Scaffolds for tendon and ligament repair: review of the efficacy of commercial products
The DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Abstract
Driven by market demand, many biological and synthetic scaffolds have been developed during the last 15 years. Both positive and negative results have been reported in clinical applications for tendon and ligament repair. To obtain data for this review, multiple electronic databases were used (e.g., Pubmed and ScienceDirect), as well as the US FDA website and the reference lists from clinical trials, review articles and company reports, in order to identify studies relating to the use of these commercial scaffolds for tendon and ligament repair. The commercial names of each scaffold and the keywords 'tendon' and 'ligament' were used as the search terms. Initially, 378 articles were identified. Of these, 47 were clinical studies and the others were reviews, editorials, commentaries, animal studies or related to applications other than tendons and ligaments. The outcomes were reviewed in 47 reports (six on Restore, eight on Graftjacket, four on Zimmer, one on TissueMend, five on Gore-Tex, six on Lars, 18 on Leeds-Keio and one study used both Restore and Graftjacket). The advantages, disadvantages and future perspectives regarding the use of commercial scaffolds for tendon and ligament treatment are discussed. Both biological and synthetic scaffolds can cause adverse events such as noninfectious effusion and synovitis, which result in the failure of surgery. Future improvements should focus on both mechanical properties and biocompatibility. Nanoscaffold manufactured using electrospinning technology may provide great improvement in future practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Scaffolds in tissue engineering bone and cartilage
Hutmacher, D. W. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00121-6 · Cited by 4,994
Electrospinning of Collagen Nanofibers
Matthews, J. A., Wnek, G. E., Simpson, D. G., & Bowlin, G. L. (2002) · Biomacromolecules · doi:10.1021/bm015533u · Cited by 2,251
Age-related prevalence of rotator cuff tears in asymptomatic shoulders
Tempelhof, S., Rupp, S., & Seil, R. (1999) · Journal of Shoulder and Elbow Surgery · doi:10.1016/s1058-2746(99)90148-9 · Cited by 930
Rotator-cuff changes in asymptomatic adults. The effect of age, hand dominance and gender
Milgrom, C., Schaffler, M., Gilbert, S., & van Holsbeeck, M. (1995) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.77b2.7706351 · Cited by 852
Cell movements : from molecules to motility
Bray, D. (1992) · Cited by 674
Current Concepts Review - The Science of Reconstruction of the Anterior Cruciate Ligament*
FRANK, C. B., & JACKSON, D. W. (1997) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199710000-00014 · Cited by 622
Current concepts in the management of tendon disorders
Rees, J. D., Wilson, A. M., & Wolman, R. L. (2006) · Rheumatology · doi:10.1093/rheumatology/kel046 · Cited by 515
Badylak, S. F., Tullius, R., Kokini, K., Shelbourne, K. D., Klootwyk, T., Voytik, S. L., Kraine, M. R., & Simmons, C. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820290809 · Cited by 501
Enhancement of neurite outgrowth using nano-structured scaffolds coupled with laminin
Koh, H. S., Yong, T., Chan, C. K., & Ramakrishna, S. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.05.014 · Cited by 493
Encyclopedia of Medical Devices and Instrumentation
(2006) · Wiley eBooks · doi:10.1002/0471732877 · Cited by 481
Cited by
Applications of synthetic polymers in clinical medicine
Maitz, M. F. (2015) · Biosurface and Biotribology · doi:10.1016/j.bsbt.2015.08.002 · Cited by 726
Kular, J. K., Basu, S., & Sharma, R. I. (2014) · Journal of Tissue Engineering · doi:10.1177/2041731414557112 · Cited by 559
How smart do biomaterials need to be? A translational science and clinical point of view
Holzapfel, B. M., Reichert, J. C., Schantz, J.-T., Gbureck, U., Rackwitz, L., Nöth, U., Jakob, F., Rudert, M., Groll, J., & Hutmacher, D. W. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.07.009 · Cited by 552
Therapeutic Strategies for Tendon Healing Based on Novel Biomaterials, Factors and Cells
Gross, G., & Hoffmann, A. (2013) · Pathobiology · doi:10.1159/000347059 · Cited by 467
Biomimetic Scaffolds for Tissue Engineering
Kim, T. G., Shin, H., & Lim, D. W. (2012) · Advanced Functional Materials · doi:10.1002/adfm.201103083 · Cited by 459
Hydrogel-based commercial products for biomedical applications: A review
Cascone, S., & Lamberti, G. (2020) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2019.118803 · Cited by 421
Blakeney, B. A., Tambralli, A., Anderson, J. M., Andukuri, A., Lim, D.-J., Dean, D. R., & Jun, H.-W. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2010.10.056 · Cited by 372
Tendon augmentation grafts: a systematic review
Longo, U. G., Lamberti, A., Maffulli, N., & Denaro, V. (2010) · British Medical Bulletin · doi:10.1093/bmb/ldp051 · Cited by 280
Xie, J., Li, X., Lipner, J., Manning, C. N., Schwartz, A. G., Thomopoulos, S., & Xia, Y. (2010) · Nanoscale · doi:10.1039/c0nr00192a · Cited by 242
Role of Biomaterials and Controlled Architecture on Tendon/Ligament Repair and Regeneration
No, Y. J., Castilho, M., Ramaswamy, Y., & Zreiqat, H. (2020) · Advanced Materials · doi:10.1002/adma.201904511 · Cited by 205
Regeneration and repair of tendon and ligament tissue using collagen fibre biomaterials
Kew, S. J., Gwynne, J. H., Enea, D., Abu-Rub, M., Pandit, A., Zeugolis, D., Brooks, R. A., Rushton, N., Best, S. M., & Cameron, R. E. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.06.002 · Cited by 192
Stone, K. R., Walgenbach, A., & Galili, U. (2017) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2016.0332 · Cited by 22
Metadata
- Authors
- Chen, J., Xu, J., Wang, A., & Zheng, M.
- Venue
- Expert Review of Medical Devices
- Publisher
- Informa UK Limited
- Published
- 2009-01
- Volume
- 6
- Issue
- 1
- Pages
- 61-73
- ISSN
- 1743-4440 (ISSN-L)
- 1745-2422
- OpenAlex
- W2111174701
- Cited by
- 342
- References
- 53
- FWCI
- 8.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.