Kinematically Versus Mechanically Aligned Total Knee Arthroplasty
Abstract
The purpose of this study was to compare 2 alignment methods for total knee arthroplasty (TKA): kinematic alignment with the use of patient-specific guides and mechanical alignment with conventional instruments. A randomized, controlled trial of 41 kinematically aligned and 41 mechanically aligned patients was conducted with the patient, radiographic evaluator, and clinical evaluator blinded to the alignment technique. Radiographic measurements were made from long-leg computer tomography scanograms. Clinical outcome scores and motion were measured preoperatively and 6 months postoperatively. The hip–knee–ankle angle (0.3° difference; P =.693) and anatomic angle of the knee (0.8° difference; P =.131) were similar for both groups. In the kinematically aligned group, the angle of the femoral component was 2.4° more valgus ( P <.000) and the angle of the tibial component was 2.3° more varus ( P <.000) than the mechanically aligned group. At 6 months postoperatively, the Western Ontario and McMaster Universities Osteoarthritis Index score was 16 points better ( P <.000), Oxford Score was 7 points better ( P =.001), combined Knee Society Score was 25 points better ( P =.001), and flexion was 5.0° greater ( P =.043) in the kinematically aligned group than in the mechanically aligned group. Our findings suggest that the risk of early failure related to limb or knee alignment should be similar in kinematic and mechanically aligned TKA. More anatomic alignment of the implant was associated with better flexion and better clinical outcome scores in the kinematically aligned group.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Patient Satisfaction after Total Knee Arthroplasty: Who is Satisfied and Who is Not?
Bourne, R. B., Chesworth, B. M., Davis, A. M., Mahomed, N. N., & Charron, K. D. J. (2010) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-009-1119-9 · Cited by 2,569
Coronal alignment after total knee replacement
Jeffery, R., Morris, R., & Denham, R. (1991) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.73b5.1894655 · Cited by 1,100
Bellemans, J., Colyn, W., Vandenneucker, H., & Victor, J. (2012) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-011-1936-5 · Cited by 1,085
Baker, P. N., van der Meulen, J. H., Lewsey, J., & Gregg, P. J. (2007) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.89b7.19091 · Cited by 975
Coronal Alignment in Total Knee Arthroplasty
Fang, D. M., Ritter, M. A., & DAVIS, K. E. (2009) · The Journal of Arthroplasty · doi:10.1016/j.arth.2009.04.034 · Cited by 658
The Axes of Rotation of the Knee
HOLLISTER, A. M., JATANA, S., SINGH, A. K., SULLIVAN, W. W., & LUPICHUK, A. G. (1993) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199305000-00033 · Cited by 502
Matziolis, G., Krocker, D., Weiss, U., Tohtz, S., & Perka, C. (2007) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200702000-00002 · Cited by 429
Total Joint Arthroplasty of the Knee
Hungerford, D. S., & Krackow, K. A. (1985) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198501000-00004 · Cited by 306
THREE-DIMENSIONAL MECHANICS, KINEMATICS, AND MORPHOLOGY OF THE KNEE VIEWED IN VIRTUAL REALITY
ECKHOFF, D. G., BACH, J. M., SPITZER, V. M., REINIG, K. D., BAGUR, M. M., BALDINI, T. H., & FLANNERY, N. M. P. (2005) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200511002-00009 · Cited by 293
Howell, S. M., Kuznik, K., Hull, M. L., & Siston, R. A. (2008) · Orthopedics · doi:10.3928/01477447-20080901-15 · Cited by 288
Cited by
Howell, S. M., Howell, S. J., Kuznik, K. T., Cohen, J., & Hull, M. L. (2013) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-012-2613-z · Cited by 495
Alignment options for total knee arthroplasty: A systematic review
Rivière, C., Iranpour, F., Auvinet, E., Howell, S., Vendittoli, P.-A., Cobb, J., & Parratte, S. (2017) · Orthopaedics & Traumatology: Surgery & Research · doi:10.1016/j.otsr.2017.07.010 · Cited by 463
Dossett, H. G., Estrada, N. A., Swartz, G. J., LeFevre, G. W., & Kwasman, B. G. (2014) · The Bone & Joint Journal · doi:10.1302/0301-620x.96b7.32812 · Cited by 431
Self-citationHowell, S. M., Papadopoulos, S., Kuznik, K. T., & Hull, M. L. (2013) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-013-2621-x · Cited by 366
Patient dissatisfaction following total knee replacement: a growing concern?
Nam, D., Nunley, R. M., & Barrack, R. L. (2014) · The Bone & Joint Journal · doi:10.1302/0301-620x.96b11.34152 · Cited by 364
Metadata
- Authors
- Dossett, H. G., Swartz, G. J., Estrada, N. A., LeFevre, G. W., & Kwasman, B. G.
- Venue
- Orthopedics
- Publisher
- SLACK, Inc.
- Published
- 2012-02
- Volume
- 35
- Issue
- 2
- Pages
- e160-9
- ISSN
- 0147-7447 (ISSN-L)
- 1938-2367
- OpenAlex
- W2053850309
- Cited by
- 264
- References
- 17
- FWCI
- 13.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Kinematically Versus Mechanically Aligned Total Knee Arthroplasty. https://app.cochat.ai/papers/10.3928/01477447-20120123-04
- The paper
- Dossett, H. G., Swartz, G. J., Estrada, N. A., LeFevre, G. W., & Kwasman, B. G. (2012). Kinematically Versus Mechanically Aligned Total Knee Arthroplasty. Orthopedics. https://doi.org/10.3928/01477447-20120123-04
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.