Effect of Different Glucose Monitoring Methods on Bold Glucose Control: A Systematic Review and Meta-Analysis

Open access
Wang, Yeling, Zou, Congcong, Na, Han, Zeng, Weixin, Li, Xiaoyan·2022·Computational and Mathematical Methods in Medicine

Abstract

Objective. To evaluate the effectiveness of different glucose monitoring methods on blood glucose control and the incidence of adverse events among patients with type 1 diabetes mellitus. Methods. Using the method of literature review, the databases PubMed, Cochrane, and Embase were retrieved to obtain relevant research literature, and the selected studies were analyzed and evaluated. This study used Cochrane software RevMan5.4 to statistically analyze all the data. Results. A total of 15 studies were included in this study, including 10 randomized controlled trials and 5 crossover design trials, with a total of 2071 patients. Meta-analysis results showed that continuous blood glucose monitoring (CGM) could significantly reduce the HbA1c level of patients, weighted mean difference WMD = − 2.69 , 95% confidence interval (CI) (-4.25, -1.14), and P < 0.001 compared with self-monitoring of blood glucose (SMBG). Meanwhile, the incidence of severe hypoglycemia in the CGM group was significantly decreased, risk ratio RR = 0.52 , 95% CI 0.35-0.77, and P = 0.001 . However, there was no statistical difference in the probability of diabetic ketoacidosis between CGM and SMBG groups, RR = 1.34 , 95% CI 0.57-3.15, and P = 0.5 . Conclusion. Continuous blood glucose monitoring is associated with lower blood glucose levels than the traditional blood glucose self-test method.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1155/2022/2851572

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • CGM and closed-loop insulin delivery systems have been shown to significantly improve TIR, reduce HbA1c levels, and decrease TBR/TAR, thereby enhancing glycemic stability in both Type 1 and T2D patients.

    “Regarding glycemic control, CGM and closed‐loop insulin delivery systems (AID, CLS, and artificial pancreas) have been shown to significantly improve TIR, reduce HbA1c levels, and decrease TBR/time above range (TAR), thereby enhancing glycemic stability in both Type 1 and T2D patients [24, 25, 35, 36].”

    From Effectiveness of Wearable Devices for Diabetes Management: An Overview of Systematic Reviews and Meta‐Analyses (2026) · cites this paper as [24]

    The Results (section 3.3; page unavailable) report significantly lower HbA1c with CGM than with self-monitoring, and section 3.2 identifies the participants as having type 1 diabetes. The paper does not report effects on TIR, TBR or TAR, assess closed-loop insulin delivery, or study patients with type 2 diabetes; its other reported benefit is fewer severe hypoglycemic events. (LLM, conf=0.90)

    Experimental — accuracy not yet measured
  • Substantial heterogeneity, inadequate sample sizes, and publication bias were primary reasons for downgrading evidence.

    “primarily due to: ? substantial heterogeneity [24, 38], potentially arising from differences in device brands and intervention durations (1–12 months); ? inadequate sample sizes, with most studies including fewer than 400 participants [15, 25, 30]; ? publication bias, as some systematic reviews were downgraded due to limited literature inclusion or asymmetric funnel plots [27, 30, 31].”

    From Effectiveness of Wearable Devices for Diabetes Management: An Overview of Systematic Reviews and Meta‐Analyses (2026) · cites this paper as [24]

    The Results (§3.3) report substantial heterogeneity for HbA1c (I² = 73%), supporting that part of the claim. But the Discussion (§4) says its source could not be identified, rather than attributing it to device brands or intervention durations. The paper does not identify inadequate sample sizes as a reason for downgrading evidence; its Results (§3.3) report symmetric funnel plots and no publication bias. (LLM, conf=0.87)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 17

  1. [2]Li Y. Teng D. Shi X. Prevalence of diabetes recorded in mainland China using 2018 diagnostic criteria from the American Diabetes Association: national cross sectional study BMJ (Clinical Research ed) 2020 369 10.1136/bmj.m997 PMC7186854 32345662 · DOI
  2. [4]Powers A. C. Type 1 diabetes mellitus: much progress, many opportunities Journal of Clinical Investigation 2021 131 8, article e142242 10.1172/jci142242 PMC8262558 33759815 · DOI
  3. [5]Nathan D. M. Genuth S. Lachin J. The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus The New England Journal of Medicine 1993 329 14 977 986 10.1056/NEJM199309303291401 2-s2.0-0027370108 8366922 · DOI · Paper page
  4. [6]Teo E. Hassan N. Tam W. Koh S. Effectiveness of continuous glucose monitoring in maintaining glycaemic control among people with type 1 diabetes mellitus: a systematic review of randomised controlled trials and meta-analysis Diabetologia 2022 65 4 604 619 10.1007/s00125-021-05648-4 35141761 · DOI · Paper page
  5. [7]American Diabetes Association 6. Glycemic targets: standards of medical care in diabetes-2019 Diabetes Care 2019 42 Supplement_1 S61 S70 10.2337/dc19-S006 2-s2.0-85058744744 30559232 · DOI · Paper page
  6. [10]Ajjan R. A. Abougila K. Bellary S. Sensor and software use for the glycaemic management of insulin-treated type 1 and type 2 diabetes patients Diabetes & Vascular Disease Research 2016 13 3 211 219 10.1177/1479164115624680 2-s2.0-84964402187 27000105 · DOI
  7. [13]Bosi E. Choudhary P. De Valk H. W. Efficacy and safety of suspend-before-low insulin pump technology in hypoglycaemia-prone adults with type 1 diabetes (SMILE): an open-label randomised controlled trial The Lancet Diabetes & endocrinology 2019 7 6 462 472 10.1016/S2213-8587(19)30150-0 2-s2.0-85065602628 31047902 · DOI
  8. [15]Dicembrini I. Pala L. Caliri M. Combined continuous glucose monitoring and subcutaneous insulin infusion versus self-monitoring of blood glucose with optimized multiple injections in people with type 1 diabetes: a randomized crossover trial Diabetes, Obesity & Metabolism 2020 22 8 1286 1291 10.1111/dom.14028 32166907 · DOI
  9. [17]Jensen M. H. Vestergaard P. Hirsch I. B. Hejlesen O. Use of personal continuous glucose monitoring device is associated with reduced risk of hypoglycemia in a 16-week clinical trial of people with type 1 diabetes using continuous subcutaneous insulin infusion Journal of Diabetes Science and Technology 2022 16 1 106 112 10.1177/1932296820957662 32945187 PMC8875036 · DOI
  10. [18]Laffel L. M. Kanapka L. G. Beck R. W. Effect of continuous glucose monitoring on glycemic control in adolescents and young adults with type 1 diabetes JAMA 2020 323 23 2388 2396 10.1001/jama.2020.6940 32543683 PMC7298603 · DOI · Paper page
  11. [19]Lind M. Polonsky W. Hirsch I. B. Continuous glucose monitoring vs conventional therapy for glycemic control in adults with type 1 diabetes treated with multiple daily insulin injections JAMA 2017 317 4 379 387 10.1001/jama.2016.19976 2-s2.0-85011930995 28118454 · DOI · Paper page
  12. [21]Thabit H. Prabhu J. N. Mubita W. Use of factory-calibrated real-time continuous glucose monitoring improves time in target and HbA1c in a multiethnic cohort of adolescents and young adults with type 1 diabetes: the millennials study Diabetes Care 2020 43 10 2537 2543 10.2337/dc20-0736 32723843 · DOI
  13. [23]Van Beers C. A. Devries J. H. Kleijer S. J. Continuous glucose monitoring for patients with type 1 diabetes and impaired awareness of hypoglycaemia (IN CONTROL): a randomised, open-label, crossover trial The Lancet Diabetes & Endocrinology 2016 4 11 893 902 10.1016/S2213-8587(16)30193-0 2-s2.0-84994173062 27641781 · DOI · Paper page
  14. [24]Zhang W. Liu Y. Sun B. Improved HbA1c and reduced glycaemic variability after 1-year intermittent use of flash glucose monitoring Scientific Reports 2021 11 1 p. 23950 10.1038/s41598-021-03480-9 34907285 PMC8671539 · DOI · Paper page
  15. [25]Adolfsson P. Parkin C. G. Thomas A. Krinelke L. G. Selecting the appropriate continuous glucose monitoring system - a practical approach European endocrinology 2018 14 1 24 29 10.17925/EE.2018.14.1.24 2-s2.0-85047184605 29922348 PMC5954591 · DOI
  16. [27]Szypowska A. Ramotowska A. Dzygalo K. Golicki D. Management of endocrine disease: beneficial effect of real-time continuous glucose monitoring system on glycemic control in type 1 diabetic patients: systematic review and meta-analysis of randomized trials European Journal of Endocrinology 2012 166 4 567 574 10.1530/EJE-11-0642 2-s2.0-84859400575 22096111 · DOI
  17. [29]Langendam M. Luijf Y. M. Hooft L. Continuous glucose monitoring systems for type 1 diabetes mellitus Cochrane Database of Systematic Reviews 2012 18 2 p. CD008101 10.1002/14651858.CD008101.pub2 2-s2.0-84862668643 PMC6486112 22258980 · DOI · Paper page

Authors
Wang, Y., Zou, C., Na, H., Zeng, W., & Li, X.
Affiliations
  • Hainan Medical University (CN)
  • Department of Endocrine, The First Affiliated Hospital of Hainan Medical University, Haikou, Hainan 570102, China
Corresponding author
Li, Xiaoyan
Venue
Computational and Mathematical Methods in Medicine
Publisher
Wiley
Published
2022-06-18
Volume
2022
Pages
1-9
ISSN
  • 1748-670X (ISSN-L)
  • 1748-6718
OpenAlex
W4283075106
Cited by
12
References
12
Citations by year
2026: 1 · 2025: 2 · 2024: 3 · 2023: 5 · 2022: 1
FWCI
0.39
Type
journal article
Language
en
Open access
Locations
  • Computational and Mathematical Methods in Medicine (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
Funders
Hainan Medical University
Topics
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
Keywords
type 1 diabetes, continuous glucose monitoring, self-monitoring of blood glucose, glycemic control, HbA1c, hypoglycemia, diabetic ketoacidosis
MeSH terms
Blood Glucose, Diabetes Mellitus, Type 1, Glucose, Humans, Hypoglycemia, Blood Glucose Self-Monitoring, Randomized Controlled Trials as Topic

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review