Cited by 3Heat Transfer and OptimizationHeat Transfer and Boiling StudiesRefrigeration and Air Conditioning Technologies

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

CONDENSATE RETENTION AND DYNAMIC DRAINAGE FROM THE AIR-SIDE SURFACE OF AUTOMOTIVE-STYLE HEAT EXCHANGER

Kaiser, James, Zhong, Yongfang, Jacobi, Anthony M., Zhang, Chao, Hu, Huey·2023·Proceeding of Compact Heat Exchangers and Enhancement Technology for the Process Industries - 2003

Abstract

In this paper we describe a new method for dip testing to characterize the condensate drainage behavior of heat exchangers, and we present drainage results for heat exchangers typical to those used in the automotive industry. We compare the results from dip testing to wind tunnel experiments for the same heat exchangers and find dip testing can serve as a powerful tool for assessing the condensate retention behavior. The coils retaining the most and least condensate in a steady state wind tunnel test, likewise held the most and least in a dip test. It is found that the offset-strip fins of this study hold roughly 60% less water per unit area than louvered-fin specimens.

Overview

Integrity signals

Registry

Crossref · 10.1615/978-1-56700-195-2.480

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Flagged first, then by citations

Research works printed but not linked: 6

  1. Chiou, C. B., Wang C.C., Chang, Y. J., and Lu, D. C., 1994, 'Experimental Study of Heat Transfer and Flow Friction Characteristics of Automotive Evaporators,' ASHRAE Transactions, Vol. 100 (2), pp. 575-582.
  2. Kline, S.J. and McClintock, F.A., 1953, 'Describing Experimental Uncertainties in Single Sample Experiments,' Mechanical Engineering, Vol. 75 pp. 3-8.
  3. McLaughlin, 1999, 'The Effect of Condensate on the Air Side Performance of Louver fin Automotive Evaporators,' MS thesis, Department of Mechanical Engineering, The Pennsylvania State University. · DOI
  4. McLaughlin, W.J. and Webb, R.L., 2000, 'Condensate Drainage and Retention in Louver Fin Automotive Evaporators,' Proceedings of the SAE International Congress, Detroit, MI, March 3-6. · DOI · Paper page
  5. Osada, H., Aoki, H., Ohara, T., and Kuroyanagi, I., 1999, 'Experimental Analysis for Enhancing Automotive Evaporator Fin Performance,' Proceedings of the International Conference on Compact Heat Exchangers and Enhancement Technology for the Process Industries, R.K. Shah, Ed., pp. 439-445.
  6. Osada, H., Aoki, H., Ohara, T., and Kuroyanagi, I., 2001, 'Research on Corrugated Multi-Louvered Fins under Dehumidification,' Heat Transfer - Asian Research, Vol. 30, pp. 383-393. · DOI · Paper page

Cited by

Sorted by citations

Metadata

Authors
Kaiser, J., Zhong, Y., Jacobi, A. M., Zhang, C., & Hu, H.
Venue
Proceeding of Compact Heat Exchangers and Enhancement Technology for the Process Industries - 2003
Publisher
Begellhouse
Published
2023
Pages
361-366
OpenAlex
W4365384878
Cited by
3
References
1
Citations by year
2023: 1
FWCI
0.88
Type
conference paper
Language
en
Open access
closed
Locations
International Conference on Compact Heat Exchangers and Enhancement Technology for the Process Industries (publishedVersion)
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Optimization
  • Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Boiling Studies
  • Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
Keywords
condensate drainage, automotive heat exchangers, offset strip fins, louver fins, wind tunnel testing

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review