CONDENSATE RETENTION AND DYNAMIC DRAINAGE FROM THE AIR-SIDE SURFACE OF AUTOMOTIVE-STYLE HEAT EXCHANGER
Abstract
In this paper we describe a new method for dip testing to characterize the condensate drainage behavior of heat exchangers, and we present drainage results for heat exchangers typical to those used in the automotive industry. We compare the results from dip testing to wind tunnel experiments for the same heat exchangers and find dip testing can serve as a powerful tool for assessing the condensate retention behavior. The coils retaining the most and least condensate in a steady state wind tunnel test, likewise held the most and least in a dip test. It is found that the offset-strip fins of this study hold roughly 60% less water per unit area than louvered-fin specimens.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Water retention can alternatively be computed without experimental data from static mechanical or dynamic mechanical models.
“Alternatively, the water retention can be computed without experimental data from static mechanical [37] or dynamic mechanical [38] models with the developments of [39-41].”
From Model for cyclic frosting and defrosting of flat tube heat exchangers: Theoretical analysis and experimental validation (2023) · cites this paper as [41]
Citations
Cites
Water condensate retention and “wet” fin performance in automotive evaporators
Zhang, C. A., Hu, H., Jacobi, A. M., & Kaiser, J. M. (2001) · SAE Technical Paper Series · doi:10.4271/2001-01-1252 · Cited by 3
Self-citation
Flagged first, then by citations
Research works printed but not linked: 6
- Chiou, C. B., Wang C.C., Chang, Y. J., and Lu, D. C., 1994, 'Experimental Study of Heat Transfer and Flow Friction Characteristics of Automotive Evaporators,' ASHRAE Transactions, Vol. 100 (2), pp. 575-582.
- Kline, S.J. and McClintock, F.A., 1953, 'Describing Experimental Uncertainties in Single Sample Experiments,' Mechanical Engineering, Vol. 75 pp. 3-8.
- McLaughlin, 1999, 'The Effect of Condensate on the Air Side Performance of Louver fin Automotive Evaporators,' MS thesis, Department of Mechanical Engineering, The Pennsylvania State University. · DOI
- McLaughlin, W.J. and Webb, R.L., 2000, 'Condensate Drainage and Retention in Louver Fin Automotive Evaporators,' Proceedings of the SAE International Congress, Detroit, MI, March 3-6. · DOI · Paper page
- Osada, H., Aoki, H., Ohara, T., and Kuroyanagi, I., 1999, 'Experimental Analysis for Enhancing Automotive Evaporator Fin Performance,' Proceedings of the International Conference on Compact Heat Exchangers and Enhancement Technology for the Process Industries, R.K. Shah, Ed., pp. 439-445.
- Osada, H., Aoki, H., Ohara, T., and Kuroyanagi, I., 2001, 'Research on Corrugated Multi-Louvered Fins under Dehumidification,' Heat Transfer - Asian Research, Vol. 30, pp. 383-393. · DOI · Paper page
Cited by
Sorted by citations
Flat tube heat exchangers: Experimental analysis of frosting and water retention
Westhaeuser, J., Brauchle, L., Albrecht, J.-C., Tegethoff, W., Lemke, N., & Koehler, J. (2023) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2022.119319 · Cited by 24
Westhaeuser, J., Schulze, C., Albrecht, J.-C., Tegethoff, W., Lemke, N., & Koehler, J. (2023) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2023.120140 · Cited by 12
Metadata
- Authors
- Kaiser, J., Zhong, Y., Jacobi, A. M., Zhang, C., & Hu, H.
- Venue
- Proceeding of Compact Heat Exchangers and Enhancement Technology for the Process Industries - 2003
- Publisher
- Begellhouse
- Published
- 2023
- Pages
- 361-366
- OpenAlex
- W4365384878
- Cited by
- 3
- References
- 1
- Citations by year
- 2023: 1
- FWCI
- 0.88
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- International Conference on Compact Heat Exchangers and Enhancement Technology for the Process Industries (publishedVersion)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
- Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Boiling Studies
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Keywords
- condensate drainage, automotive heat exchangers, offset strip fins, louver fins, wind tunnel testing
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review