Bioabsorbable fixation devices in trauma and bone surgery: current clinical standing
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Bioabsorbable fixation devices are increasingly used in trauma, orthopedic and craniomaxillofacial surgery. The devices are essentially made of polylactic acid and/or polyglycolic acid polymers. Ultra-high-strength implants are manufactured from such polymers using self-reinforcing techniques. Implants are available for stabilization of fractures, osteotomies, bone grafts and fusions, as well as for reattachment of ligaments, tendons, meniscal tears and other soft tissue structures. As these implants are completely absorbed, the need for a removal operation is overcome and long-term interference with tendons, nerves and the growing skeleton is avoided. The risk of implant-associated stress shielding, peri-implant osteoporosis and infections is reduced. Implants do not interfere with clinical imaging. Current clinical use of bioabsorbable devices is reviewed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Late degradation tissue response to poly(?-lactide) bone plates and screws
Bergsma, J. (1995) · Biomaterials · doi:10.1016/0142-9612(95)91092-d · Cited by 799
Bioabsorbable Miniplating Versus Metallic Fixation for Metacarpal Fractures
Waris, E., Ashammakhi, N., Happonen, H., Raatikainen, T., Kaarela, O., Törmälä, P., Santavirta, S., & Konttinen, Y. T. (2003) · Clinical Orthopaedics & Related Research · doi:10.1097/01.blo.0000063789.32430.c6 · Cited by 58
Self-citation
Cited by
Poly-lactic acid synthesis for application in biomedical devices — A review
Lasprilla, A. J. R., Martinez, G. A. R., Lunelli, B. H., Jardini, A. L., & Filho, R. M. (2012) · Biotechnology Advances · doi:10.1016/j.biotechadv.2011.06.019 · Cited by 1,174
Polylactic acid: Synthesis and biomedical applications
Singhvi, M. S., Zinjarde, S. S., & Gokhale, D. V. (2019) · Journal of Applied Microbiology · doi:10.1111/jam.14290 · Cited by 883
Poly (Lactic Acid) Production for Tissue Engineering Applications
Lopes, M. S., Jardini, A. L., & Filho, R. M. (2012) · Procedia Engineering · doi:10.1016/j.proeng.2012.07.534 · Cited by 457
Han, P., Cheng, P., Zhang, S., Zhao, C., Ni, J., Zhang, Y., Zhong, W., Hou, P., Zhang, X., Zheng, Y., et al. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.06.031 · Cited by 249
“It has also been supposed that high molecular weight, partially-crystalline PLLA disintegrates into polymer fragments with high crystallinity and therefore provoke a prolonged inflammation and foreignebody reaction [45].”
Yakacki, C. M., Lyons, M. B., Rech, B., Gall, K., & Shandas, R. (2008) · Biomedical Materials · doi:10.1088/1748-6041/3/1/015010 · Cited by 50
“Devices utilizing one or more functionalities include biodegradable implants [2, 3], drug-delivering biomaterials [4, 5], intelligent hydrogels [6] and shape-memory polymers (SMPs) [7, 8].”
Background
Metadata
- Authors
- Waris, E., Konttinen, Y. T., Ashammakhi, N., Suuronen, R., & Santavirta, S.
- Venue
- Expert Review of Medical Devices
- Publisher
- Informa UK Limited
- Published
- 2004-11
- Volume
- 1
- Issue
- 2
- Pages
- 229-240
- ISSN
- 1743-4440 (ISSN-L)
- 1745-2422
- OpenAlex
- W2117067604
- Cited by
- 84
- References
- 2
- FWCI
- 1.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.