Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 294

The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.

A New Method for Detection and Quantification of Heartbeat Parameters in Drosophila, Zebrafish, and Embryonic Mouse Hearts

Open access
Fink, Martin, Callol-Massot, Carles, Chu, Angela, Ruiz-Lozano, Pilar, Belmonte, Juan Carlos Izpisua, Giles, Wayne, Bodmer, Rolf, Ocorr, Karen · 2009 · BioTechniques

Abstract

The genetic basis of heart development is remarkably conserved from Drosophila to mammals, and insights from flies have greatly informed our understanding of vertebrate heart development. Recent evidence suggests that many aspects of heart function are also conserved and the genes involved in heart development also play roles in adult heart function. We have developed a Drosophila heart preparation and movement analysis algorithm that allows quantification of functional parameters. Our methodology combines high-speed optical recording of beating hearts with a robust, semi-automated analysis to accurately detect and quantify, on a beat-to-beat basis, not only heart rate but also diastolic and systolic intervals, systolic and diastolic diameters, percent fractional shortening, contraction wave velocity, and cardiac arrhythmicity. Here, we present a detailed analysis of hearts from adult Drosophila, 2-3-day-old zebrafish larva, and 8-day-old mouse embryos, indicating that our methodology is potentially applicable to an array of biological models. We detect progressive age-related changes in fly hearts as well as subtle but distinct cardiac deficits in Tbx5 heterozygote mutant zebrafish. Our methodology for quantifying cardiac function in these genetically tractable model systems should provide valuable insights into the genetics of heart function.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2144/000113078

Cites

36 of 36 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 36 references

Cited by

See all 294

Metadata

Authors
Fink, M., Callol-Massot, C., Chu, A., Ruiz-Lozano, P., Belmonte, J. C. I., Giles, W., Bodmer, R., & Ocorr, K.
Venue
BioTechniques
Published
2009-02
Volume
46
Issue
2
Pages
101-113
ISSN
  • 0736-6205 (ISSN-L)
  • 1940-9818
OpenAlex
W2098324477
Cited by
294
References
36
FWCI
6.36
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A New Method for Detection and Quantification of Heartbeat Parameters in Drosophila, Zebrafish, and Embryonic Mouse Hearts. https://app.cochat.ai/papers/10.2144/000113078
The paper
Fink, M., Callol-Massot, C., Chu, A., Ruiz-Lozano, P., Belmonte, J. C. I., Giles, W., Bodmer, R., & Ocorr, K. (2009). A New Method for Detection and Quantification of Heartbeat Parameters in Drosophila, Zebrafish, and Embryonic Mouse Hearts. BioTechniques. https://doi.org/10.2144/000113078

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.