The DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Scaffolds for tendon and ligament repair: review of the efficacy of commercial products
Abstract
Driven by market demand, many biological and synthetic scaffolds have been developed during the last 15 years. Both positive and negative results have been reported in clinical applications for tendon and ligament repair. To obtain data for this review, multiple electronic databases were used (e.g., Pubmed and ScienceDirect), as well as the US FDA website and the reference lists from clinical trials, review articles and company reports, in order to identify studies relating to the use of these commercial scaffolds for tendon and ligament repair. The commercial names of each scaffold and the keywords 'tendon' and 'ligament' were used as the search terms. Initially, 378 articles were identified. Of these, 47 were clinical studies and the others were reviews, editorials, commentaries, animal studies or related to applications other than tendons and ligaments. The outcomes were reviewed in 47 reports (six on Restore, eight on Graftjacket, four on Zimmer, one on TissueMend, five on Gore-Tex, six on Lars, 18 on Leeds-Keio and one study used both Restore and Graftjacket). The advantages, disadvantages and future perspectives regarding the use of commercial scaffolds for tendon and ligament treatment are discussed. Both biological and synthetic scaffolds can cause adverse events such as noninfectious effusion and synovitis, which result in the failure of surgery. Future improvements should focus on both mechanical properties and biocompatibility. Nanoscaffold manufactured using electrospinning technology may provide great improvement in future practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Scaffolds in tissue engineering bone and cartilage
Hutmacher, D. W. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00121-6 · Cited by 4,994
Electrospinning of Collagen Nanofibers
Matthews, J. A., Wnek, G. E., Simpson, D. G., & Bowlin, G. L. (2002) · Biomacromolecules · doi:10.1021/bm015533u · Cited by 2,251
Age-related prevalence of rotator cuff tears in asymptomatic shoulders
Tempelhof, S., Rupp, S., & Seil, R. (1999) · Journal of Shoulder and Elbow Surgery · doi:10.1016/s1058-2746(99)90148-9 · Cited by 930
Rotator-cuff changes in asymptomatic adults. The effect of age, hand dominance and gender
Milgrom, C., Schaffler, M., Gilbert, S., & van Holsbeeck, M. (1995) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.77b2.7706351 · Cited by 852
Cell movements : from molecules to motility
Bray, D. (1992) · Cited by 674
Current Concepts Review - The Science of Reconstruction of the Anterior Cruciate Ligament*
FRANK, C. B., & JACKSON, D. W. (1997) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199710000-00014 · Cited by 622
Current concepts in the management of tendon disorders
Rees, J. D., Wilson, A. M., & Wolman, R. L. (2006) · Rheumatology · doi:10.1093/rheumatology/kel046 · Cited by 515
Badylak, S. F., Tullius, R., Kokini, K., Shelbourne, K. D., Klootwyk, T., Voytik, S. L., Kraine, M. R., & Simmons, C. (1995) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820290809 · Cited by 501
Enhancement of neurite outgrowth using nano-structured scaffolds coupled with laminin
Koh, H. S., Yong, T., Chan, C. K., & Ramakrishna, S. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.05.014 · Cited by 493
Encyclopedia of Medical Devices and Instrumentation
(2006) · Wiley eBooks · doi:10.1002/0471732877 · Cited by 481
IANNOTTI, J. P., CODSI, M. J., KWON, Y. W., DERWIN, K., CICCONE, J., & BREMS, J. J. (2006) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200606000-00010 · Cited by 479
Mechanical properties of the human achilles tendon
Wren, T. A. L., Yerby, S. A., Beaupré, G. S., & Carter, D. R. (2001) · Clinical Biomechanics · doi:10.1016/s0268-0033(00)00089-9 · Cited by 466
Zheng, M. H., Chen, J., Kirilak, Y., Willers, C., Xu, J., & Wood, D. (2005) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.30170 · Cited by 441
Self-citationEXTRACELLULAR MATRIX BIOSCAFFOLDS FOR ORTHOPAEDIC APPLICATIONS: A COMPARATIVE HISTOLOGIC STUDY
VALENTIN, J. E., BADYLAK, J. S., MCCABE, G. P., & BADYLAK, S. F. (2006) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200612000-00015 · Cited by 411
DERWIN, K. A., BAKER, A. R., SPRAGG, R. K., LEIGH, D. R., & IANNOTTI, J. P. (2006) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200612000-00014 · Cited by 352
Sclamberg, S. G., Tibone, J. E., Itamura, J. M., & Kasraeian, S. (2004) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2004.03.005 · Cited by 284
Dejardin, L. M., Arnoczky, S. P., Ewers, B. J., Haut, R. C., & Clarke, R. B. (2001) · The American Journal of Sports Medicine · doi:10.1177/03635465010290021001 · Cited by 276
Restore Orthobiologic Implant: Not Recommended for Augmentation of Rotator Cuff Repairs
Walton, J. R., Bowman, N. K., Khatib, Y., Linklater, J., & Murrell, G. A. C. (2007) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200704000-00013 · Cited by 239
Badhe, S. P., Lawrence, T. M., Smith, F. D., & Lunn, P. G. (2008) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2007.08.005 · Cited by 236
Nomura, E., Horiuchi, Y., & Kihara, M. (2000) · The Knee · doi:10.1016/s0968-0160(00)00072-7 · Cited by 213
Tendon Augmentation Grafts: Biomechanical Failure Loads and Failure Patterns
Barber, F. A., Herbert, M. A., & Coons, D. A. (2006) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2005.12.021 · Cited by 204
Malcarney, H. L., Bonar, F., & Murrell, G. A. C. (2005) · The American Journal of Sports Medicine · doi:10.1177/0363546504271500 · Cited by 204
Analysis of Retrieved Polymer Fiber Based Replacements for the ACL
Guidoin, M.-F., Marois, Y., Bejui, J., Poddevin, N., King, M. W., & Guidoin, R. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00114-9 · Cited by 197
Small intestinal submucosa: a substrate for in vitro cell growth
Badylak, S. F., Record, R., Lindberg, K., Hodde, J., & Park, K. (1998) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856298x00208 · Cited by 180
Nau, T., Lavoie, P., & Duval, N. (2002) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.84b3.12400 · Cited by 167
Gretzer, C., Emanuelsson, L., Liljensten, E., & Thomsen, P. (2006) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856206777346340 · Cited by 165
Brigido, S. A. (2006) · International Wound Journal · doi:10.1111/j.1742-481x.2006.00209.x · Cited by 143
Soler, J. A., Gidwani, S., & Curtis, M. J. (2007) · PubMed · Cited by 143
Synthesis and Properties of Degradable Poly(urethane urea)s To Be Used for Ligament Reconstructions
Gisselfält, K., Edberg, B., & Flodin, P. (2002) · Biomacromolecules · doi:10.1021/bm025535u · Cited by 130
Use of Graft Jacket as an Augmentation for Massive Rotator Cuff Tears
Burkhead, W. Z., Schiffern, S. C., & Krishnan, S. G. (2007) · Seminars in Arthroplasty JSES · doi:10.1053/j.sart.2006.11.017 · Cited by 127
Results from a degradable TMC joint Spacer (Artelon) compared with tendon arthroplasty
Nilsson, A., Liljensten, E., Bergström, C., & Sollerman, C. (2005) · The Journal Of Hand Surgery · doi:10.1016/j.jhsa.2004.12.001 · Cited by 125
Treatment of lateral epicondylitis.
Johnson, G. W., Cadwallader, K., Scheffel, S. B., & Epperly, T. D. (2007) · PubMed · Cited by 120
Surgical technique for xenograft (SIS) augmentation of rotator-cuff repairs
Metcalf, M. H., Savoie, F. H. “., & Kellum, B. (2002) · Operative Techniques in Orthopaedics · doi:10.1053/otor.2002.36298 · Cited by 112
Surgical Management of Traumatic Knee Dislocation
Ibrahim, S. A. R., Ahmad, F. H. F., Salah, M., Almisfer, A. K., Ghaffer, S. A., & Khirat, S. (2007) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/j.arthro.2007.08.007 · Cited by 112
10–16 year results of Leeds-Keio anterior cruciate ligament reconstruction
Murray, A. W., & Macnicol, M. F. (2003) · The Knee · doi:10.1016/s0968-0160(03)00076-0 · Cited by 105
Lavoie, P., Fletcher, J. A., & Duval, N. (2000) · The Knee · doi:10.1016/s0968-0160(00)00039-9 · Cited by 103
Adverse Effect of Porcine Collagen Interposition after Trapeziectomy a Comparative Study
BELCHER, H. J. C. R., & Žic, R. (2001) · Journal of Hand Surgery (European Volume) · doi:10.1054/jhsb.2001.0554 · Cited by 92
Holton, L. H., Kim, D., Silverman, R. P., Rodriguez, E. D., Singh, N., & Goldberg, N. H. (2005) · Journal of Long-Term Effects of Medical Implants · doi:10.1615/jlongtermeffmedimplants.v15.i5.70 · Cited by 88
Studies of polyurethane urea bands for ACL reconstruction
Liljensten, E., Gisselfält, K., Edberg, B., Bertilsson, H., Flodin, P., Nilsson, A., Lindahl, A. H., & Peterson, L. (2002) · Journal of Materials Science Materials in Medicine · doi:10.1023/a:1014380332762 · Cited by 85
Reconstruction of the anterior cruciate ligament: dynamic strain evaluation of the graft
Handl, M., Držík, M., Cerulli, G. G., Povýsil, C., Chlpík, J., Varga, F., Amler, E., & Trč, T. (2006) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-006-0175-x · Cited by 69
Brigido, S. A., Boc, S. F., & Lopez, R. C. (2004) · Orthopedics · doi:10.3928/0147-7447-20040102-14 · Cited by 66
Arthroscopic total rotator cuff replacement with an acellular human dermal allograft matrix
Dopirak, R. M., Bond, J. L., & Snyder, S. (2007) · International Journal of Shoulder Surgery · doi:10.4103/0973-6042.30673 · Cited by 64
GraftJacket Augmentation of Chronic Achilles Tendon Ruptures
Lee, M. S. (2004) · Orthopedics · doi:10.3928/0147-7447-20040102-15 · Cited by 62
Early results of the Leeds-Keio anterior cruciate ligament replacement
Macnicol, M. F., Penny, I., & Sheppard, L. (1991) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.73b3.1670431 · Cited by 62
Human in vivo cellular response to a cross-linked acellular collagen implant
Hammond, T. M., Chin-Aleong, J., Navsaria, H. A., & Williams, N. S. (2008) · British journal of surgery · doi:10.1002/bjs.5883 · Cited by 61
Long‐term results of the Leeds‐Keio anterior cruciate ligament reconstruction
Denti, M., Bigoni, M., Dodaro, G., Monteleone, M., & Arosio, A. (1995) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/bf01552378 · Cited by 48
Autograft and Leeds-Keio Reconstructions of the Ovine Anterior Cruciate Ligament
Schindhelm, K., Rogers, G. J., MILTHORPE, B. K., Hall, P. J., Howlett, C. R., Sekel, R., Goldberg, J. A., & Viglione, W. (1991) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199106000-00043 · Cited by 47
Muren, O., Dahlstedt, L. J., Brosjö, E., Dahlborn, M., & Dalén, N. (2005) · Acta Orthopaedica · doi:10.1080/00016470510030689 · Cited by 30
Ochi, M., Yamanaka, T., Sumen, Y., et al. (1993) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/s0749-8063(05)80312-3 · Cited by 24
Nomura, E., Inoue, M., & Sugiura, H. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.07.053 · Cited by 20
Matsumoto, H., Toyoda, T., Kawakubo, M., et al. (1999) · Journal of Orthopaedic Science · doi:10.1007/s007760050093 · Cited by 19
A new nonabsorbable adhesion barrier for myomectomy
PELOSI, M. A., & Pelosi, M. A. (2002) · The American Journal of Surgery · doi:10.1016/s0002-9610(02)01017-6 · Cited by 13
Comparative in vitro biomechanical evaluation of two soft tissue defect products
Johnson, W. M., Inamasu, J., Yantzer, B. K., Papangelou, C. G., & Guiot, B. H. (2007) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.30816 · Cited by 12
Cited by
Applications of synthetic polymers in clinical medicine
Maitz, M. F. (2015) · Biosurface and Biotribology · doi:10.1016/j.bsbt.2015.08.002 · Cited by 726
Kular, J. K., Basu, S., & Sharma, R. I. (2014) · Journal of Tissue Engineering · doi:10.1177/2041731414557112 · Cited by 559
How smart do biomaterials need to be? A translational science and clinical point of view
Holzapfel, B. M., Reichert, J. C., Schantz, J.-T., Gbureck, U., Rackwitz, L., Nöth, U., Jakob, F., Rudert, M., Groll, J., & Hutmacher, D. W. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.07.009 · Cited by 552
Therapeutic Strategies for Tendon Healing Based on Novel Biomaterials, Factors and Cells
Gross, G., & Hoffmann, A. (2013) · Pathobiology · doi:10.1159/000347059 · Cited by 467
Biomimetic Scaffolds for Tissue Engineering
Kim, T. G., Shin, H., & Lim, D. W. (2012) · Advanced Functional Materials · doi:10.1002/adfm.201103083 · Cited by 459
Metadata
- Authors
- Chen, J., Xu, J., Wang, A., & Zheng, M.
- Venue
- Expert Review of Medical Devices
- Publisher
- Informa UK Limited
- Published
- 2009-01
- Volume
- 6
- Issue
- 1
- Pages
- 61-73
- ISSN
- 1743-4440 (ISSN-L)
- 1745-2422
- OpenAlex
- W2111174701
- Cited by
- 342
- References
- 53
- FWCI
- 8.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.