Selecting the Appropriate Continuous Glucose Monitoring System – a Practical Approach
Open accessThe DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Two types of continuous glucose monitoring (CGM) systems are currently available for daily diabetes self-management: real-time CGM and intermittently scanned CGM. Both approaches provide continuous measurement of glucose concentrations in the interstitial fluid; however, each has its own unique features that can impact their usefulness and acceptability within specific patient groups. This article explores the strengths and limitations of each approach and provides guidance to healthcare professionals in selecting the CGM type that is most appropriate to the individual needs of their patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
International consensus on use of continuous glucose monitoring
Danne, T., Nimri, R., Battelino, T., Bergenstal, R. M., Close, K. L., DeVries, J. H., Garg, S., Heinemann, L., Hirsch, I., Amiel, S. A., et al. (2017) · Diabetes Care · doi:10.2337/dc17-1600 · Cited by 2,069 · cited 1×
“Such parameters are time in hypoglycaemia, target and hyperglycaemia ranges, frequency of hypoglycaemic events (for at least 20 minutes) and glycaemic variability (coefficient of variation [CV]), as recently proposed by several international medical organisations and others.(3,11,12) CGM is required to perform these c…”
BackgroundSelf-citationBeck, R. W., Riddlesworth, T., Ruedy, K., Ahmann, A., Bergenstal, R., Haller, S., Kollman, C., Kruger, D., McGill, J. B., Polonsky, W., et al. (2017) · JAMA · doi:10.1001/jama.2016.19975 · Cited by 1,185
Bolinder, J., Antuna, R., Geelhoed-Duijvestijn, P., Kröger, J., & Weitgasser, R. (2016) · The Lancet · doi:10.1016/s0140-6736(16)31535-5 · Cited by 893
Feig, D. S., Donovan, L. E., Corcoy, R., Murphy, K. E., Amiel, S. A., Hunt, K. F., Asztalos, E., Barrett, J. F. R., Sanchez, J. J., de Leiva, A., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)32400-5 · Cited by 803
Lind, M., Polonsky, W., Hirsch, I. B., Heise, T., Bolinder, J., Dahlqvist, S., Schwarz, E., Ólafsdóttir, A. F., Frid, A., Wedel, H., et al. (2017) · JAMA · doi:10.1001/jama.2016.19976 · Cited by 705
Beck, R. W., Riddlesworth, T. D., Ruedy, K., Ahmann, A., Haller, S., Kruger, D., McGill, J. B., Polonsky, W., Price, D., Aronoff, S., et al. (2017) · Annals of Internal Medicine · doi:10.7326/m16-2855 · Cited by 635
Haak, T., Hanaire, H., Ajjan, R., Hermanns, N., Riveline, J.-P., & Rayman, G. (2017) · Diabetes Therapy · doi:10.1007/s13300-016-0223-6 · Cited by 623 · cited 3×
“This may explain why the current Libre studies showed no reductions in HbA1c.36,37 Apart from the clinical implications of CGM inaccuracy, there is the potential impact on patient persistence in using their devices.”
ResultEffects of hemoglobin variants and chemically modified derivatives on assays for glycohemoglobin
Bry, L., Chen, P. C., & Sacks, D. B. (2001) · Clinical Chemistry · doi:10.1093/clinchem/47.2.153 · Cited by 523 · cited 1×
“We also know that HbA1c can be an unreliable measure during pregnancy(7) and in patients with iron deficiencies,(8) anemia(9) and haemoglobinopathies.(10) Importantly, HbA1c does not provide guidance for daily adjustments in therapy.”
BackgroundMiller, K. M., Beck, R. W., Bergenstal, R. M., Goland, R. S., Haller, M. J., McGill, J. B., Rodriguez, H., Simmons, J. H., Hirsch, I. B., & for the T1D Exchange Clinic Network (2013) · Diabetes Care · doi:10.2337/dc12-1770 · Cited by 505
Polonsky, W. H., Fisher, L., Schikman, C. H., Hinnen, D. A., Parkin, C. G., Jelsovsky, Z., Petersen, B., Schweitzer, M., & Wagner, R. S. (2011) · Diabetes Care · doi:10.2337/dc10-1732 · Cited by 429
Self-citationAgiostratidou, G., Anhalt, H., Ball, D., Blonde, L., Gourgari, E., Harriman, K. N., Kowalski, A. J., Madden, P., McAuliffe-Fogarty, A. H., McElwee-Malloy, M., et al. (2017) · Diabetes Care · doi:10.2337/dc17-1624 · Cited by 397
van Beers, C. A. J., DeVries, J. H., Kleijer, S. J., Smits, M. M., Geelhoed-Duijvestijn, P. H., Kramer, M. H. H., Diamant, M., Snoek, F. J., & Serné, E. H. (2016) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(16)30193-0 · Cited by 386
Polonsky, W. H., Hessler, D., Ruedy, K. J., & Beck, R. W. (2017) · Diabetes Care · doi:10.2337/dc17-0133 · Cited by 346
HbA1c levels are significantly lower in early and late pregnancy
Nielsen, L. R., Ekbom, P., Damm, P., Glümer, C., Frandsen, M. M., Jensen, D. M., & Mathiesen, E. R. (2004) · Diabetes Care · doi:10.2337/diacare.27.5.1200 · Cited by 331
Aleppo, G., Ruedy, K. J., Riddlesworth, T. D., Kruger, D. F., Peters, A. L., Hirsch, I., Bergenstal, R. M., Toschi, E., Ahmann, A. J., Shah, V. N., et al. (2017) · Diabetes Care · doi:10.2337/dc16-2482 · Cited by 329
Reddy, M., Jugnee, N., El Laboudi, A., Spanudakis, E., Anantharaja, S., & Oliver, N. (2018) · Diabetic Medicine · doi:10.1111/dme.13561 · Cited by 245 · cited 2×
“Importantly, in the recent I Hart CGM study, Reddy and colleagues showed that use of rtCGM more effectively reduces time spent in hypoglycaemia than isCGM among T1D patients with impaired awareness of hypoglycaemia.(35)”
MethodResultYoo, H. J., An, H. G., Park, S. Y., Ryu, O. H., Kim, H. Y., Seo, J. A., Hong, E. G., Shin, D. H., Kim, Y. H., Kim, S. G., et al. (2008) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2008.06.015 · Cited by 244 · cited 1×
“The benefits of rtCGM use have also been shown in patients with T2D treated with MDI therapy,(31) in older T1D and T2D MDI-treated patients(32) and in T2D who are managed with intensive insulin treatment.(33,34) Importantly, in the recent I Hart CGM study, Reddy and colleagues showed that use of rtCGM more effectively…”
BackgroundFonseca, V. A., Grunberger, G., Anhalt, H., Bailey, T. S., Blevins, T., Garg, S. K., Handelsman, Y., Hirsch, I. B., Orzeck, E. A., Roberts, V. L., et al. (2016) · Endocrine Practice · doi:10.4158/ep161392.cs · Cited by 195
Iron-deficiency anemia, non-iron-deficiency anemia and HbA1c among adults in the US
FORD, E. S., COWIE, C. C., LI, C., HANDELSMAN, Y., & BLOOMGARDEN, Z. T. (2011) · Journal of Diabetes · doi:10.1111/j.1753-0407.2010.00100.x · Cited by 165
Cox, D. J., Kovatchev, B. P., Julian, D. M., Gonder-Frederick, L. A., Polonsky, W. H., Schlundt, D. G., & Clarke, W. L. (1994) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.79.6.7989471 · Cited by 137 · cited 1×
“Nor does it reflect the occurrence or degree of daily glucose variability, which has been shown to be a consistent predictor of hypoglycaemia.(5,6) We also know that HbA1c can be an unreliable measure during pregnancy(7) and in patients with iron deficiencies,(8) anemia(9) and haemoglobinopathies.”
BackgroundFranciosi, M., Lucisano, G., Pellegrini, F., Cantarello, A., Consoli, A., Cucco, L., Ghidelli, R., Sartore, G., Sciangula, L., Nicolucci, A., et al. (2011) · Diabetic Medicine · doi:10.1111/j.1464-5491.2011.03268.x · Cited by 137
Improving the Clinical Value and Utility of CGM Systems: Issues and Recommendations
Petrie, J. R., Peters, A. L., Bergenstal, R. M., Holl, R. W., Fleming, G. A., & Heinemann, L. (2017) · Diabetes Care · doi:10.2337/dci17-0043 · Cited by 135
Šoupal, J., Petruželková, L., Flekač, M., Pelcl, T., Matoulek, M., Daňková, M., Škrha, J., Svačina, Š., & Prázný, M. (2016) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.0171 · Cited by 126
Riddlesworth, T., Price, D., Cohen, N., & Beck, R. W. (2017) · Diabetes Therapy · doi:10.1007/s13300-017-0281-4 · Cited by 65
Kempf, K., Kruse, J., & Martin, S. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0116 · Cited by 48
Cited by
Grunberger, G., Sherr, J., Allende, M., Blevins, T., Bode, B., Handelsman, Y., Hellman, R., Lajara, R., Roberts, V. L., Rodbard, D., et al. (2021) · Endocrine Practice · doi:10.1016/j.eprac.2021.04.008 · Cited by 288
Teo, E., Hassan, N., Tam, W., & Koh, S. (2022) · Diabetologia · doi:10.1007/s00125-021-05648-4 · Cited by 186
Reference Guide for Integrating Continuous Glucose Monitoring Into Clinical Practice
Kruger, D. F., Edelman, S. V., Hinnen, D. A., & Parkin, C. G. (2019) · The Diabetes Educator · doi:10.1177/0145721718818066 · Cited by 55
Self-citationWang, Y., Zou, C., Na, H., Zeng, W., & Li, X. (2022) · Computational and Mathematical Methods in Medicine · doi:10.1155/2022/2851572 · Cited by 12
“HbA1c is the gold standard for assessing glycemic control and an alternative indicator [25] for evaluating the risk of long-term diabetes complications.”
Background
Metadata
- Authors
- Adolfsson, P., Parkin, C. G., Thomas, A., & Krinelke, L. G.
- Venue
- European Endocrinology
- Publisher
- Touch Medical Media, Ltd.
- Published
- 2018
- Volume
- 14
- Issue
- 1
- Pages
- 24
- ISSN
- 1758-3772 (ISSN-L)
- OpenAlex
- W2800257049
- Cited by
- 63
- References
- 25
- FWCI
- 6.65
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.