. (2004) · Clinical Gastroenterology and Hepatology · doi:10.1016/s1542-3565(04)00345-3 · Cited by 202
Rapid near-infrared Raman spectroscopy system for real-time in vivo skin measurements
Huang, Z., Zeng, H., Hamzavi, I., McLean, D. I., & Lui, H. (2001) · Optics Letters · doi:10.1364/ol.26.001782 · Cited by 197
In Vivo Bladder Cancer Diagnosis by High-Volume Raman Spectroscopy
Draga, R. O. P., Grimbergen, M. C. M., Vijverberg, P. L. M., Swol, C. F. P. V., Jonges, T. G. N., Kummer, J. A., & Ruud Bosch, J. L. H. (2010) · Analytical Chemistry · doi:10.1021/ac100448p · Cited by 196
Illuminating disease and enlightening biomedicine: Raman spectroscopy as a diagnostic tool
Ellis, D. I., Cowcher, D. P., Ashton, L., O'Hagan, S., & Goodacre, R. (2013) · The Analyst · doi:10.1039/c3an00698k · Cited by 194
Advances in Lipidomics for Cancer Biomarkers Discovery
Perrotti, F., Rosa, C., Cicalini, I., Sacchetta, P., Del Boccio, P., Genovesi, D., & Pieragostino, D. (2016) · International Journal of Molecular Sciences · doi:10.3390/ijms17121992 · Cited by 188
Advances in the clinical application of Raman spectroscopy for cancer diagnostics
Kallaway, C., Almond, L. M., Barr, H., Wood, J., Hutchings, J., Kendall, C., & Stone, N. (2013) · Photodiagnosis and Photodynamic Therapy · doi:10.1016/j.pdpdt.2013.01.008 · Cited by 186
Lau, D. P., Huang, Z., Lui, H., Man, C. S., Berean, K., Morrison, M. D., & Zeng, H. (2003) · Lasers in Surgery and Medicine · doi:10.1002/lsm.10084 · Cited by 185
Blood analysis by Raman spectroscopy
Enejder, A. M. K., Koo, T.-W., Oh, J., Hunter, M., Sasic, S., Feld, M. S., & Horowitz, G. L. (2002) · Optics Letters · doi:10.1364/ol.27.002004 · Cited by 184
Bergholt, M. S., Zheng, W., Ho, K. Y., Teh, M., Yeoh, K. G., Yan So, J. B., Shabbir, A., & Huang, Z. (2014) · Gastroenterology · doi:10.1053/j.gastro.2013.11.002 · Cited by 159
Metadata
- Authors
- Shim, M. G., Wong Kee Song, L.-M., Marcon, N. E., & Wilson, B. C.
- Venue
- Photochemistry and Photobiology
- Publisher
- American Society for Photobiology
- Published
- 2000-07
- Volume
- 72
- Issue
- 1
- Pages
- 146-150
- ISSN
- 0031-8655 (ISSN-L)
- OpenAlex
- W2102792305
- Cited by
- 296
- References
- 8
- FWCI
- 7.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.