Cardiac output monitoring in pediatric patients
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Cardiac output (CO) measurement is becoming increasingly important in the field of pediatric intensive care medicine and pediatric anesthesia. In the past few decades, various new technologies have been developed for the measurement of CO. Some of these methods are applicable to pediatric patients and some are already being used in children. The devices and methods have their advantages and limitations and, therefore, it is difficult for the clinician to decide which technique should be used. This article focuses on the currently available minimally invasive and noninvasive monitoring devices for CO measurement in children. A brief explanation of the technical aspects of each method and clinical use will be followed by the knowledge gained from infant animal and clinical pediatric studies. The goal of this article is to give an update of the various CO measurement technologies in children.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Cecconi, M., Rhodes, A., Poloniecki, J., Della Rocca, G., & Grounds, R. M. (2009) · Critical Care · doi:10.1186/cc7129 · Cited by 351
Clinicians’ abilities to estimate cardiac index in ventilated children and infants
Tibby, S. M., Hatherill, M., Marsh, M. J., & Murdoch, I. A. (1997) · Archives of Disease in Childhood · doi:10.1136/adc.77.6.516 · Cited by 224
Chew, M. S., & Poelaert, J. (2003) · Intensive Care Medicine · doi:10.1007/s00134-003-1967-9 · Cited by 151
Cited by
Singh, Y., Villaescusa, J. U., da Cruz, E. M., Tibby, S. M., Bottari, G., Saxena, R., Guillén, M., Herce, J. L., Di Nardo, M., Cecchetti, C., et al. (2020) · Critical Care · doi:10.1186/s13054-020-03326-2 · Cited by 86
Self-citationNeonatal hemodynamics: Monitoring, data acquisition and analysis
Soleymani, S., Borzage, M., Noori, S., & Seri, I. (2012) · Expert Review of Medical Devices · doi:10.1586/erd.12.32 · Cited by 23
Cardiac output monitoring in paediatric cardiac surgery: A review
Woodman, H. M., Lee, C., Ahmed, A. N., Malik, B. A., Mellor, S., Brown, L. J., Gentle, L., & Harky, A. (2021) · Cardiology in the Young · doi:10.1017/s1047951120004680 · Cited by 7
Metadata
- Authors
- Nusmeier, A., van der Hoeven, J. G., & Lemson, J.
- Venue
- Expert Review of Medical Devices
- Publisher
- Informa UK Limited
- Published
- 2010-07
- Volume
- 7
- Issue
- 4
- Pages
- 503-517
- ISSN
- 1743-4440 (ISSN-L)
- 1745-2422
- OpenAlex
- W2137579922
- Cited by
- 40
- References
- 4
- FWCI
- 4.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.