The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Performance evaluation for rapid detection of pan-cancer microsatellite instability with MANTIS
Open accessAbstract
// Esko A. Kautto 1 , Russell Bonneville 1 , Jharna Miya 1 , Lianbo Yu 2 , Melanie A. Krook 1 , Julie W. Reeser 1 and Sameek Roychowdhury 1,3 1 Comprehensive Cancer Center, The Ohio State University, Columbus, OH, USA 2 Department of Biomedical Informatics, The Ohio State University, Columbus, OH, USA 3 Division of Medical Oncology, Department of Internal Medicine, The Ohio State University, Columbus, OH, USA Correspondence to: Sameek Roychowdhury, email: // Keywords : microsatellite instability, computational biology, next-generation sequencing Received : November 24, 2016 Accepted : December 02, 2016 Published : December 12, 2016 Abstract In current clinical practice, microsatellite instability (MSI) and mismatch repair deficiency detection is performed with MSI-PCR and immunohistochemistry. Recent research has produced several computational tools for MSI detection with next-generation sequencing (NGS) data; however a comprehensive analysis of computational methods has not yet been performed. In this study, we introduce a new MSI detection tool, MANTIS, and demonstrate its favorable performance compared to the previously published tools mSINGS and MSISensor. We evaluated 458 normal-tumor sample pairs across six cancer subtypes, testing classification performance on variable numbers of target loci ranging from 10 to 2539. All three computational methods were found to be accurate, with MANTIS exhibiting the highest accuracy with 98.91% of samples from all six diseases classified correctly. MANTIS displayed superior performance among the three tools, having the highest overall sensitivity (MANTIS 97.18%, MSISensor 96.48%, mSINGS 76.06%) and specificity (MANTIS 99.68%, mSINGS 99.68%, MSISensor 98.73%) across six cancer types, even with loci panels of varying size. Additionally, MANTIS also had the lowest resource consumption (<1% of the space and <7% of the memory required by mSINGS) and fastest running times (49.6% and 8.7% of the running times of MSISensor and mSINGS, respectively). This study highlights the potential utility of MANTIS in classifying samples by MSI-status, allowing its incorporation into existing NGS pipelines.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Controlling the False Discovery Rate: A Practical and Powerful Approach to Multiple Testing
Benjamini, Y., & Hochberg, Y. (1995) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1995.tb02031.x · Cited by 109,482
The Sequence Alignment/Map format and SAMtools
Li, H., Handsaker, B., Wysoker, A., Fennell, T., Ruan, J., Homer, N., Marth, G., Abecasis, G., Durbin, R., & 1000 Genome Project Data Processing Subgroup (2009) · Bioinformatics · doi:10.1093/bioinformatics/btp352 · Cited by 62,041
Fast and accurate short read alignment with Burrows-Wheeler transform
Li, H., & Durbin, R. (2009) · Bioinformatics · doi:10.1093/bioinformatics/btp324 · Cited by 58,607
BEDTools: a flexible suite of utilities for comparing genomic features
Quinlan, A. R., & Hall, I. M. (2010) · Bioinformatics · doi:10.1093/bioinformatics/btq033 · Cited by 27,437
Initial sequencing and analysis of the human genome
International Human Genome Sequencing Consortium, Whitehead Institute for Biomedical Research, C. F. G. R., Lander, E. S., Linton, L. M., Birren, B., Nusbaum, C., Zody, M. C., Baldwin, J., Devon, K., Dewar, K., et al. (2001) · Nature · doi:10.1038/35057062 · Cited by 24,216
PD-1 Blockade in Tumors with Mismatch-Repair Deficiency
Le, D. T., Uram, J. N., Wang, H., Bartlett, B. R., Kemberling, H., Eyring, A. D., Skora, A. D., Luber, B. S., Azad, N. S., Laheru, D., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1500596 · Cited by 9,377
The cancer genome atlas pan-cancer analysis project
The Cancer Genome Atlas Research Network, Weinstein, J. N., Collisson, E. A., Mills, G. B., Shaw, K. R. M., Ozenberger, B. A., Ellrott, K., Shmulevich, I., Sander, C., & Stuart, J. M. (2013) · Nature Genetics · doi:10.1038/ng.2764 · Cited by 9,092 · cited 2×
“999808 Table S4 : The performance of mSINGS , MSISensor , and MANTIS over all 458 pairs from COAD / READ , UCEC , STAD , ESCA , UCS and PRAD .”
MethodComprehensive molecular characterization of human colon and rectal cancer
The Cancer Genome Atlas Network (2012) · Nature · doi:10.1038/nature11252 · Cited by 8,499
Comprehensive molecular characterization of gastric adenocarcinoma
The Cancer Genome Atlas Research Network (2014) · Nature · doi:10.1038/nature13480 · Cited by 6,498
Integrated genomic characterization of endometrial carcinoma
The Cancer Genome Atlas Research Network, & Levine, D. A. (2013) · Nature · doi:10.1038/nature12113 · Cited by 5,784
Cited by
Landscape of Microsatellite Instability Across 39 Cancer Types
Bonneville, R., Krook, M. A., Kautto, E. A., Miya, J., Wing, M. R., Chen, H.-Z., Reeser, J. W., Yu, L., & Roychowdhury, S. (2017) · JCO Precision Oncology · doi:10.1200/po.17.00073 · Cited by 1,476
Self-citationBaretti, M., & Le, D. T. (2018) · Pharmacology & Therapeutics · doi:10.1016/j.pharmthera.2018.04.004 · Cited by 556
Microsatellite instability: a review of what the oncologist should know
Li, K., Luo, H., Huang, L., Luo, H., & Zhu, X. (2020) · Cancer Cell International · doi:10.1186/s12935-019-1091-8 · Cited by 509
Middha, S., Zhang, L., Nafa, K., Jayakumaran, G., Wong, D., Kim, H. R., Sadowska, J., Berger, M. F., Delair, D. F., Shia, J., et al. (2017) · JCO Precision Oncology · doi:10.1200/po.17.00084 · Cited by 377
Evaluating Mismatch Repair Deficiency in Pancreatic Adenocarcinoma: Challenges and Recommendations
Hu, Z. I., Shia, J., Stadler, Z. K., Varghese, A. M., Capanu, M., Salo-Mullen, E., Lowery, M. A., Diaz, L. A., Mandelker, D., Yu, K. H., et al. (2018) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-17-3099 · Cited by 372
Mismatch Repair Pathway, Genome Stability and Cancer
Pećina-Šlaus, N., Kafka, A., Salamon, I., & Bukovac, A. (2020) · Frontiers in Molecular Biosciences · doi:10.3389/fmolb.2020.00122 · Cited by 278
CXCR4 inhibition in human pancreatic and colorectal cancers induces an integrated immune response
Biasci, D., Smoragiewicz, M., Connell, C. M., Wang, Z., Gao, Y., Thaventhiran, J. E. D., Basu, B., Magiera, L., Johnson, T. I., Bax, L., et al. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2013644117 · Cited by 262
Metadata
- Authors
- Kautto, E. A., Bonneville, R., Miya, J., Yu, L., Krook, M. A., Reeser, J. W., & Roychowdhury, S.
- Venue
- Oncotarget
- Publisher
- Impact Journals, LLC
- Published
- 2016-12-12
- Volume
- 8
- Issue
- 5
- Pages
- 7452-7463
- ISSN
- 1949-2553 (ISSN-L)
- OpenAlex
- W2567051070
- Cited by
- 316
- References
- 36
- FWCI
- 14.33
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.