Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 307

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

Isolation and characterization of wear particles generated in patients who have had failure of a hip arthroplasty without cement.

Maloney, W J, Smith, R L, Schmalzried, T P, Chiba, J, Huene, D, Rubash, H·1995·The Journal of Bone & Joint Surgery

Abstract

Wear particles from thirty-five membranes obtained during revision hip-replacement operations were studied after digestion of the soft tissue with papain. The particles were isolated and were characterized with use of light and scanning electron microscopic techniques, x-ray microanalysis, and an automated particle analyzer. The mean size of the polyethylene particles was 0.5 micrometer, and the metal particles were a mean of 0.7 micrometer, as determined with scanning electron microscopy. The automated particle analyzer revealed a mean particle diameter of 0.63 micrometer (more than 90 per cent of all particles were less than 0.95 micrometer) and a mean of 1.7 billion particles per gram of tissue, compared with only 143 million per gram of tissue for the control samples. X-ray microanalysis revealed metal debris in sixteen (46 per cent) of the thirty-five membranes after digestion. Thirteen (50 per cent) of the twenty-six membranes surrounding a titanium-alloy stem contained metal particles, compared with three of the nine membranes surrounding a chromium-cobalt stem. Metal debris was present in only one of the twelve membranes surrounding a titanium-alloy stem without a porous coating, compared with twelve of the fourteen membranes surrounding a titanium-alloy stem with a porous coating. This tenfold difference in prevalence was significant (p < 0.005). On the average, the total number of particles (expressed in millions per gram of tissue) associated with the bipolar acetabular components was twice that associated with the fixed acetabular components. In addition, there was a trend toward a larger mean size of the polyethylene particles in association with the bipolar cups. Our data indicate that particulate prosthetic debris in the tissues around failed femoral components that have been inserted without cement constitutes a class of particles that are predominantly less than one micrometer in size and are present in amounts of more than one billion particles per gram of tissue. Routine histological methods did not detect this class of wear debris and led to a gross underestimation of the amount of debris in these membranes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2106/00004623-199509000-00002

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 18 references

Cited by

See all 307

Metadata

Authors
Maloney, W. J., Smith, R. L., Schmalzried, T. P., Chiba, J., Huene, D., & Rubash, H.
Venue
The Journal of Bone & Joint Surgery
Published
1995-09
Volume
77
Issue
9
Pages
1301-1310
ISSN
0021-9355 (ISSN-L)
OpenAlex
W1908176107
Cited by
307
References
18
FWCI
12.91
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Isolation and characterization of wear particles generated in patients who have had failure of a hip arthroplasty without cement. https://app.cochat.ai/papers/10.2106/00004623-199509000-00002
The paper
Maloney, W. J., Smith, R. L., Schmalzried, T. P., Chiba, J., Huene, D., & Rubash, H. (1995). Isolation and characterization of wear particles generated in patients who have had failure of a hip arthroplasty without cement. The Journal of Bone & Joint Surgery. https://doi.org/10.2106/00004623-199509000-00002

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.