CoChat

Comparison of Subgingival Bacterial Sampling With Oral Lavage for Detection and Quantification of Periodontal Pathogens by Real‐Time Polymerase Chain Reaction

Open access
Boutaga, Khalil, Savelkoul, Paul H.M., Winkel, Edwin G., van Winkelhoff, Arie J. · 2007 · Journal of Periodontology
Cited by 138

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Background: Saliva has been studied for the presence of subgingival pathogens in periodontitis patients. With the anaerobic culture technique, the discrepancy between salivary recovery and subgingival presence has been significant, which makes this approach not suitable for practical use in the microbial diagnosis of periodontitis patients. The real‐time polymerase chain reaction (PCR) technique represents a very sensitive technique to detect and quantify bacterial pathogens. The aim of the study was to compare the presence and numbers of Actinobacillus actinomycetemcomitans, Porphyromonas gingivalis, Tannerella forsythensis, Prevotella intermedia, and Micromonas micros in subgingival plaque and mouthwash samples by the anaerobic culture and real‐time PCR techniques. Methods: Pooled subgingival plaque samples and 10‐ml mouthwash samples were collected from 21 adult patients with periodontitis and analyzed by quantitative anaerobic culture and real‐time PCR for A. actinomycetemcomitans, P. gingivalis, T. forsythensis, P. intermedia, and M. micros. Results: The detection frequency of A. actinomycetemcomitans, P. gingivalis, and T. forsythensis in subgingival plaque was identical by culture and real‐time PCR and was higher for P. intermedia and M. micros by real‐time PCR. The highest detection frequencies for the target bacteria were found in mouthwash samples by real‐time PCR. The additional value of the real‐time PCR to detect target bacteria was 38% for P. gingivalis, 73% for T. forsythensis, 77% for P. intermedia, and 71% for M. micros. The sensitivity to detect target species in mouthwash by real‐time PCR was 100% for all test species except for P. intermedia (93.8%). Conclusions: Rapid detection and quantification of periodontal pathogens in mouthwash samples are possible by real‐time PCR. The procedure is significantly less time‐consuming than subgingival sampling with paper points. This approach to detect major periodontal pathogens in mouthwash samples may simplify microbial diagnosis in periodontitis patients and may be used to monitor periodontal treatment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1902/jop.2007.060078

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 138

Metadata

Authors
Boutaga, K., Savelkoul, P. H. M., Winkel, E. G., & van Winkelhoff, A. J.
Venue
Journal of Periodontology
Publisher
Wiley
Published
2007-01
Volume
78
Issue
1
Pages
79-86
ISSN
  • 0022-3492 (ISSN-L)
  • 1943-3670
OpenAlex
W2113739852
Cited by
138
References
2
FWCI
9.27
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.