Ferric Gluconate Is Highly Efficacious in Anemic Hemodialysis Patients with High Serum Ferritin and Low Transferrin Saturation: Results of the Dialysis Patients’ Response to IV Iron with Elevated Ferritin (DRIVE) Study
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Few data exist to guide treatment of anemic hemodialysis patients with high ferritin and low transferrin saturation (TSAT). The Dialysis Patients' Response to IV Iron with Elevated Ferritin (DRIVE) trial was designed to evaluate the efficacy of intravenous ferric gluconate in such patients. Inclusion criteria were hemoglobin or=225 IU/kg per wk or >or=22,500 IU/wk. Patients with known infections or recent significant blood loss were excluded. Participants (n=134) were randomly assigned to no iron (control) or to ferric gluconate 125 mg intravenously with eight consecutive hemodialysis sessions (intravenous iron). At randomization, epoetin was increased 25% in both groups; further dosage changes were prohibited. At 6 wk, hemoglobin increased significantly more (P=0.028) in the intravenous iron group (1.6 +/- 1.3 g/dl) than in the control group (1.1 +/- 1.4 g/dl). Hemoglobin response occurred faster (P=0.035) and more patients responded after intravenous iron than in the control group (P=0.041). Ferritin 800 ng/ml had no relationship to the magnitude or likelihood of responsiveness to intravenous iron relative to the control group. Similarly, the superiority of intravenous iron compared with no iron was similar whether baseline TSAT was above or below the study median of 19%. Ferritin decreased in control subjects (-174 +/- 225 ng/ml) and increased after intravenous iron (173 +/- 272 ng/ml; P<0.001). Intravenous iron resulted in a greater increase in TSAT than in control subjects (7.5 +/- 7.4 versus 1.8 +/- 5.2%; P<0.001). Reticulocyte hemoglobin content fell only in control subjects, suggesting worsening iron deficiency. Administration of ferric gluconate (125 mg for eight treatments) is superior to no iron therapy in anemic dialysis patients receiving adequate epoetin dosages and have a ferritin 500 to 1200 ng/ml and TSAT
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Acute-Phase Proteins and Other Systemic Responses to Inflammation
Gabay, C., & Kushner, I. (1999) · New England Journal of Medicine · doi:10.1056/nejm199902113400607 · Cited by 6,734 · cited 1×
“First, ferritin is an acute-phase reactant, increasing in response to acute and chronic inflammation (17,18).”
BackgroundWeiss, G., & Goodnough, L. T. (2005) · New England Journal of Medicine · doi:10.1056/nejmra041809 · Cited by 3,800
Correction of anemia with epoetin alfa in chronic kidney disease
Singh, A. K., Szczech, L., Tang, K. L., Barnhart, H., Sapp, S., Wolfson, M., & Reddan, D. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa065485 · Cited by 2,762
(2006) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2006.03.010 · Cited by 829
Noninvasive prediction of fibrosis in C282Y homozygous hemochromatosis
Guyader, D., Jacquelinet, C., Moirand, R., Turlin, B., Mendler, M. H., Chaperon, J., David, V., Brissot, P., Adams, P., & Deugnier, Y. (1998) · Gastroenterology · doi:10.1016/s0016-5085(98)70265-3 · Cited by 342
Time-Dependent Associations between Iron and Mortality in Hemodialysis Patients
Kalantar-Zadeh, K., Regidor, D. L., McAllister, C. J., Michael, B., & Warnock, D. G. (2005) · Journal of the American Society of Nephrology · doi:10.1681/asn.2005040423 · Cited by 285
Adams, P. C., Deugnier, Y., Moirand, R., & Brissot, P. (1997) · Hepatology · doi:10.1002/hep.510250130 · Cited by 241
Diagnosis and Management of Hemochromatosis
Tavill, A. S. (2001) · Hepatology · doi:10.1053/jhep.2001.24783 · Cited by 226
2005 Annual Report: ESRD Clinical Performance Measures Project
Kinney, R. (2006) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2006.07.015 · Cited by 211
Tessitore, N., Solero, G. P., Lippi, G., Bassi, A., Faccini, G. B., Bedogna, V., Gammaro, L., Brocco, G., Restivo, G., Bernich, P., et al. (2001) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/16.7.1416 · Cited by 210
Cited by
Ganz, T., & Nemeth, E. (2012) · Biochimica et Biophysica Acta (BBA) - Molecular Cell Research · doi:10.1016/j.bbamcr.2012.01.014 · Cited by 1,282
(2007) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2007.06.008 · Cited by 727
Macdougall, I. C., Bircher, A. J., Eckardt, K.-U., Obrador, G. T., Pollock, C. A., Stenvinkel, P., Swinkels, D. W., Wanner, C., Weiss, G., Chertow, G. M., et al. (2016) · Kidney International · doi:10.1016/j.kint.2015.10.002 · Cited by 482
Self-citationLocatelli, F., Bárány, P., Covic, A., De Francisco, A., Del Vecchio, L., Goldsmith, D., Hörl, W., London, G., Vanholder, R., Van Biesen, W., et al. (2013) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gft033 · Cited by 471
Hepcidin and disorders of iron metabolism
Ganz, T., & Nemeth, E. (2011) · Annual Review of Medicine · doi:10.1146/annurev-med-050109-142444 · Cited by 466
The Safety of Intravenous Iron Preparations
Avni, T., Bieber, A., Grossman, A., Green, H., Leibovici, L., & Gafter-Gvili, A. (2015) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2014.10.007 · Cited by 441
Guidelines for the management of chronic kidney disease
Levin, A., Hemmelgarn, B., Culleton, B., Tobe, S., McFarlane, P., Ruzicka, M., Burns, K., Manns, B., White, C., Madore, F., et al. (2008) · Canadian Medical Association Journal · doi:10.1503/cmaj.080351 · Cited by 420
KDIGO clinical practice guidelines for bisphosphonate treatment in chronic kidney disease
Woo, K. T., & Chan, C. M. (2011) · Kidney International · doi:10.1038/ki.2011.202 · Cited by 412
Detection, evaluation, and management of iron-restricted erythropoiesis
Goodnough, L. T., Nemeth, E., & Ganz, T. (2010) · Blood · doi:10.1182/blood-2010-05-286260 · Cited by 410
Guideline for the laboratory diagnosis of functional iron deficiency
Thomas, D. W., Hinchliffe, R. F., Briggs, C., Macdougall, I. C., Littlewood, T., Cavill, I., & British Committee for Standards in Haematology (2013) · British Journal of Haematology · doi:10.1111/bjh.12311 · Cited by 406
Litton, E., Xiao, J., & Ho, K. M. (2013) · BMJ · doi:10.1136/bmj.f4822 · Cited by 394
Iron Sequestration and Anemia of Inflammation
Ganz, T., & Nemeth, E. (2009) · Seminars in Hematology · doi:10.1053/j.seminhematol.2009.06.001 · Cited by 361
Iron Deficiency in Chronic Kidney Disease: Updates on Pathophysiology, Diagnosis, and Treatment
Batchelor, E. K., Kapitsinou, P., Pergola, P. E., Kovesdy, C. P., & Jalal, D. I. (2020) · Journal of the American Society of Nephrology · doi:10.1681/asn.2019020213 · Cited by 334
Clinical Use of Intravenous Iron: Administration, Efficacy, and Safety
Auerbach, M., & Ballard, H. (2010) · Hematology · doi:10.1182/asheducation-2010.1.338 · Cited by 310
Renal association clinical practice guideline on Anaemia of Chronic Kidney Disease
Mikhail, A., Brown, C., Williams, J. A., Mathrani, V., Shrivastava, R., Evans, J., Isaac, H., & Bhandari, S. (2017) · BMC Nephrology · doi:10.1186/s12882-017-0688-1 · Cited by 299
KDOQI US Commentary on the 2012 KDIGO Clinical Practice Guideline for Anemia in CKD
Kliger, A. S., Foley, R. N., Goldfarb, D. S., Goldstein, S. L., Johansen, K., Singh, A., & Szczech, L. (2013) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2013.06.008 · Cited by 270
Self-citationIron Deficiency Anemia in Chronic Kidney Disease
Gafter-Gvili, A., Schechter, A., & Rozen-Zvi, B. (2019) · Acta Haematologica · doi:10.1159/000496492 · Cited by 265
2015 Japanese Society for Dialysis Therapy: Guidelines for Renal Anemia in Chronic Kidney Disease
Yamamoto, H., Nishi, S., Tomo, T., Masakane, I., Saito, K., Nangaku, M., Hattori, M., Suzuki, T., Morita, S., Ashida, A., et al. (2017) · Renal Replacement Therapy · doi:10.1186/s41100-017-0114-y · Cited by 252
“A previous study reported that iron administration improves anemia, even among patients with high serum ferritin levels [125].”
BackgroundLocatelli, F., Covic, A., Eckardt, K.-U., Wiecek, A., Vanholder, R., & on behalf of the ERA-EDTA ERBP Advisory Board (2008) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfn653 · Cited by 218
“No key study has been published since the publication of the 2006 KDOQI guidelines, but it is interesting to note the results of the Dialysis Patients’ Response to IV Iron with Elevated Ferritin (DRIVE) trial [20], which evaluated the efficacy of intravenous ferric gluconate in 134 patients with high ferritin (500–120…”
BackgroundPredictors of Hyporesponsiveness to Erythropoiesis-Stimulating Agents in Hemodialysis Patients
Kalantar-Zadeh, K., Lee, G. H., Miller, J. E., Streja, E., Jing, J., Robertson, J. A., & Kovesdy, C. P. (2009) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2008.12.040 · Cited by 193
“Although debates bout withholding IV iron administration in HD atients with a ferritin level greater than 500 g/mL continue,(18,19) a recent randomized conrolled trial showed that in ESA-hyporesponsive nd anemic HD patients with ferritin level ranges f 500 to 1,200 ng/mL, administration of 1 g of ron gluconate in addi…”
BackgroundFerumoxytol as an Intravenous Iron Replacement Therapy in Hemodialysis Patients
Provenzano, R., Schiller, B., Rao, M., Coyne, D., Brenner, L., & Pereira, B. J. G. (2009) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.02840608 · Cited by 187
Self-citationBailie, G. R., Larkina, M., Goodkin, D. A., Li, Y., Pisoni, R. L., Bieber, B., Mason, N., Tong, L., Locatelli, F., Marshall, M. R., et al. (2015) · Kidney International · doi:10.1038/ki.2014.275 · Cited by 186
Sun, C. C., Vaja, V., Babitt, J. L., & Lin, H. Y. (2012) · American Journal of Hematology · doi:10.1002/ajh.23110 · Cited by 185
“The Dialysis Patient’s Response to IV Iron and with Elevated Ferritin study revealed that anemic hemodialysis patients receiving IV ferric gluconate, and ESAs had a faster and more robust response in hemoglobin levels and reticulocyte hemoglobin levels compared to those receiving ESAs alone [87].”
BackgroundFerric Gluconate Reduces Epoetin Requirements in Hemodialysis Patients with Elevated Ferritin
Kapoian, T., O'Mara, N. B., Singh, A. K., Moran, J., Rizkala, A. R., Geronemus, R., Kopelman, R. C., Dahl, N. V., & Coyne, D. W. (2008) · Journal of the American Society of Nephrology · doi:10.1681/asn.2007050606 · Cited by 181
Self-citationErythropoiesis‐stimulating agent hyporesponsiveness (Review Article)
JOHNSON, D. W., POLLOCK, C. A., & MACDOUGALL, I. C. (2007) · Nephrology · doi:10.1111/j.1440-1797.2007.00810.x · Cited by 177
“recently published the results of the Dialysis patients’ Response to IV iron with Elevated ferritin (DRIVE) trial, in which 134 patients with haemoglobin 2110 g/L, serum ferritin 500–1200 ng/mL, TSAT 225% and epoetin dosage 3225 IU/kg per week or 322 500 IU per week were randomly assigned to receive either no iron (co…”
Kuragano, T., Matsumura, O., Matsuda, A., Hara, T., Kiyomoto, H., Murata, T., Kitamura, K., Fujimoto, S., Hase, H., Joki, N., et al. (2014) · Kidney International · doi:10.1038/ki.2014.114 · Cited by 177
“of the hemoglobin fluctuation pattern: (1) within the target hemoglobin range of 10–11 g/dl (target-hemoglobin group); (2) consistently below the target hemoglobin range (low-hemoglobin group); (3) consistently above the target hemoglobin range (highhemoglobin group); (4) low-amplitude fluctuation around the upper lim…”
BackgroundFerumoxytol for treatment of iron deficiency anemia in patients with chronic kidney disease
Coyne, D. W. (2009) · Expert Opinion on Pharmacotherapy · doi:10.1517/14656560903224998 · Cited by 95
“Use of erythropoiesis-stimulating agents (ESA) such as epoetin to treat anemia in patients with CKD leads to greater demand on remaining iron stores and to progressive iron deficiency and inefficient erythropoiesis [3,4].”
BackgroundIron and infection in hemodialysis patients
Ishida, J. H., & Johansen, K. L. (2014) · Seminars in Dialysis · doi:10.1111/sdi.12168 · Cited by 65
Management of anemia of inflammation in the elderly
Macciò, A., & Madeddu, C. (2012) · Anemia · doi:10.1155/2012/563251 · Cited by 60
“iron has been demonstrated to improve hemoglobin response to ESAs both in cancer [96] as well as in dialysis patients [97].”
BackgroundSonnweber, T., Theurl, I., Seifert, M., Schroll, A., Eder, S., Mayer, G., & Weiss, G. (2011) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfq483 · Cited by 55
“Iron deficiency in ESRD patients is treated with intravenous iron [15].”
BackgroundWhat is so bad about a hemoglobin level of 12 to 13 g/dL for chronic kidney disease patients anyway?
Besarab, A., Frinak, S., & Yee, J. (2009) · Advances in Chronic Kidney Disease · doi:10.1053/j.ackd.2008.12.007 · Cited by 34
Metadata
- Authors
- Coyne, D. W., Kapoian, T., Suki, W., Singh, A. K., Moran, J. E., Dahl, N. V., & Rizkala, A. R.
- Venue
- Journal of the American Society of Nephrology
- Published
- 2007-03
- Volume
- 18
- Issue
- 3
- Pages
- 975-984
- ISSN
- 1046-6673 (ISSN-L)
- OpenAlex
- W2144758554
- Cited by
- 391
- References
- 25
- FWCI
- 22.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.