Hydrophilic Cyanine Dyes as Contrast Agents for Near-infrared Tumor Imaging: Synthesis, Photophysical Properties and Spectroscopic In vivo Characterization ¶
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
We have synthesized a group of glucamine and gluosamine-substituted cyanine dyes structurally related to indocyanine green (ICG) and have characterized these compounds with regard to their potential as contrast agents for biomedical optical imaging. The compounds reported herein exhibit increased hydrophilicity and less plasma protein binding (< 50%), and are thus expected to have different pharmacokinetic properties compared with ICG. Furthermore, we measured enhanced fluorescence quantum yields (7-15%) in a physiological environment with respect to ICG. For the derivative with the highest hydrophilicity (5a) the efflux from tumor and normal tissue was monitored by intensity-modulated diffuse optical spectroscopy after intravenous injection into tumor-bearing rats. In comparison with ICG, 5a exhibited a considerably enhanced tissue-efflux half-life (73 min versus less than 10 min for ICG in tumor tissue), a two-fold higher initial tissue absorption coefficient compared to ICG, and finally, it generated an elevated tumor-to-tissue concentration gradient up to 1 h after injection. In conclusion, compounds such as 5a are promising contrast agents for optical imaging, and could facilitate highly sensitive and specific detection of breast cancer or other malignancies by utilizing mechanisms similar to contrast-enhanced magnetic resonance imaging or computerized tomography.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Light-absorbing properties, stability, and spectral stabilization of indocyanine green
Landsman, M. L., Kwant, G., Mook, G. A., & Zijlstra, W. G. (1976) · Journal of Applied Physiology · doi:10.1152/jappl.1976.40.4.575 · Cited by 834 · cited 1×
“Additionally, insufficient stability of aqueous solutions accompanied by rather poor fluorescence efficiency is reported for ICG (18,19).”
BackgroundConcurrent MRI and diffuse optical tomography of breast after indocyanine green enhancement
Ntziachristos, V., Yodh, A. G., Schnall, M., & Chance, B. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.040570597 · Cited by 793
Self-citationCAESAR, J., Shaldon, S., Chiandussi, L., Guevara, L., & Sherlock, S. (1961) · PubMed · Cited by 761
Frequency-domain techniques enhance optical mammography: Initial clinical results
Franceschini, M. A., Moesta, K. T., Fantini, S., Gaida, G., Gratton, E., Jess, H., Mantulin, W. W., Seeber, M., Schlag, P. M., & Kaschke, M. F. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.12.6468 · Cited by 355
Safety of magnetic resonance imaging contrast agents
Shellock, F. G., & Kanal, E. (1999) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(199909)10:3<477::aid-jmri33>3.0.co;2-e · Cited by 321
A new lipophilic gadolinium chelate as a tissue‐specific contrast medium for MRI
Weinmann, H. ‐., Schuhmann‐Giampieri, G., Schmitt‐Willich, H., Vogler, H., Frenzel, T., & Gries, H. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910220214 · Cited by 237 · cited 1×
“The well-characterized X-ray and MRI agents show negligible plasma protein interaction, are highly soluble in aqueous solvents and thus exhibit high tolerability (30,31).”
BackgroundCyanine-Labeling Reagents: Sulfobenzindocyanine Succinimidyl Esters
Mujumdar, S. R., Mujumdar, R. B., Grant, C. M., & Waggoner, A. S. (1996) · Bioconjugate Chemistry · doi:10.1021/bc960021b · Cited by 232
Imaging of Spontaneous Canine Mammary Tumors Using Fluorescent Contrast Agents
Reynolds, J. S., Troy, T. L., Mayer, R. H., Thompson, A. B., Waters, D. J., Cornell, K. K., Snyder, P. W., & Sevick-Muraca, E. M. (1999) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1999.tb01953.x · Cited by 204 · cited 1×
“tion of tumors in both animal models (14) and in humans”
BackgroundAbsorption and fluorescence properties of cyanine dyes
Benson, R. C., & Kues, H. A. (1977) · Journal of Chemical & Engineering Data · doi:10.1021/je60075a020 · Cited by 202 · cited 5×
“Acceptable fluorescence quantum yields in organic solvents were reported for ICG, e.g. 0.13 in DMSO (23), but the fluorescence undergoes a significant decline when the dye is dissolved in water or saline.”
BackgroundInfluentialSoper, S. A., & Mattingly, Q. L. (1994) · Journal of the American Chemical Society · doi:10.1021/ja00088a010 · Cited by 197 · cited 2×
“(19), whereas dilution in plasma resulted in a significantly”
BackgroundFrequency-domain optical absorption spectroscopy of finite tissue volumes using diffusion theory
Pogue, B. W., & Patterson, M. S. (1994) · Physics in Medicine and Biology · doi:10.1088/0031-9155/39/7/008 · Cited by 184
Enhanced Optical Imaging of Human Gliomas and Tumor Margins
Haglund, M. M., Berger, M. S., & Hochman, D. W. (1996) · Neurosurgery · doi:10.1097/00006123-199602000-00015 · Cited by 184
Optical properties of normal and diseased breast tissues: prognosis for optical mammography
Troy, T. L. (1996) · Journal of Biomedical Optics · doi:10.1117/12.239905 · Cited by 163 · cited 1×
“Consequently, a reliable tissue characterization based on intrinsic absorption and scattering inhomogeneities is often difficult, particularly with respect to differentiation between benign and malignant lesions (3,9).”
BackgroundMcBride, T. O., Pogue, B. W., Gerety, E. D., Poplack, S. P., Österberg, U. L., & Paulsen, K. D. (1999) · Applied Optics · doi:10.1364/ao.38.005480 · Cited by 148
Non-invasive vascular imaging: assessing tumour vascularity
Delorme, S., & Knopp, M. V. (1998) · European Radiology · doi:10.1007/s003300050428 · Cited by 146 · cited 1×
“Contrast-enhancing properties mainly rely upon a more distinct perfusion of tumor tissue compared to normal areas (10,34).”
BackgroundTerpetschnig, E., Szmacinski, H., Ozinskas, A. J., & Lakowicz, J. R. (1994) · Analytical Biochemistry · doi:10.1006/abio.1994.1109 · Cited by 127 · cited 1×
“5-Carboxy-1-(4-sulfobutyl)2,3,3-trimethyl-3H-indolenine (1) and 1-(4-sulfobutyl)-2,3,3-trimethyl-3H-indolenine (2) were synthesized according to the literature (21,22).”
MethodPharmacokinetics of biliary excretion in man. VI. Indocyanine green
Meijer, D. K. F., Weert, B., & Vermeer, G. A. (1988) · European Journal of Clinical Pharmacology · doi:10.1007/bf00558268 · Cited by 122
Multichannel photon counting instrument for spatially resolved near infrared spectroscopy
Ntziachristos, V., Ma, X., Yodh, A. G., & Chance, B. (1999) · Review of Scientific Instruments · doi:10.1063/1.1149565 · Cited by 93
Self-citationTumor Detection and Visualization Using Cyanine Fluorochrome-Labeled Antibodies
Ballou, B. T., Fisher, G. W., Hakala, T. R., & Farkas, D. L. (1997) · Biotechnology Progress · doi:10.1021/bp970088t · Cited by 77 · cited 2×
“CyDyes, Amersham Pharmacia Biotech, UK) (20) we decided to closely follow the structure of ICG and perform systematic structural modifications on the exterior ring positions of the bis-1,19-(4-sulfobutyl)indotricarbocyanine chromophore.”
MethodContrast features of breast cancer in frequency-domain laser scanning mammography
Moesta, K. T., Fantini, S., Jess, H., Totkas, S., Franceschini, M. A., Kaschke, M. F., & Schlag, P. M. (1998) · Journal of Biomedical Optics · doi:10.1117/1.429869 · Cited by 62 · cited 7×
“Photochemistry and Photobiology, 2000, 72(3) 397”
BackgroundInfluentialTime-resolved transillumination and optical tomography
de Haller, E. B. (1996) · Journal of Biomedical Optics · doi:10.1117/12.227112 · Cited by 57
Breast tumor detection using continuous wave light source
Zhao, S., O'Leary, M. A., Nioka, S., & Chance, B. (1995) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.210024 · Cited by 17
Self-citation
Cited by
Shedding light onto live molecular targets
Weissleder, R., & Ntziachristos, V. (2003) · Nature Medicine · doi:10.1038/nm0103-123 · Cited by 1,909
Self-citationAdvances in In Vivo Bioluminescence Imaging of Gene Expression
Contag, C. H., & Bachmann, M. H. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.111901.093336 · Cited by 870
Sharma, P., Brown, S., Walter, G., Santra, S., & Moudgil, B. (2006) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2006.05.026 · Cited by 755
Receptor-targeted optical imaging of tumors with near-infrared fluorescent ligands
Becker, A., Hessenius, C., Licha, K., Ebert, B., Sukowski, U., Semmler, W., Wiedenmann, B., & Grötzinger, C. (2001) · Nature Biotechnology · doi:10.1038/86707 · Cited by 518
Self-citationMultimodality Molecular Imaging of Tumor Angiogenesis
Cai, W., & Chen, X. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.045922 · Cited by 494
Metadata
- Authors
- Licha, K., Riefke, B., Ntziachristos, V., Becker, A., Chance, B., & Semmler, W.
- Venue
- Photochemistry and Photobiology
- Publisher
- American Society for Photobiology
- Published
- 2007-05-01
- Volume
- 72
- Issue
- 3
- Pages
- 392-398
- ISSN
- 0031-8655 (ISSN-L)
- OpenAlex
- W1947700761
- Cited by
- 238
- References
- 22
- FWCI
- 13.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.