Fluorescence of Bacteria, Pollens, and Naturally Occurring Airborne Particles: Excitation/Emission Spectra
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The fluorescence intensity as a function of excitation and emission wavelengths (EEM spectra) was measured for different species of bacteria, biochemical constituents of cells, pollens, and vegetation. This report documents these spectra. This endeavor is part of an effort to determine useful fluorescence excitation and emission wavelengths for discrimination between biological and nonbiological particles, and among different types of biological particles. These results can assist researchers in selecting excitation and emission wavelength bands that allow partial discrimination among particle types. The EEM spectra of dry bacteria samples are different from spectra of bacteria in liquid suspensions. In the dry samples more of the emission tends to occur at longer wavelengths. We discuss appropriate excitation sources for detecting bioaerosols using autofluorescence.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pan, Y.-L., Holler, S., Chang, R. K., Hill, S. C., Pinnick, R. G., Niles, S., & Bottiger, J. R. (1999) · Optics Letters · doi:10.1364/ol.24.000116 · Cited by 111 · cited 1×
“) can have a large effect on the fluorescence of a sample (25, 27, 29).”
BackgroundSelf-citation
Cited by
Autofluorescence of atmospheric bioaerosols – fluorescent biomolecules and potential interferences
Pöhlker, C., Huffman, J. A., & Pöschl, U. (2012) · Atmospheric Measurement Techniques · doi:10.5194/amt-5-37-2012 · Cited by 394
“In contrast to NAD(P)H, only the oxidized form of flavins is fluorescent and shows light emission at∼525 nm when excited at∼450 nm, although excitation has also been observed at∼280 nm and∼380 nm (Hill et al., 2009).”
BackgroundInfluentialReal-time sensing of bioaerosols: Review and current perspectives
Huffman, J. A., Perring, A. E., Savage, N. J., Clot, B., Crouzy, B., Tummon, F., Shoshanim, O., Damit, B., Schneider, J., Sivaprakasam, V., et al. (2020) · Aerosol Science and Technology · doi:10.1080/02786826.2019.1664724 · Cited by 299
Self-citationAutofluorescence of atmospheric bioaerosols: spectral fingerprints and taxonomic trends of pollen
Pöhlker, C., Huffman, J. A., Förster, J.-D., & Pöschl, U. (2013) · Atmospheric Measurement Techniques · doi:10.5194/amt-6-3369-2013 · Cited by 128
“One reason is that the fluorescence properties of biological and nonbiological materials are not separated by a clear offset, but rather show overlapping properties (Hill et al., 2009; Huffman et al., 2012).”
BackgroundMethodResultInfluentialSchumacher, C. J., Pöhlker, C., Aalto, P., Hiltunen, V., Petäjä, T., Kulmala, M., Pöschl, U., & Huffman, J. A. (2013) · Atmospheric Chemistry and Physics · doi:10.5194/acp-13-11987-2013 · Cited by 98
“The ultraviolet aerodynamic particle sizer (UV-APS; TSI, Shoreview, MN, USA) and the wideband integrated bioaerosol sensor (WIBS; Droplet Measurement Technologies, Boulder, CO, USA) both characterize biological particles in real time based on the intensity of fluorescence emission from individual particles after pulse…”
BackgroundThe fluorescence properties of aerosol larger than 0.8 μm in urban and tropical rainforest locations
Gabey, A. M., Stanley, W. R., Gallagher, M. W., & Kaye, P. H. (2011) · Atmospheric Chemistry and Physics · doi:10.5194/acp-11-5491-2011 · Cited by 97
Metadata
- Authors
- Hill, S. C., Mayo, M. W., & Chang, R. K.
- Publisher
- Defense Technical Information Center
- Published
- 2009-02-01
- OpenAlex
- W1937831751
- Cited by
- 52
- References
- 1
- Type
- report
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.