Degradation and tissue replacement of an absorbable polyglycolide screw in the fixation of rabbit femoral osteotomies.
The DOI matches its Crossref record.
Abstract
Degradation and tissue replacement of a totally absorbable polyglycolide screw, 4.5 millimeters in diameter and thirty millimeters in length, were studied histologically, morphometrically, and radiographically at sequential stages of resorption at as long as thirty-six weeks after fixation of a transverse distal femoral osteotomy in rabbits. The initial mean shear force to failure was 95.0 newtons for the specimens that had been fixed with the polyglycolide screw compared with 257.0 newtons for the distal part of the contralateral, intact femur. The physical appearance of the screw was unaltered at three weeks. The first histological signs of degradation were seen at six weeks, along the thread ridge. Premature breakage of the screw resulted in gross displacement and non-union of the osteotomy in one animal. The degradation of polyglycolide was accompanied histologically by a typical non-specific foreign-body reaction. This kind of tissue response seemed to be associated with an osteolytic proximal expansion of the implant cavity that was suggestive of increased pressure within the cavity during degradation of the screw. In eight specimens, a wall of new bone formed around this area of osteolysis and demarcated the implant cavity from the surrounding normal cancellous bone. Seventy-four per cent of the periphery and 28 per cent of the central core of the screw had been resorbed at twelve weeks. At thirty-six weeks, no polymeric material could be discerned, and the predominant tissue component within the implant cavity was loose connective tissue. The volume fractions of trabecular bone and hematopoietic bone marrow were significantly lower (p less than 0.01) than those of the intact, control side, but the degree of restoration of tissue varied considerably from animal to animal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Biodegradable synthetic polymers for tissue engineering
CSIRO Molecular Science, B. 1., & Gunatillake, P. (2003) · European Cells and Materials · doi:10.22203/ecm.v005a01 · Cited by 1,765
Athanasiou, K. A., Niederauer, G. G., & Agrawal, C. M. (1996) · Biomaterials · doi:10.1016/0142-9612(96)85754-1 · Cited by 1,497
Biocompatibility of hydrogel-based scaffolds for tissue engineering applications
Naahidi, S., Jafari, M., Logan, M., Wang, Y., Yuan, Y., Bae, H., Dixon, B., & Chen, P. (2017) · Biotechnology Advances · doi:10.1016/j.biotechadv.2017.05.006 · Cited by 907
Clinical biocompatibility of biodegradable orthopaedic implants for internal fixation: a review
Böstman, O., & Pihlajamäki, H. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00129-0 · Cited by 509
Self-citationAdverse Tissue Reactions to Bioabsorbable Fixation Devices
B??stman, O. M., & Pihlajam??ki, H. K. (2000) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200002000-00026 · Cited by 476
Self-citationRecent developments in biodegradable synthetic polymers
Gunatillake, P., Mayadunne, R., & Adhikari, R. (2006) · Biotechnology Annual Review · doi:10.1016/s1387-2656(06)12009-8 · Cited by 444
Ignatius, A. A., & Claes, L. E. (1996) · Biomaterials · doi:10.1016/0142-9612(96)81421-9 · Cited by 426
Bioabsorbable fixation in orthopaedic surgery and traumatology
Rokkanen, P. U., Böstman, O., Hirvensalo, E., Mäkelä, E. A., Partio, E. K., Pätiälä, H., Vainionpää, S., Vihtonen, K., & Törmälä, P. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00128-9 · Cited by 382
Self-citationBiodegradable magnesium implants for orthopedic applications
Waizy, H., Seitz, J.-M., Reifenrath, J., Weizbauer, A., Bach, F.-W., Meyer-Lindenberg, A., Denkena, B., & Windhagen, H. (2013) · Journal of Materials Science · doi:10.1007/s10853-012-6572-2 · Cited by 297
Bergsma, J. E., Rozema, F. R., Bos, R. R. M., Boering, G., de Bruijn, W. C., & Pennings, A. J. (1995) · Biomaterials · doi:10.1016/0142-9612(95)93253-a · Cited by 247
Pre-clinical in vivo evaluation of orthopaedic bioabsorbable devices
An, Y. H., Woolf, S. K., & Friedman, R. J. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00132-0 · Cited by 224
Kenley, R., Marden, L., Turek, T., Jin, L., Ron, E., & Hollinger, J. O. (1994) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820281004 · Cited by 183
Absorbable polyglycolide devices in trauma and bone surgery
Ashammakhi, N., & Rokkanen, P. (1997) · Biomaterials · doi:10.1016/s0142-9612(96)00107-x · Cited by 166
Self-citationBiomaterials-Driven Sterile Inflammation
Chen, H., Agrawal, D. K., & Thankam, F. G. (2022) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2020.0253 · Cited by 41
“119 Although the temporal and spatial degradation of PGA implants were uniform in an in vivo study in rabbits, it was found that the tissue response was inconsistent.”
Metadata
- Authors
- Böstman, O., Päivärinta, U., Partio, E., Vasenius, J., Manninen, M., & Rokkanen, P.
- Venue
- The Journal of Bone & Joint Surgery
- Published
- 1992-08
- Volume
- 74
- Issue
- 7
- Pages
- 1021-1031
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W2205427322
- Cited by
- 118
- References
- 0
- FWCI
- 3.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.