Microphysiological systems in early stage drug development: Perspectives on current applications and future impact
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Microphysiological systems (MPS) are making advances to provide more standardized and predictive physiologically relevant responses to test articles in living tissues and organ systems. The excitement surrounding the potential of MPS to better predict human responses to medicines and improving clinical translation is overshadowed by their relatively slow adoption by the pharmaceutical industry and regulators. Collaboration between multiorganizational consortia and regulators is necessary to build an understanding of the strengths and limitations of MPS models and closing the current gaps. Here, we review some of the advances in MPS research, focusing on liver, intestine, vascular system, kidney and lung and present examples highlighting the context of use for these systems. For MPS to gain a foothold in drug development, they must have added value over existing approaches. Ideally, the application of MPS will augment in vivo studies and reduce the use of animals via tiered screening with less reliance on exploratory toxicology studies to screen compounds. Because MPS support multiple cell types (e.g. primary or stem-cell derived cells) and organ systems, identifying when MPS are more appropriate than simple 2D in vitro models for understanding physiological responses to test articles is necessary. Once identified, MPS models require qualification for that specific context of use and must be reproducible to allow future validation. Ultimately, the challenges of balancing complexity with reproducibility will inform the promise of advancing the MPS field and are critical for realization of the goal to reduce, refine and replace (3Rs) the use of animals in nonclinical research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Concordance of the toxicity of pharmaceuticals in humans and in animals
Olson, H., Betton, G., Robinson, D., Thomas, K., Monro, A., Kolaja, G., Lilly, P., Sanders, J., Sipes, G., Bracken, W., et al. (2000) · Regulatory Toxicology and Pharmacology · doi:10.1006/rtph.2000.1399 · Cited by 2,050 · cited 3×
“When information is combined from two toxicology species, animal data yield 70% concordance in uncovering toxicities seen in humans (Olson et al., 2000).”
InfluentialRapid casting of patterned vascular networks for perfusable engineered three-dimensional tissues
Miller, J. S., Stevens, K. R., Yang, M. T., Baker, B. M., Nguyen, D.-H. T., Cohen, D. M., Toro, E., Chen, A. A., Galie, P. A., Yu, X., et al. (2012) · Nature Materials · doi:10.1038/nmat3357 · Cited by 1,917
Kim, H. J., Huh, D., Hamilton, G., & Ingber, D. E. (2012) · Lab on a Chip · doi:10.1039/c2lc40074j · Cited by 1,734
Microscale culture of human liver cells for drug development
Khetani, S. R., & Bhatia, S. N. (2008) · Nature Biotechnology · doi:10.1038/nbt1361 · Cited by 1,219 · cited 1×
“As an example, albumin secretion, urea synthesis and cytochrome P450 expression were enhanced by coculturing primary human hepatocytes with stromal cells ( Khetani and Bhatia, 2008 ) or with endothelial cells ( Liu et al., 2014 ).”
A Human Disease Model of Drug Toxicity–Induced Pulmonary Edema in a Lung-on-a-Chip Microdevice
Huh, D., Leslie, D. C., Matthews, B. D., Fraser, J. P., Jurek, S., Hamilton, G. A., Thorneloe, K. S., McAlexander, M. A., & Ingber, D. E. (2012) · Science Translational Medicine · doi:10.1126/scitranslmed.3004249 · Cited by 993 · cited 1×
“Earlier versions of the lung-chip model have been utilized in several experiments including drug toxicityinduced pulmonary edema (Huh et al., 2012), evaluation of metabolic activity and cytokine secretion by physical stimuli (Stucki et al., 2015), asthma and chronic obstructive pulmonary disease…”
Kim, H. J., Li, H., Collins, J. J., & Ingber, D. E. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1522193112 · Cited by 922
Engineering of functional, perfusable 3D microvascular networks on a chip
Kim, S., Lee, H., Chung, M., & Jeon, N. L. (2013) · Lab on a Chip · doi:10.1039/c3lc41320a · Cited by 872 · cited 1×
“…in microfl uidic channels and VEGF and other angiogenic factors were introduced in a fi brin-collagen gel, in which HUVECs autonomously invaded the gel structure to create a hollow lumen, while leaving an opening at the interface of microfl uidic channels ( Kim et al., 2013 ; Yeon et al., 2012 ).”
Park, S. E., Georgescu, A., & Huh, D. (2019) · Science · doi:10.1126/science.aaw7894 · Cited by 847
Human 3D vascularized organotypic microfluidic assays to study breast cancer cell extravasation
Jeon, J. S., Bersini, S., Gilardi, M., Dubini, G., Charest, J. L., Moretti, M., & Kamm, R. D. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1417115112 · Cited by 723 · cited 1×
“…number of studies with co-culturing target cells in the vascular network have been reported for evaluating cancer cell extravasation ( Boussommier-Calleja et al., 2019 ; Chen et al., 2017 ; Jeon et al., 2015 ) and permeability of the blood-brain barrier ( Bang et al., 2017 ; Campisi et al., 2018 ).”
Campisi, M., Shin, Y., Osaki, T., Hajal, C., Chiono, V., & Kamm, R. D. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.07.014 · Cited by 718
Cited by
A guide to the organ-on-a-chip
Leung, C. M., de Haan, P., Ronaldson-Bouchard, K., Kim, G.-A., Ko, J., Rho, H. S., Chen, Z., Habibovic, P., Jeon, N. L., Takayama, S., et al. (2022) · Nature Reviews Methods Primers · doi:10.1038/s43586-022-00118-6 · Cited by 1,116
Towards in vitro models for reducing or replacing the use of animals in drug testing
Stresser, D. M., Kopec, A. K., Hewitt, P., Hardwick, R. N., Van Vleet, T. R., Mahalingaiah, P. K. S., O’Connell, D., Jenkins, G. J., David, R., Graham, J., et al. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-023-01154-7 · Cited by 94
Self-citationHuang, Y.-H., Watanabe, M., Yamashita, T., & Sudo, R. (2025) · Biofabrication · doi:10.1088/1758-5090/adc8d4 · Cited by 3
Metadata
- Authors
- Kopec, A. K., Yokokawa, R., Khan, N., Horii, I., Finley, J. E., Bono, C. P., Donovan, C., Roy, J., Harney, J., Burdick, A. D., Jessen, B., Lu, S., Collinge, M., Sadeghian, R. B., Derzi, M., Tomlinson, L., & Burkhardt, J. E.
- Venue
- The Journal of Toxicological Sciences
- Publisher
- Japanese Society of Toxicology
- Published
- 2021
- Volume
- 46
- Issue
- 3
- Pages
- 99-114
- ISSN
- 0388-1350 (ISSN-L)
- 1880-3989
- OpenAlex
- W3135830477
- Cited by
- 39
- References
- 26
- FWCI
- 1.82
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microphysiological systems in early stage drug development: Perspectives on current applications and future impact. https://app.cochat.ai/papers/10.2131/jts.46.99
- The paper
- Kopec, A. K., Yokokawa, R., Khan, N., Horii, I., Finley, J. E., Bono, C. P., Donovan, C., Roy, J., Harney, J., Burdick, A. D., Jessen, B., Lu, S., Collinge, M., Sadeghian, R. B., Derzi, M., Tomlinson, L., & Burkhardt, J. E. (2021). Microphysiological systems in early stage drug development: Perspectives on current applications and future impact. The Journal of Toxicological Sciences. https://doi.org/10.2131/jts.46.99
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.