CoChat

Transcatheter versus surgical aortic valve replacement in low and intermediate risk patients with severe aortic stenosis: systematic review and meta-analysis of randomized controlled trials and propensity score matching observational studies

Open access
Fu, Jintao, Popal, Mohammad Sharif, Li, Yulin, Li, Guoqi, Qi, Yue, Fang, Fang, Kwong, Joey S. W., You, Bin, Meng, Xu, Du, Jie · 2019 · Journal of Thoracic Disease
Cited by 31

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

BACKGROUND: To compare the outcome of transcatheter aortic valve replacement (TAVR) with surgical aortic valve replacement (SAVR) in low and intermediate risk patients with severe aortic stenosis (AS). Randomized controlled trials (RCT) and propensity score matching (PSM) studies compare TAVR with SAVR in patients at low and intermediate surgical risk. METHODS: Two authors searched relevant literature independently, then extracted data from the included studies, and assessed risk of bias and quality of study separately according to different study designs, besides that, the extracted data was analyzed via utilization of GRADE system to evaluate the quality of evidence separately. RESULTS: Overall 15 studies (5 RCTs, 10 PSM studies) with total 12,057 patients were selected. Mortality and disabling stroke during follow-up period were comparable between TAVR and SAVR (RR 1.09, 95% CI: 0.81 to 1.46; RR 0.7, 95% CI: 0.45 to 1.07, respectively), TAVR revealed to be superior to SAVR regarding acute kidney injury (AKI), and onset of new atrial fibrillation (AF) (RCT: high certainty; AKI in PSM: moderate certainty, AF in PSM: low certainty). These results of RCT and PSM studies are consistent. In RCT review, SAVR was better in the following aspects: aortic valve (AV) re-intervention (high certainty), vascular complications, pacemaker implantation (moderate certainty), but comparable in the following aspects: myocardial infarction (MI), aortic insufficient (AI) (moderate certainty), major bleeding (low certainty). In PSM review, SAVR revealed a better result in AI and vascular complications (high certainty), but in the aspects of AV re-intervention, pacemaker implantation, major bleeding and MI (low certainty), it was comparable. CONCLUSIONS: TAVR is comparable to SAVR in terms of mortality and disabling stroke in severe AS patients at low and intermediate risk, but higher proportion of AV re-intervention observed in TAVR. Those results should encourage caution when extending the indications of TAVR into low risk patients, especially for young low risk patients. SYSTEMATIC REVIEW REGISTRATION: PROSPERO CRD 42018112626.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.21037/jtd.2019.04.97

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

Metadata

Authors
Fu, J., Popal, M. S., Li, Y., Li, G., Qi, Y., Fang, F., Kwong, J. S. W., You, B., Meng, X., & Du, J.
Venue
Journal of Thoracic Disease
Published
2019-05
Volume
11
Issue
5
Pages
1945-1962
ISSN
  • 2072-1439 (ISSN-L)
  • 2077-6624
OpenAlex
W2946729909
Cited by
31
References
8
FWCI
0.97
Type
journal article
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.