Isolation and characterization of debris in membranes around total joint prostheses.

Margevicius, K J, Bauer, T W, McMahon, J T, Brown, S A, Merritt, K·1994·The Journal of Bone & Joint Surgery

Abstract

Particles of wear debris have been implicated in osteolysis around and aseptic loosening of total joint prostheses, but the number and size distribution of particles present in periprosthetic tissues are unknown. A method of particle assay was developed, consisting of nitric-acid digestion of tissue followed by collection of particles, electronic quantitation, and parallel morphological and chemical characterization. Nitric acid had minimum deleterious effects on control samples of titanium, cobalt-chromium alloy, and polyethylene particles, as determined by atomic absorption spectroscopy, scanning electron microscopy, and electronic measurements of the sizes of the particles. Acid digestion of twelve control samples of tissue, including tissue rich in hemosiderin, resulted in particle counts that were no higher than that in the digestion solution background. Other digestion preparations, including hydrochloric acid and sodium hypophosphate, were not as effective as nitric acid. With the low size limit of detection of approximately 0.58 micrometer, particle analysis of tissue adjacent to twenty retrieved total joint implants indicated a range of concentration of 0.85 to 141.85 x 10(9) particles per gram of tissue (dry weight). Although a few particles of more than 100 micrometers were detected, the mode of particle diameter from each sample ranged from the lower limit of detection (approximately 0.58 micrometer) to 0.79 micrometer. The findings of morphological studies and x-ray spectroscopy of isolated particles corresponded with those of light microscopy of the fibrous membranes. These data indicate that most of the particles in implant membranes are smaller than the resolution of the light microscope and that tissue digestion is necessary for quantitation and characterization.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2106/00004623-199411000-00010

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 17 references

Cited by

See all 270

Metadata

Authors
Margevicius, K. J., Bauer, T. W., McMahon, J. T., Brown, S. A., & Merritt, K.
Venue
The Journal of Bone & Joint Surgery
Published
1994-11
Volume
76
Issue
11
Pages
1664-1675
ISSN
0021-9355 (ISSN-L)
OpenAlex
W79229496
Cited by
270
References
17
FWCI
14.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Isolation and characterization of debris in membranes around total joint prostheses. https://app.cochat.ai/papers/10.2106/00004623-199411000-00010
The paper
Margevicius, K. J., Bauer, T. W., McMahon, J. T., Brown, S. A., & Merritt, K. (1994). Isolation and characterization of debris in membranes around total joint prostheses. The Journal of Bone & Joint Surgery. https://doi.org/10.2106/00004623-199411000-00010

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.