Kinematics of the elbow.
The DOI matches its Crossref record.
Abstract
Previous studies of elbow kinematics produced conflicting results because of technical limitations. Kinematic analyses of eight normal elbows (four in cadavera and four in living subjects) using true lateral roentgenograms made by a special technique showed that flexion occurs about a single axis. This axis passes through the centers of the arcs outlined by the bottom of the trochlear sulcus and the periphery of the capitellum. Motion of the joint surfaces is of a sliding type except at the extremes of flexion and extension where rolling motion occurs. The carrying angle of the forearm remains constant as the elbow flexes. Based on these findings, total elbow prostheses ideally should be uniaxial, with the axis of flexion of the prosthesis the same as the axis of the normal joint.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Holzbaur, K. R. S., Murray, W. M., & Delp, S. L. (2005) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-3320-7 · Cited by 1,013
Developments in hardware systems of active upper-limb exoskeleton robots: A review
Gopura, R. A. R. C., Bandara, D. S. V., Kiguchi, K., & Mann, G. K. I. (2016) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2015.10.001 · Cited by 480
A Review on Design of Upper Limb Exoskeletons
Gull, M. A., Bai, S., & Bak, T. (2020) · Robotics · doi:10.3390/robotics9010016 · Cited by 435
Variation of muscle moment arms with elbow and forearm position
Murray, W. M., Delp, S. L., & Buchanan, T. S. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(94)00114-j · Cited by 385
Association Between an Aggrecan Gene Polymorphism and Lumbar Disc Degeneration
Kawaguchi, Y., Osada, R., Kanamori, M., Ishihara, H., Ohmori, K., Matsui, H., & Kimura, T. (1999) · Spine · doi:10.1097/00007632-199912010-00006 · Cited by 275
Mechanical designs of active upper-limb exoskeleton robots: State-of-the-art and design difficulties
Gopura, R. A. R. C., & Kiguchi, K. (2009) · 2009 IEEE International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2009.5209630 · Cited by 192
“It includes the elbow joint and the radioulnar joints [8], [10].”
BackgroundKinematics of human arm reconstructed from spatial tracking system recordings
Biryukova, E. V., Roby-Brami, A., Frolov, A. A., & Mokhtari, M. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00040-3 · Cited by 190
“The variation of F}Ee axis has been reported to be between 3}83 (London, 1981), 73 (Deland et al.”
BackgroundMethodSkeletal Muscle Mechanics: Implications for Rehabilitation
Lieber, R. L., & Bodine-Fowler, S. C. (1993) · Physical Therapy · doi:10.1093/ptj/73.12.844 · Cited by 183
Validity of Goniometric Elbow Measurements: Comparative Study with a Radiographic Method
Chapleau, J., Canet, F., Petit, Y., Laflamme, G.-Y., & Rouleau, D. M. (2011) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-011-1986-8 · Cited by 171
“the examiner placed and rotated the fully extended elbow to make the capitellum and trochlea appear as concentric circles to achieve a perfect lateral view of the elbow [17].”
Tissue-Engineering Approach to Regenerating the Intervertebral Disc
O'Halloran, D. M., & Pandit, A. S. (2007) · Tissue Engineering · doi:10.1089/ten.2005.0608 · Cited by 170
Bowles, R. D., Williams, R. M., Zipfel, W. R., & Bonassar, L. J. (2010) · Tissue Engineering Part A · doi:10.1089/ten.tea.2009.0442 · Cited by 165
An exoskeletal robot for human elbow motion support‐sensor fusion, adaptation, and control
Kiguchi, K., Kariya, S., Watanabe, K., Izumi, K., & Fukuda, T. (2001) · IEEE Transactions on Systems, Man and Cybernetics, Part B (Cybernetics) · doi:10.1109/3477.931520 · Cited by 159
Zhang, L., Butler, J., Nishida, T., Nuber, G., Huang, H., & Rymer, W. Z. (1998) · Journal of Biomechanical Engineering · doi:10.1115/1.2834754 · Cited by 26
Metadata
- Authors
- London, J. T.
- Venue
- The Journal of Bone & Joint Surgery
- Published
- 1981-04
- Volume
- 63
- Issue
- 4
- Pages
- 529-535
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W4321429533
- Cited by
- 261
- References
- 0
- FWCI
- 5.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.