Automated Gas Chromatographic System for Rapid Analysis of the Atmospheric Trace Gases Methane, Carbon Dioxide, and Nitrous Oxide
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
To study the fluxes of the radiative active trace gases CH 4, CO 2, and N 2 O, a gas sampling and analytical device was developed. It is a useful tool for accurate gas sampling in the field and enables the subsequent fully automated analysis of the gas samples in the laboratory. The computer‐controlled analytical system consists of a gas chromatograph equipped with a flame ionization detector (FID), an electron capture detector (ECD), and a pressure‐controlled autosampler for 64 sample containers. The system automates sample injection, the analysis of CH 4, CO 2, and N 2 O in each sample and the subsequent evacuation of the sample containers. It is equipped with a second alternative sample inlet for manual syringe injection. This inlet is suitable for analyzing small volumes of gas samples (3 mL). The gas sampling system for use in the field consists of evacuated sample bottles (100 mL) with Teflon cocks combined with a small battery‐driven field sampler with a pressure sensor. This device enables an on‐site control of the vacuum integrity of the sample bottles during sampling and purging of the dead volumes between the sampler induction pipe and the sample container.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bronson, K. F., & Mosier, A. R. (1993) · ASA Special Publications · doi:10.2134/asaspecpub55.c9 · Cited by 103
Cited by
Harter, J., Krause, H.-M., Schuettler, S., Ruser, R., Fromme, M., Scholten, T., Kappler, A., & Behrens, S. (2014) · The ISME Journal · doi:10.1038/ismej.2013.160 · Cited by 679
“The gas chromatograph setup and configuration have been described in detail previously (Loftfield et al., 1997).”
MethodRuser, R., Flessa, H., Russow, R., Schmidt, G., Buegger, F., & Munch, J. C. (2006) · Soil Biology and Biochemistry · doi:10.1016/j.soilbio.2005.05.005 · Cited by 586
Self-citationInfluence of biochar on drought tolerance of Chenopodium quinoa willd and on soil-plant relations
Kammann, C. I., Linsel, S., Gößling, J. W., & Koyro, H.-W. (2011) · Plant and Soil · doi:10.1007/s11104-011-0771-5 · Cited by 425
“scheme after Mosier and Mack 1980) and an automated sample-injection unit for syringes (Loftfield et al. 1997).”
MethodCastaldi, S., Riondino, M., Baronti, S., Esposito, F. R., Marzaioli, R., Rutigliano, F. A., Vaccari, F. P., & Miglietta, F. (2011) · Chemosphere · doi:10.1016/j.chemosphere.2011.08.031 · Cited by 338
“A modified system from Loftfield et al. (1997) was set up to analyze N2O and CH4 on the same gas sample.”
MethodKammann, C., Ratering, S., Eckhard, C., & Müller, C. (2012) · Journal of Environmental Quality · doi:10.2134/jeq2011.0132 · Cited by 331
Metadata
- Authors
- Loftfield, N., Flessa, H., Augustin, J., & Beese, F.
- Venue
- Journal of Environmental Quality
- Publisher
- Wiley
- Published
- 1997-03
- Volume
- 26
- Issue
- 2
- Pages
- 560-564
- ISSN
- 0047-2425 (ISSN-L)
- 1537-2537
- OpenAlex
- W2065828931
- Cited by
- 344
- References
- 1
- FWCI
- 4.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.